OCCUPATIONAL RADIATION EXPOSURE DOSE OF THE EYE IN DEPARTMENT OF CARDIAC ARRHYTHMIA PHYSICIAN.

Interventional radiology (IR) procedures tend to be complex, which delivers high radiation exposure to patient. In the present study, we measured the radiation exposure dose [Hp(3)] in the eye using a direct eye dosemeter placed next to the physician's eye during procedures. Physicians wore a direct eye dosemeter just lateral to eyes and an additional direct eye dosemeter outside the radiation protective eyeglasses close to their eyes. Additionally, a neck glass badge was worn at the neck. Although we found a positive correlation between the left neck glass badge dose [Hp(0.07)] and the left eye lens dose [Hp(3)], the value of R2 of the regression equation were 0.62 and 0.71 (outside and inside). We thought that the exact eye lens dose might not be estimated from the neck glass badge. In conclusion, a correct evaluation of the lens dose [Hp(3)] using the direct eye dosemeter is recommended for tachyarrhythmia physicians.

[1]  O. Ciraj-Bjelac,et al.  OCCUPATIONAL EYE LENS DOSE ESTIMATED USING WHOLE-BODY DOSEMETER IN INTERVENTIONAL CARDIOLOGY AND RADIOLOGY: A MONTE CARLO STUDY. , 2019, Radiation protection dosimetry.

[2]  H. Toyoshima,et al.  OCCUPATIONAL RADIATION EXPOSURE OF THE EYE IN NEUROVASCULAR INTERVENTIONAL PHYSICIAN. , 2019, Radiation protection dosimetry.

[3]  George E. Liu,et al.  Genome-wide analysis reveals differential selection involved with copy number variation in diverse Chinese Cattle , 2017, Scientific Reports.

[4]  K. Chida,et al.  Occupational eye dose in interventional cardiology procedures , 2017, Scientific Reports.

[5]  H. Toyoshima,et al.  Direct Dose Measurement On Patient During Percutaneous Coronary Intervention Procedures Using Radiophotoluminescence Glass Dosimeters , 2016, Radiation protection dosimetry.

[6]  J. Ryan,et al.  Occupational radiation dose to eyes from interventional radiology procedures in light of the new eye lens dose limit from the International Commission on Radiological Protection. , 2015, The British journal of radiology.

[7]  T. Moritake,et al.  Fundamental study on the characteristics of a radiophotoluminescence glass dosemeter with no energy compensation filter for measuring patient entrance doses in cardiac interventional procedures. , 2014, Radiation protection dosimetry.

[8]  J Farah,et al.  Efficiency of radiation protection equipment in interventional radiology: a systematic Monte Carlo study of eye lens and whole body doses , 2014, Journal of radiological protection : official journal of the Society for Radiological Protection.

[9]  Donald L. Miller,et al.  Patient skin reactions from interventional fluoroscopy procedures. , 2014, AJR. American journal of roentgenology.

[10]  C. Martin,et al.  Assessment of eye and body dose for interventional radiologists, cardiologists, and other interventional staff , 2013, Journal of radiological protection : official journal of the Society for Radiological Protection.

[11]  G. O'reilly,et al.  Occupational radiation dose to eyes from endoscopic retrograde cholangiopancreatography procedures in light of the revised eye lens dose limit from the International Commission on Radiological Protection. , 2013, The British journal of radiology.

[12]  Masayuki Zuguchi,et al.  Occupational dose in interventional radiology procedures. , 2013, AJR. American journal of roentgenology.

[13]  Koichi Chida,et al.  The necessity of follow-up for radiation skin injuries in patients after percutaneous coronary interventions: radiation skin injuries will often be overlooked clinically , 2012, Acta radiologica.

[14]  T. Sakae,et al.  Precise mapping system of entrance skin dose during endovascular embolization for cerebral aneurysm , 2011 .

[15]  K. Chida,et al.  Clarifying and visualizing sources of staff-received scattered radiation in interventional procedures. , 2011, AJR. American journal of roentgenology.

[16]  G. Gualdrini,et al.  Measurements of eye lens doses in interventional radiology and cardiology: Final results of the ORAMED project , 2011 .

[17]  Masayuki Zuguchi,et al.  Radiation dose to the pediatric cardiac catheterization and intervention patient. , 2010, AJR. American journal of roentgenology.

[18]  T. Ishibashi,et al.  Radiation dose and radiation protection for patients and physicians during interventional procedure. , 2010, Journal of radiation research.

[19]  Masayuki Zuguchi,et al.  Radiation dose of interventional radiology system using a flat-panel detector. , 2009, AJR. American journal of roentgenology.

[20]  Y. Matsumaru,et al.  Dose Measurement on Both Patients and Operators during Neurointerventional Procedures Using Photoluminescence Glass Dosimeters , 2008, American Journal of Neuroradiology.

[21]  Masayuki Zuguchi,et al.  Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. , 2006, AJR. American journal of roentgenology.

[22]  Masayuki Zuguchi,et al.  Does digital acquisition reduce patients' skin dose in cardiac interventional procedures? An experimental study. , 2004, AJR. American journal of roentgenology.

[23]  W. Huda,et al.  Radiation-induced temporary epilation after a neuroradiologically guided embolization procedure. , 1994, Radiology.

[24]  C. Clement,et al.  Radiological protection in cardiology , 2012 .

[25]  Koichi Chida,et al.  Evaluating the maximum patient radiation dose in cardiac interventional procedures. , 2011, Radiation protection dosimetry.

[26]  E P Efstathopoulos,et al.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures. , 2011, The British journal of radiology.

[27]  Virginia Tsapaki,et al.  Radiation exposure to patients during interventional procedures in 20 countries: initial IAEA project results. , 2009, AJR. American journal of roentgenology.

[28]  J. Valentin The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103. , 2007, Annals of the ICRP.

[29]  J. Valentin,et al.  Avoidance of radiation injuries from medical interventional procedures. , 2000, Annals of the ICRP.