Micro-gas analysis system μGAS comprising a microchannel scrubber and a micro-fluorescence detector for measurement of hydrogen sulfide

Abstract A micro-gas analysis system, μGAS, is proposed here for the continuous and highly sensitive on-site measurement of atmospheric trace gases. The μGAS presented here is comprised of a microchannel scrubber and a high-sensitivity small fluorescence detector. The key to the μGAS is the fabrication of a good gas permeable membrane on a shallow channel to allow for the efficient accumulation of the analyte into the absorbing solution. The channel is formed by micromachining, and a gas permeable membrane of any desired thickness is formed by spin-coating on a fluorosilane-treated substrate. In this work, polydimethylsiloxane was used for both the channel block and the gas permeable membrane, and were easily tightly bonded. The microchannel structure ensures a high sensitivity, and the sensitivity is inversely proportional to the membrane thickness. The device, including the air supply function, is set in only 30-mm-cube. The performance of the μGAS has been demonstrated as a H 2 S gas sensor. The μGAS consumes only 1 ml of the reagent solution in 8 h of operation with a detection limit of 1 ppbv.

[1]  D. J. Harrison,et al.  Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip , 1993, Science.

[2]  T Kitamori,et al.  Integration of an immunosorbent assay system: analysis of secretory human immunoglobulin A on polystyrene beads in a microchip. , 2000, Analytical chemistry.

[3]  J. Johansson,et al.  Real-Time Imaging through Optical Fiber Array-Assisted Laser-Induced Fluorescence of Capillary Electrophoretic Enantiomer Separations. , 1999, Analytical chemistry.

[4]  Takehiko Kitamori,et al.  Three-layer flow membrane system on a microchip for investigation of molecular transport. , 2002, Analytical chemistry.

[5]  D. J. Harrison,et al.  Capillary electrophoresis and sample injection systems integrated on a planar glass chip , 1992 .

[6]  M. Rezac,et al.  Properties of rubbery polymers for the recovery of hydrogen sulfide from gasification gases , 2002 .

[7]  A. Cardoso,et al.  Analytical chemistry in a liquid film/droplet , 1995 .

[8]  P K Dasgupta,et al.  Renewable liquid film-based electrochemical sensor for gaseous hydroperoxides. , 1997, Talanta.

[9]  Air-cooled cold trap channel integrated in a microfluidic device for monitoring airborne BTEX with an improved detection limit. , 2002, Analytical chemistry.

[10]  M. Esashi,et al.  Vacuum packaging for microsensors by glass-silicon anodic bonding , 1994 .

[11]  C H Mastrangelo,et al.  Monolithic capillary electrophoresis device with integrated fluorescence detector. , 2001, Analytical chemistry.

[12]  George M. Whitesides,et al.  Reconfigurable diffraction gratings based on elastomeric microfluidic devices , 1999 .

[13]  T. Korenaga,et al.  Analytical Chemistry for Environmental and Human Health. Development of a gas absorption microchip using porous glass and its evaluation for analytical applications. , 2000 .

[14]  Y. Hamada,et al.  Development of an automated, simultaneous and continuous measurement system by using a diffusion scrubber coupled to ion chromatography for monitoring trace acidic and basic gases (HCl, HNO3, SO2 and NH3) in the atmosphere , 1999 .

[15]  Purnendu K. Dasgupta,et al.  A Renewable Liquid Droplet as a Sampler and a Windowless Optical Cell. Automated Sensor for Gaseous Chlorine , 1995 .

[16]  Phillip W. Barth,et al.  Silicon fusion bonding for fabrication of sensors, actuators and microstructures , 1990 .

[17]  Y. Komazaki,et al.  Development of an automated measurement system using a diffusion scrubber and high-performance liquid chromatography for the monitoring of formaldehyde and acetaldehyde in automotive exhaust gas. , 1998, The Analyst.

[18]  Dasgupta,et al.  Measurement of atmospheric hydrogen peroxide and hydroxymethyl hydroperoxide with a diffusion scrubber and light emitting diode-liquid core waveguide-based fluorometry , 2000, Analytical chemistry.

[19]  Takehiko Kitamori,et al.  Chemicofunctional membrane for integrated chemical processes on a microchip. , 2003, Analytical chemistry.

[20]  W. Jaeschke,et al.  A continuous flow instrument with flow regulation and automatic sensitivity range adaptation for the determination of atmospheric H2S , 1995 .

[21]  O. Niwa,et al.  Microfluidic device for airborne BTEX detection. , 2001, Analytical chemistry.

[22]  M. Hutterli,et al.  Measurement of atmospheric formaldehyde with a diffusion scrubber and light‐emitting diode–liquid‐core waveguide based fluorometry , 2001 .

[23]  A. Cǎpriţǎ,et al.  Continuous permeation of analytes through a thin poly(dimethylsiloxane) membrane followed by sorbent trapping for their gas chromatographic monitoring. , 2002, Journal of chromatography. A.

[24]  Analysis of permeation transients of pure gases through dense polymeric membranes measured by a new permeation apparatus , 2000 .

[25]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[26]  K. Toda Trends in Atmospheric Trace Gas Measurement Instruments with Membrane-based Gas Diffusion Scrubbers , 2004, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[27]  J. Ingle,et al.  The SLIM spectrometer. , 2003, Analytical chemistry.

[28]  J. Lodge,et al.  Sensitive method for measurement of atmospheric hydrogen sulfide. , 1972, Analytical chemistry.

[29]  Dasgupta,et al.  A continuous film-recirculable drop gas-liquid equilibration device. Measurement of trace gaseous ammonia , 2000, Analytical chemistry.

[30]  Y Komazaki,et al.  Automated measurement system for H2O2 in the atmosphere by diffusion scrubber sampling and HPLC analysis of Ti(IV)-PAR-H2O2 complex. , 2001, The Analyst.

[31]  K. Toda,et al.  Field instrument for simultaneous large dynamic range measurement of atmospheric hydrogen sulfide, methanethiol, and sulfur dioxide. , 2004, Environmental Science and Technology.

[32]  A. Cardoso,et al.  Fluorometric fiber optic drop sensor for atmospheric hydrogen sulfide. , 1997, Talanta.

[33]  F. Stewart,et al.  Gas transport characteristics of plasma treated poly(dimethylsiloxane) and polyphosphazene membrane materials , 2002 .

[34]  May-Britt Hägg,et al.  Membrane purification of Cl2 gas: I. Permeabilities as a function of temperature for Cl2, O2, N2, H2 in two types of PDMS membranes , 2000 .

[35]  T. Fujii,et al.  Handling of Picoliter Liquid Samples in a Poly(dimethylsiloxane)-Based Microfluidic Device , 1999 .

[36]  T Kitamori,et al.  Determination of carcinoembryonic antigen in human sera by integrated bead-bed immunoassay in a microchip for cancer diagnosis. , 2001, Analytical chemistry.

[37]  Takehiko Kitamori,et al.  On-Chip Integration of Neutral Ionophore-Based Ion Pair Extraction Reaction , 2001 .

[38]  Nghia Chiem,et al.  Micromachinng chemical and biochemical analysis and reaction systems on glass substrates , 1996 .

[39]  Fluorescent derivatization of nitrite ions with 2,3-diaminonaphthalene utilizing a pH gradient in a Y-shaped microchannel. , 2001, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[40]  Gregor Ocvirk,et al.  Integrated microfluidic electrophoresis system for analysis of genetic materials using signal amplification methods. , 2002, Analytical chemistry.

[41]  K. Toda,et al.  A wall-jet ring disk electrode fabricated within a thin-layered micromachined cell , 1999 .

[42]  J. M. Lee,et al.  Study of transport of pure and mixed CO2/N2 gases through polymeric membranes , 2000 .

[43]  K. Toda,et al.  Fluorometric field instrument for continuous measurement of atmospheric hydrogen sulfide. , 2001, Analytical Chemistry.

[44]  A D Stroock,et al.  An integrated fluorescence detection system in poly(dimethylsiloxane) for microfluidic applications. , 2001, Analytical chemistry.

[45]  K. Toda,et al.  Hybrid microfabricated device for field measurement of atmospheric sulfur dioxide. , 2002, Analytical chemistry.

[46]  M. Morris,et al.  Plastic microchip electrophoresis with analyte velocity modulation. Application to fluorescence background rejection. , 2000, Analytical chemistry.

[47]  A. Helmicki,et al.  An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities. , 2002, Lab on a chip.

[48]  Takehiko Kitamori,et al.  Single-cell analysis by a scanning thermal lens microscope with a microchip: direct monitoring of cytochrome c distribution during apoptosis process. , 2002, Analytical chemistry.

[49]  D. J. Harrison,et al.  Microchip-based capillary electrophoresis for immunoassays: analysis of monoclonal antibodies and theophylline. , 1997, Analytical chemistry.

[50]  Stephen C. Jacobson,et al.  Low temperature bonding for microfabrication of chemical analysis devices , 1997 .

[51]  I. Sanemasa,et al.  Amperometric gas detection using a micro-ring electrode coupled with a gas-absorbing droplet , 2000 .

[52]  J. Lodge,et al.  Fluorescence determinatioof sub-parts per billion hydrogen sulfide in the atmosphere. , 1969, Analytical Chemistry.

[53]  Nghia Chiem,et al.  Room temperature bonding of micromachined glass devices for capillary electrophoresis , 2000 .

[54]  Takehiko Kitamori,et al.  Nanochannels on a Fused-Silica Microchip and Liquid Properties Investigation by Time-Resolved Fluorescence Measurements , 2002 .