Estimation of Cardiovascular Risk Predictors from Non-Invasively Measured Diametric Pulse Volume Waveforms via Multiple Measurement Information Fusion

This paper presents a novel multiple measurement information fusion approach to the estimation of cardiovascular risk predictors from non-invasive pulse volume waveforms measured at the body’s diametric (arm and ankle) locations. Leveraging the fact that diametric pulse volume waveforms originate from the common central pulse waveform, the approach estimates cardiovascular risk predictors in three steps by: (1) deriving lumped-parameter models of the central-diametric arterial lines from diametric pulse volume waveforms, (2) estimating central blood pressure waveform by analyzing the diametric pulse volume waveforms using the derived arterial line models, and (3) estimating cardiovascular risk predictors (including central systolic and pulse pressures, pulse pressure amplification, and pulse transit time) from the arterial line models and central blood pressure waveform in conjunction with the diametric pulse volume waveforms. Experimental results obtained from 164 human subjects with a wide blood pressure range (systolic 144 mmHg and diastolic 103 mmHg) showed that the approach could estimate cardiovascular risk predictors accurately (r ≥ 0.78). Further analysis showed that the approach outperformed a generalized transfer function regardless of the degree of pulse pressure amplification. The approach may be integrated with already available medical devices to enable convenient out-of-clinic cardiovascular risk prediction.

[1]  J. Hahn,et al.  Model-Based Blind System Identification Approach to Estimation of Central Aortic Blood Pressure Waveform From Noninvasive Diametric Circulatory Signals , 2017 .

[2]  E. Boerwinkle,et al.  Baseline predictors of central aortic blood pressure: a PEAR substudy. , 2014, Journal of the American Society of Hypertension : JASH.

[3]  C. Szmigielski,et al.  Automated oscillometric measurement of the ankle–brachial index in patients with coronary artery disease , 2013, Hypertension Research.

[4]  M. O'Rourke,et al.  Transfer function-derived central pressure and cardiovascular disease events: the Framingham Heart Study. , 2016, Journal of hypertension.

[5]  S. Chuang,et al.  Brachial-ankle vs carotid-femoral pulse wave velocity as a determinant of cardiovascular structure and function , 2008, Journal of Human Hypertension.

[6]  Jin-Oh Hahn,et al.  Estimation of pulse transit time using two diametric blood pressure waveform measurements. , 2010, Medical engineering & physics.

[7]  Hao-Min Cheng,et al.  Central or peripheral systolic or pulse pressure: which best relates to target organs and future mortality? , 2009, Journal of hypertension.

[8]  Shaohua Wang,et al.  Subject-specific estimation of central aortic blood pressure via system identification: preliminary in-human experimental study , 2014, Medical & Biological Engineering & Computing.

[9]  I. Wilkinson,et al.  Evaluation of the Vicorder, a novel cuff-based device for the noninvasive estimation of central blood pressure , 2013, Journal of hypertension.

[10]  Tamar Frankel [The theory and the practice...]. , 2001, Tijdschrift voor diergeneeskunde.

[11]  J. Cockcroft,et al.  Central blood pressure: current evidence and clinical importance. , 2014, European heart journal.

[12]  Ramakrishna Mukkamala,et al.  Investigation of Viscoelasticity in the Relationship Between Carotid Artery Blood Pressure and Distal Pulse Volume Waveforms , 2018, IEEE Journal of Biomedical and Health Informatics.

[13]  Wen-Chung Yu,et al.  Measurement accuracy of a stand-alone oscillometric central blood pressure monitor: a validation report for Microlife WatchBP Office Central. , 2013, American journal of hypertension.

[14]  H. Harry Asada,et al.  Blind Identification of Two-Channel IIR Systems With Application to Central Cardiovascular Monitoring , 2009 .

[15]  C-H Chen,et al.  Comparison of two generalized transfer functions for measuring central systolic blood pressure by an oscillometric blood pressure monitor , 2013, Journal of Human Hypertension.

[16]  D Agnoletti,et al.  Comparative study of methodologies for pulse wave velocity estimation , 2008, Journal of Human Hypertension.

[17]  M. Karamanoglu,et al.  An analysis of the relationship between central aortic and peripheral upper limb pressure waves in man. , 1993, European heart journal.

[18]  Riccardo Pini,et al.  Central but not brachial blood pressure predicts cardiovascular events in an unselected geriatric population: the ICARe Dicomano Study. , 2008, Journal of the American College of Cardiology.

[19]  H. Harry Asada,et al.  Modeling and 2-sensor blind identification of human cardiovascular system , 2009 .

[20]  G. Mancia,et al.  Central blood pressure measurements and antihypertensive therapy: a consensus document. , 2007, Hypertension.

[21]  Marie Gerhard-Herman,et al.  Automated Oscillometric Determination of the Ankle–Brachial Index Provides Accuracy Necessary for Office Practice , 2006, Hypertension.

[22]  Siegfried Wassertheurer,et al.  Accuracy of commercial devices and methods for noninvasive estimation of aortic systolic blood pressure a systematic review and meta-analysis of invasive validation studies , 2016, Journal of hypertension.

[23]  Piotr Jankowski,et al.  Central blood pressure and hypertension: role in cardiovascular risk assessment. , 2009, Clinical science.

[24]  D. Levy,et al.  Relations of Central Hemodynamics and Aortic Stiffness with Left Ventricular Structure and Function: The Framingham Heart Study , 2016, Journal of the American Heart Association.

[25]  M Maarten Steinbuch,et al.  Periodic Signal Tracking for Lightly Damped Systems , 2017 .

[26]  C H Chen,et al.  Validation of carotid artery tonometry as a means of estimating augmentation index of ascending aortic pressure. , 1996, Hypertension.

[27]  D. Levy,et al.  Changes in Arterial Stiffness and Wave Reflection With Advancing Age in Healthy Men and Women: The Framingham Heart Study , 2004, Hypertension.

[28]  Wen-Chung Yu,et al.  Measurement of central aortic pulse pressure: noninvasive brachial cuff-based estimation by a transfer function vs. a novel pulse wave analysis method. , 2012, American journal of hypertension.

[29]  Hao-Min Cheng,et al.  Estimation of central systolic blood pressure using an oscillometric blood pressure monitor , 2010, Hypertension Research.

[30]  N. Stergiopulos,et al.  Arterial pressure transfer characteristics: effects of travel time. , 2007, American journal of physiology. Heart and circulatory physiology.

[31]  Kozo Hirata,et al.  Pulse wave analysis and pulse wave velocity: a review of blood pressure interpretation 100 years after Korotkov. , 2006, Circulation journal : official journal of the Japanese Circulation Society.

[32]  Hao-min Cheng,et al.  Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central , 2016, Pulse.

[33]  Qi Zhang,et al.  Validation of the noninvasive assessment of central blood pressure by the SphygmoCor and Omron devices against the invasive catheter measurement. , 2011, American journal of hypertension.

[34]  Mark D. Huffman,et al.  Heart Disease and Stroke Statistics—2016 Update: A Report From the American Heart Association , 2016, Circulation.

[35]  H. Struijker‐Boudier,et al.  Expert consensus document on arterial stiffness: methodological issues and clinical applications. , 2006, European heart journal.

[36]  A. Schutte,et al.  Comparison of central pressure estimates obtained from SphygmoCor, Omron HEM-9000AI and carotid applanation tonometry , 2011, Journal of hypertension.

[37]  R. Mukkamala,et al.  Blind identification of the aortic pressure waveform from multiple peripheral artery pressure waveforms. , 2007, American journal of physiology. Heart and circulatory physiology.

[38]  Consensus Document , 2005 .

[39]  P. Palatini,et al.  Accuracy of Microlife WatchBP Office ABI monitor assessed according to the 2002 European Society of Hypertension protocol and the British Hypertension Society protocol , 2011, Blood pressure monitoring.

[40]  Michael F O'Rourke,et al.  Validation of the transfer function technique for generating central from peripheral upper limb pressure waveform. , 2004, American journal of hypertension.

[41]  D. Kass,et al.  Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry , 1999, IEEE Transactions on Biomedical Engineering.

[42]  Yoav Ben-Shlomo,et al.  Aortic pulse wave velocity improves cardiovascular event prediction: an individual participant meta-analysis of prospective observational data from 17,635 subjects. , 2014, Journal of the American College of Cardiology.

[43]  Survi Kyal,et al.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice , 2015, IEEE Transactions on Biomedical Engineering.

[44]  Daniel Levy,et al.  Aortic stiffness, blood pressure progression, and incident hypertension. , 2012, JAMA.

[45]  P. Boutouyrie,et al.  Measurement of Aortic Pulse Wave Velocity With a Connected Bathroom Scale , 2017, American journal of hypertension.

[46]  Thomas H Marwick,et al.  Validation of a Generalized Transfer Function to Noninvasively Derive Central Blood Pressure During Exercise , 2006, Hypertension.

[47]  Nima Fazeli,et al.  Quantification of Wave Reflection Using Peripheral Blood Pressure Waveforms , 2015, IEEE Journal of Biomedical and Health Informatics.