Endovascular abdominal aortic aneurysm repair: nonenhanced volumetric CT for follow-up.

PURPOSE To evaluate the clinical usefulness of volumetric analysis at nonenhanced computed tomography (CT) as the sole method with which to follow up endovascular abdominal aortic aneurysm repair (EVAR) and to identify endoleaks causing more than 2% volumetric increase from the previous volume determination. MATERIALS AND METHODS The study had institutional review board approval. Images were reviewed retrospectively in a HIPAA-compliant manner for 230 CT studies in 70 patients (11 women, 59 men; mean age, 74 years) who underwent EVAR. The scannning protocol consisted of three steps: (a) contrast material-enhanced CT angiography before endovascular stent placement, (b) contrast-enhanced CT angiography 0-3 months after repair to depict immediate complications, and (c) nonenhanced CT at 3, 6, and 12 months after repair. At each follow-up visit, immediate aortic volume analysis was performed. If the interval volumetric change was 2% or less, no further imaging was performed. If the volume increased by more than 2% on the nonenhanced CT image, contrast-enhanced CT angiography was performed immediately to identify the suspected endoleak. Confidence intervals (CIs) were obtained by using bootstrapping to account for repeated measurements in the same patients. RESULTS Mean volume decrease was -3.2% (95% CI: -4.7%, -1.9%) in intervals without occurrence of a clinically relevant endoleak (n = 183). Types I and III high-pressure endoleaks (n = 10) showed a 10.0% (95% CI: 5.0%, 18.2%) interval volumetric increase. Type II low-pressure endoleaks (n = 37) showed a 5.4% (95% CI: 4.6%, 6.2%) interval volumetric increase. Endoleaks associated with minimal aortic volume increase of less than 2% did not require any intervention. This protocol reduced radiation exposure by approximately 57%-82% in an average-sized patient. CONCLUSION Serial volumetric analysis of aortic aneurysm with nonenhanced CT serves as an adequate screening test for endoleak, causing volumetric increase of more than 2% from the volume seen at the previous examination.

[1]  Borut Marincek,et al.  Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. , 2008, Radiology.

[2]  T. Pilgram,et al.  Clinical significance of endoleak detected on follow-up CT after endovascular repair of abdominal aortic aneurysm. , 2008, AJR. American journal of roentgenology.

[3]  R. Greenberg,et al.  From the Southern Association for Vascular Surgery Redefining postoperative surveillance after endovascular aneurysm repair : Recommendations based on 5-year follow-up in the US Zenith multicenter trial , 2008 .

[4]  V. Lee,et al.  Nonenhanced MR angiography. , 2008, Radiology.

[5]  J Paul Finn,et al.  Noncontrast 3D Steady-State Free-Precession Magnetic Resonance Angiography of the Whole Chest Using Nonselective Radiofrequency Excitation over a Large Field of View: Comparison With Single-Phase 3D Contrast-Enhanced Magnetic Resonance Angiography , 2008, Investigative radiology.

[6]  P. Weale,et al.  Unenhanced MR angiography of the thoracic aorta: initial clinical evaluation. , 2008, AJR. American journal of roentgenology.

[7]  A. Cotroneo,et al.  Endovascular treatment of thoracic aortic diseases: Follow-up and complications with multi-detector computed tomography angiography. , 2008, European journal of radiology.

[8]  S. Walsh,et al.  Renal Consequences of Endovascular Abdominal Aortic Aneurysm Repair , 2008, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[9]  R. Lookstein,et al.  Endovascular stent-graft repair of failed endovascular abdominal aortic aneurysm repair. , 2008, Annals of vascular surgery.

[10]  Diego R. Martín,et al.  Response to the FDA's May 23, 2007, nephrogenic systemic fibrosis update. , 2008, Radiology.

[11]  M. Gawenda,et al.  Renal response to open and endovascular repair of abdominal aortic aneurysm: a prospective study. , 2008, Annals of vascular surgery.

[12]  J. Golzarian,et al.  Multidetector CT in abdominal aortic aneurysm following endovascular repair: how to consider the value of a delayed phase. , 2007, Radiology.

[13]  A. Djamali,et al.  Nephrogenic systemic fibrosis: risk factors and incidence estimation. , 2007, Radiology.

[14]  Koen L. Vincken,et al.  Use of Dynamic Computed Tomography to Evaluate Pre- and Postoperative Aortic Changes in AAA Patients Undergoing Endovascular Aneurysm Repair , 2007, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[15]  D. Raithel,et al.  Seven years' single center experience of Powerlink unibody bifurcated endograft for endovascular aortic aneurysm repair. , 2007, The Journal of cardiovascular surgery.

[16]  M. Macari,et al.  Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose? , 2006, Radiology.

[17]  L. Bonomo,et al.  Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection? , 2006, Radiology.

[18]  F. Veith,et al.  Type II endoleak after endoaortic graft implantation: diagnosis with helical CT arteriography. , 2006, Radiology.

[19]  M. Watkins,et al.  Long-term Outcomes After Endovascular Abdominal Aortic Aneurysm Repair: The First Decade , 2006, Annals of surgery.

[20]  N. Osada,et al.  Long-term outcome after Talent endograft implantation for aneurysms of the abdominal aorta: a multicenter retrospective study. , 2006, Journal of vascular surgery.

[21]  Claudio Vignali,et al.  Endovascular Repair of Abdominal Aortic Aneurysms: Analysis of Aneurysm Volumetric Changes at Mid-Term Follow-Up , 2005, CardioVascular and Interventional Radiology.

[22]  J. Fine,et al.  Aortic aneurysm volume calculation: effect of operator experience , 2005, Abdominal Imaging.

[23]  C. Zarins,et al.  What is the significance of endoleaks and endotension. , 2004, The Surgical clinics of North America.

[24]  Matthew A. Corriere,et al.  Endoleak Following Endovascular Abdominal Aortic Aneurysm Repair: Implications for Duration of Screening , 2004, Annals of surgery.

[25]  Late-onset Type II Endoleaks and the Incidence of Secondary Intervention , 2004, Annals of vascular surgery.

[26]  Rodney A. White,et al.  Volume regression of abdominal aortic aneurysms and its relation to successful endoluminal exclusion. , 2003, Journal of vascular surgery.

[27]  S. Stavropoulos,et al.  Endoleaks after endovascular repair of abdominal aortic aneurysms. , 2003, Journal of vascular and interventional radiology : JVIR.

[28]  E. Verhoeven,et al.  Decision-making in follow-up after endovascular aneurysm repair based on diameter and volume measurements: a blinded comparison. , 2003, European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery.

[29]  F. Veith,et al.  Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisitions. , 2003, Radiology.

[30]  L. Norgren,et al.  Significance of endoleaks after endovascular repair of abdominal aortic aneurysms: The EUROSTAR experience. , 2002, Journal of vascular surgery.

[31]  C. Rockman,et al.  Are Type II (Branch Vessel) Endoleaks Really Benign? , 2002, Annals of vascular surgery.

[32]  M. Schocke,et al.  Serial CT Volume Measurements after Endovascular Aortic Aneurysm Repair , 2001, Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists.

[33]  M. Matsuzaki,et al.  Complications of endovascular repair for thoracic and abdominal aortic aneurysm: an imaging spectrum. , 2000, Radiographics : a review publication of the Radiological Society of North America, Inc.

[34]  T. Riles,et al.  The significance and management of the leaking endograft. , 1999, Seminars in vascular surgery.

[35]  James May,et al.  Type III and Type IV Endoleak: Toward a Complete Definition of Blood Flow in the Sac after Endoluminal AAA Repair , 1998, Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery.

[36]  P. Gevenois,et al.  Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition. , 1998, AJR. American journal of roentgenology.

[37]  G. White,et al.  Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. , 1997 .

[38]  R. Allen,et al.  Delayed rupture of aortic aneurysms following endovascular stent grafting. , 1995, American journal of surgery.