Gait cycle comparions of cruciate sacrifice for total knee design.-explicit finite element

Joint kinematics and contact mechanics dictate the success of current total knee replacement (TKR) devices. Computational contact prediction is a feasible way of evaluating new TKR designs prior to physical testing and implementation. Previous finite element (FE) knee models have generally been used to predict stresses on contact areas and/or areas subjected to static or quasi-static loading. Explicit dynamic FE analyses have recently been used to effectively predict TKR kinematics and contact mechanics during dynamic loading conditions. In this study, we compared the functional load transmission and kinematic performance of two posterior-stabilized designs, standard and post-cam TKR versions, over a standardized loading cycle using three-dimensional contact finite element analysis. Our objective was to develop and experimentally validate an explicit FE TKR model that incorporates femoral-bearing articulations. Finite element-based computational contact pressure predictions were applied to gait cycles using both force-controlled and displacement-controlled inputs. A standard prosthesis showed a reduction in contact pressure compared with post-cam prosthesis components, as it redistributed the knee motion to two articulating interfaces with more linear motions at each interface. In this FE analysis, the wear of TKR bearings was dependent on kinematics at the articulating surfaces and on prosthesis design.

[1]  Mark Taylor,et al.  Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading. , 2007, Journal of biomechanics.

[2]  M Beaugonin,et al.  Simulation of a knee joint replacement during a gait cycle using explicit finite element analysis. , 2002, Journal of biomechanics.

[3]  J L Lanovaz,et al.  Dynamic simulation of a displacement-controlled total knee replacement wear tester , 2008, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[4]  Yoon Hyuk Kim,et al.  A laboratory-level surgical robot system for minimal invasive surgery (MIS) total knee arthroplasty , 2011 .

[5]  Jason P. Halloran,et al.  Explicit finite element modeling of total knee replacement mechanics. , 2005, Journal of biomechanics.

[6]  R B Bourne,et al.  Tibial Post Wear in Posterior Stabilized Total Knee Arthroplasty: An Unrecognized Source of Polyethylene Debris , 2001, The Journal of bone and joint surgery. American volume.

[7]  D. Bartel,et al.  Stresses in polyethylene components of contemporary total knee replacements. , 1995, Clinical orthopaedics and related research.

[8]  John J. Callaghan,et al.  Current Concepts Review - Wear in Total Hip and Knee Replacements* , 1999 .

[9]  D. Bartel,et al.  The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. , 1986, The Journal of bone and joint surgery. American volume.

[10]  J J Callaghan,et al.  Wear in total hip and knee replacements. , 2000, The Journal of bone and joint surgery. American volume.

[11]  N. P. Thomas,et al.  Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement. , 2005, The Journal of bone and joint surgery. British volume.

[12]  E. A. Reeves,et al.  Comparison of gas plasma and gamma irradiation in air sterilization on the delamination wear of the ultra-high molecular weight polyethylene used in knee replacements , 2000, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[13]  D L Bartel,et al.  Residual stresses in ultra‐high molecular weight polyethylene loaded cyclically by a rigid moving indenter in nonconforming geometries , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[14]  B. Haas Tibial post impingement in posterior-stabilized total knee arthroplasty. , 2006, Orthopedics.

[15]  D R Broome,et al.  A knee simulating machine for performance evaluation of total knee replacements. , 1997, Journal of biomechanics.

[16]  D. Bartel,et al.  Postirradiation Aging Affects Stress and Strain in Polyethylene Components , 1998, Clinical orthopaedics and related research.

[17]  C. Ranawat,et al.  Total Condylar Knee Replacement: A 20-Year Followup Study , 2001, Clinical orthopaedics and related research.

[18]  P S Walker,et al.  The effect of contact area on wear in relation to fixed bearing and mobile bearing knee replacements. , 2001, Journal of biomedical materials research.

[19]  T. Thornhill,et al.  Total knee arthroplasty with the PFC system. Results at a minimum of ten years and survivorship analysis. , 1998, The Journal of bone and joint surgery. British volume.

[20]  Jason P. Halloran,et al.  Comparison of deformable and elastic foundation finite element simulations for predicting knee replacement mechanics. , 2005, Journal of biomechanical engineering.

[21]  C. Jewett,et al.  The yielding, plastic flow, and fracture behavior of ultra-high molecular weight polyethylene used in total joint replacements. , 1998, Biomaterials.

[22]  P. Walker,et al.  Computer model to predict subsurface damage in tibial inserts of total knees , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  A H Burstein,et al.  Retrieval analysis of total knee prostheses: a method and its application to 48 total condylar prostheses. , 1983, Journal of biomedical materials research.

[24]  Yoon-Hyuk Kim,et al.  In vivo kinematics of a cruciate retaining mobile-bearing total knee arthroplasty , 2011 .

[25]  J. D'arcy,et al.  Fracture of the polyethylene tibial post in posterior stabilized (Insall Burstein II) total knee arthroplasty. , 2000, The Journal of arthroplasty.

[26]  V. Goldberg,et al.  Effect of Resin Type and Manufacturing Method on Wear of Polyethylene Tibial Components , 2000, Clinical orthopaedics and related research.

[27]  S. M. Kurt,et al.  Miniature specimen shear punch test for UHMWPE used in total joint replacements. , 2002, Biomaterials.

[28]  H Miura,et al.  Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty. , 2005, The Journal of bone and joint surgery. British volume.

[29]  T. Brown,et al.  Gait Cycle Finite Element Comparison of Rotating-Platform Total Knee Designs , 2003, Clinical orthopaedics and related research.