Gait cycle comparions of cruciate sacrifice for total knee design.-explicit finite element
暂无分享,去创建一个
Kyoung Tak Kang | Joon Hee Park | Kwang Il Lee | Young Bock Shim | Ju Woong Jang | Heoung Jae Chun | Kwang-il Lee | H. Chun | Ju-woong Jang | K. Kang | Y. Shim | Joon-Hee Park
[1] Mark Taylor,et al. Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading. , 2007, Journal of biomechanics.
[2] M Beaugonin,et al. Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. , 2002, Journal of biomechanics.
[3] J L Lanovaz,et al. Dynamic simulation of a displacement-controlled total knee replacement wear tester , 2008, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[4] Yoon Hyuk Kim,et al. A laboratory-level surgical robot system for minimal invasive surgery (MIS) total knee arthroplasty , 2011 .
[5] Jason P. Halloran,et al. Explicit finite element modeling of total knee replacement mechanics. , 2005, Journal of biomechanics.
[6] R B Bourne,et al. Tibial Post Wear in Posterior Stabilized Total Knee Arthroplasty: An Unrecognized Source of Polyethylene Debris , 2001, The Journal of bone and joint surgery. American volume.
[7] D. Bartel,et al. Stresses in polyethylene components of contemporary total knee replacements. , 1995, Clinical orthopaedics and related research.
[8] John J. Callaghan,et al. Current Concepts Review - Wear in Total Hip and Knee Replacements* , 1999 .
[9] D. Bartel,et al. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. , 1986, The Journal of bone and joint surgery. American volume.
[10] J J Callaghan,et al. Wear in total hip and knee replacements. , 2000, The Journal of bone and joint surgery. American volume.
[11] N. P. Thomas,et al. Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement. , 2005, The Journal of bone and joint surgery. British volume.
[12] E. A. Reeves,et al. Comparison of gas plasma and gamma irradiation in air sterilization on the delamination wear of the ultra-high molecular weight polyethylene used in knee replacements , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.
[13] D L Bartel,et al. Residual stresses in ultra‐high molecular weight polyethylene loaded cyclically by a rigid moving indenter in nonconforming geometries , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[14] B. Haas. Tibial post impingement in posterior-stabilized total knee arthroplasty. , 2006, Orthopedics.
[15] D R Broome,et al. A knee simulating machine for performance evaluation of total knee replacements. , 1997, Journal of biomechanics.
[16] D. Bartel,et al. Postirradiation Aging Affects Stress and Strain in Polyethylene Components , 1998, Clinical orthopaedics and related research.
[17] C. Ranawat,et al. Total Condylar Knee Replacement: A 20-Year Followup Study , 2001, Clinical orthopaedics and related research.
[18] P S Walker,et al. The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements. , 2001, Journal of biomedical materials research.
[19] T. Thornhill,et al. Total knee arthroplasty with the PFC system. Results at a minimum of ten years and survivorship analysis. , 1998, The Journal of bone and joint surgery. British volume.
[20] Jason P. Halloran,et al. Comparison of deformable and elastic foundation finite element simulations for predicting knee replacement mechanics. , 2005, Journal of biomechanical engineering.
[21] C. Jewett,et al. The yielding, plastic flow, and fracture behavior of ultra-high molecular weight polyethylene used in total joint replacements. , 1998, Biomaterials.
[22] P. Walker,et al. Computer model to predict subsurface damage in tibial inserts of total knees , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[23] A H Burstein,et al. Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. , 1983, Journal of biomedical materials research.
[24] Yoon-Hyuk Kim,et al. In vivo kinematics of a cruciate retaining mobile-bearing total knee arthroplasty , 2011 .
[25] J. D'arcy,et al. Fracture of the polyethylene tibial post in posterior stabilized (Insall Burstein II) total knee arthroplasty. , 2000, The Journal of arthroplasty.
[26] V. Goldberg,et al. Effect of Resin Type and Manufacturing Method on Wear of Polyethylene Tibial Components , 2000, Clinical orthopaedics and related research.
[27] S. M. Kurt,et al. Miniature specimen shear punch test for UHMWPE used in total joint replacements. , 2002, Biomaterials.
[28] H Miura,et al. Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty. , 2005, The Journal of bone and joint surgery. British volume.
[29] T. Brown,et al. Gait Cycle Finite Element Comparison of Rotating-Platform Total Knee Designs , 2003, Clinical orthopaedics and related research.