Tracking Regional Tissue Volume and Function Change in Lung Using Image Registration

We have previously demonstrated the 24-hour redistribution and reabsorption of bronchoalveolar lavage (BAL) fluid delivered to the lung during a bronchoscopic procedure in normal volunteers. In this work we utilize image-matching procedures to correlate fluid redistribution and reabsorption to changes in regional lung function. Lung CT datasets from six human subjects were used in this study. Each subject was scanned at four time points before and after BAL procedure. Image registration was performed to align images at different time points and different inflation levels. The resulting dense displacement fields were utilized to track tissue volume changes and reveal deformation patterns of local parenchymal tissue quantitatively. The registration accuracy was assessed by measuring landmark matching errors, which were on the order of 1 mm. The results show that quantitative-assessed fluid volume agreed well with bronchoscopist-reported unretrieved BAL volume in the whole lungs (squared linear correlation coefficient was 0.81). The average difference of lung tissue volume at baseline and after 24 hours was around 2%, which indicates that BAL fluid in the lungs was almost absorbed after 24 hours. Regional lung-function changes correlated with the presence of BAL fluid, and regional function returned to baseline as the fluid was reabsorbed.

[1]  Milan Sonka,et al.  Automated segmentation of pulmonary vascular tree from 3D CT images , 2004, SPIE Medical Imaging.

[2]  U. Hannemann,et al.  Changes in pulmonary mechanics after fiberoptic bronchoalveolar lavage in mechanically ventilated patients , 1998, Intensive Care Medicine.

[3]  E. Hoffman,et al.  Mass preserving nonrigid registration of CT lung images using cubic B-spline. , 2009, Medical physics.

[4]  Gary E. Christensen,et al.  Consistent image registration , 2001, IEEE Transactions on Medical Imaging.

[5]  Jorge Nocedal,et al.  A Limited Memory Algorithm for Bound Constrained Optimization , 1995, SIAM J. Sci. Comput..

[6]  Tunc Geveci,et al.  Advanced Calculus , 2014, Nature.

[7]  Wei Lu,et al.  Tracking lung tissue motion and expansion/compression with inverse consistent image registration and spirometry. , 2007, Medical physics.

[8]  Eric A. Hoffman,et al.  Registration-based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation , 2008, Medical Image Anal..

[9]  Gary E. Christensen,et al.  Unifying Vascular Information in Intensity-Based Nonrigid Lung CT Registration , 2010, WBIR.

[10]  Alejandro F. Frangi,et al.  Muliscale Vessel Enhancement Filtering , 1998, MICCAI.

[11]  Josien P. W. Pluim,et al.  Semi-automatic Reference Standard Construction for Quantitative Evaluation of Lung CT Registration , 2008, MICCAI.

[12]  G. Christensen,et al.  Intensity-and-Landmark-Driven , Inverse Consistent , B-Spline Registration and Analysis for Lung Imagery , 2009 .

[13]  Edwin J R van Beek,et al.  Effect of segmental bronchoalveolar lavage on quantitative computed tomography of the lung. , 2011, Academic radiology.

[14]  J. Ancochea,et al.  [Bronchoalveolar lavage]. , 1997, Archivos de bronconeumologia.

[15]  Gary E. Christensen,et al.  Tissue volume and vesselness measure preserving nonrigid registration of lung CT images , 2010, Medical Imaging.

[16]  J. Shelhamer,et al.  Abnormalities on ventilation/perfusion lung scans induced by bronchoalveolar lavage. , 1993, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[17]  E L Ritman,et al.  Effect of body orientation on regional lung expansion in dog and sloth. , 1985, Journal of applied physiology.

[18]  Joseph M. Reinhardt,et al.  Anatomy-Guided Lung Lobe Segmentation in X-Ray CT Images , 2009, IEEE Transactions on Medical Imaging.

[19]  J. Gurney,et al.  Bronchoalveolar lavage: radiographic manifestations. , 1987, Radiology.

[20]  Jiwoong Choi,et al.  Simulation of pulmonary air flow with a subject-specific boundary condition. , 2010, Journal of biomechanics.

[21]  C. J. Kotre,et al.  Anatomical distribution of bronchoalveolar lavage fluid as assessed by digital subtraction radiography. , 1987, Thorax.

[22]  Seungyong Lee,et al.  Injectivity Conditions of 2D and 3D Uniform Cubic B-Spline Functions , 2000, Graph. Model..