The SCoRE residual: a quality index to assess the accuracy of joint estimations.

The determination of an accurate centre of rotation (CoR) from skin markers is essential for the assessment of abnormal gait patterns in clinical gait analysis. Despite the many functional approaches to estimate CoRs, no non-invasive analytical determination of the error in the reconstructed joint location is currently available. The purpose of this study was therefore to verify the residual of the symmetrical centre of rotation estimation (SCoRE) as a reliable indirect measure of the error of the computed joint centre. To evaluate the SCoRE residual, numerical simulations were performed to evaluate CoR estimations at different ranges of joint motion. A statistical model was developed and used to determine the theoretical relationships among the SCoRE residual, the magnitude of the skin marker artefact, the corrections to the marker positions, and the error of the CoR estimations to the known centre of rotation. We found that the equation err=0.5r(s) provides a reliable relationship among the CoR error, err, and the scaled SCoRE residual, r(s), providing that any skin marker artefact is first minimised using the optimal common shape technique (OCST). Measurements on six healthy volunteers showed a reduction of SCoRE residual from 11 to below 6mm and therefore demonstrated consistency of the theoretical considerations and numerical simulations with the in vivo data. This study also demonstrates the significant benefit of the OCST for reducing skin marker artefact and thus for predicting the accuracy of determining joint centre positions in functional gait analysis. For the first time, this understanding of the SCoRE residual allows a measure of error in the non-invasive assessment of joint centres. This measure now enables a rapid assessment of the accuracy of the CoR as well as an estimation of the reproducibility and repeatability of skeletal motion patterns.

[1]  Patrick Lacouture,et al.  Comparison of the SCoRE and HA methods for locating in vivo the glenohumeral joint centre. , 2007, Journal of biomechanics.

[2]  Bruce A MacWilliams,et al.  A comparison of four functional methods to determine centers and axes of rotations. , 2008, Gait & posture.

[3]  Kjartan Halvorsen,et al.  Bias compensated least squares estimate of the center of rotation. , 2003, Journal of biomechanics.

[4]  Angelo Cappello,et al.  Quantification of soft tissue artefact in motion analysis by combining 3D fluoroscopy and stereophotogrammetry: a study on two subjects. , 2005, Clinical biomechanics.

[5]  H. Röhrle,et al.  Gait characteristics and muscle and joint forces in children with cerebral palsy , 1987 .

[6]  G. Bergmann,et al.  Musculo-skeletal loading conditions at the hip during walking and stair climbing. , 2001, Journal of biomechanics.

[7]  A. Cappozzo Considerations on clinical gait evaluation. , 1983, Journal of biomechanics.

[8]  K. Mardia,et al.  Statistical Shape Analysis , 1998 .

[9]  Aurelio Cappozzo,et al.  Hip joint centre location: an ex vivo study. , 2009, Journal of biomechanics.

[10]  Aurelio Cappozzo,et al.  Gait analysis methodology , 1984 .

[11]  Hanna Schell,et al.  On the influence of soft tissue coverage in the determination of bone kinematics using skin markers , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[12]  T P Andriacchi,et al.  A point cluster method for in vivo motion analysis: applied to a study of knee kinematics. , 1998, Journal of biomechanical engineering.

[13]  T.-W. Lu,et al.  A three-dimensional computer graphics-based animated model of the human locomotor system with anatomical joint constraints , 1998 .

[14]  Oliver Rettig,et al.  A new kinematic model of the upper extremity based on functional joint parameter determination for shoulder and elbow. , 2009, Gait & posture.

[15]  I Söderkvist,et al.  Determining the movements of the skeleton using well-configured markers. , 1993, Journal of biomechanics.

[16]  G Ferrigno,et al.  Kinematical models to reduce the effect of skin artifacts on marker-based human motion estimation. , 2005, Journal of biomechanics.

[17]  Diane L. Damiano,et al.  Joint torques and co-contraction during gait for normal and Cerebral Palsy children , 1993 .

[18]  Georg N. Duda,et al.  The influence of alignment on the musculo-skeletal loading conditions at the knee , 2003, Langenbeck's Archives of Surgery.

[19]  A. Rozumalski,et al.  P041 A comparison of two functional methods for calculating joint centers and axes in a clinical setting , 2008 .

[20]  T P Andriacchi,et al.  Correcting for deformation in skin-based marker systems. , 2001, Journal of biomechanics.

[21]  Alberto Leardini,et al.  Soft tissue artifact compensation in knee kinematics by double anatomical landmark calibration: performance of a novel method during selected motor tasks , 2005, IEEE Transactions on Biomedical Engineering.

[22]  William R Taylor,et al.  Tibio-femoral joint contact forces in sheep. , 2006, Journal of biomechanics.

[23]  P. Costigan,et al.  Radiographic and non-invasive determination of the hip joint center location: effect on hip joint moments. , 1999, Clinical biomechanics.

[24]  Dan K Ramsey,et al.  Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo. , 2005, Gait & posture.

[25]  Min K. Chung,et al.  Soft tissue artifact compensation using displacement dependency between anatomical landmarks and skin markers – a preliminary study , 2009 .

[26]  M. Schwartz,et al.  A new method for estimating joint parameters from motion data. , 2004, Journal of biomechanics.

[27]  Velio Macellari,et al.  Skin marker artifacts in gait analysis , 1990 .

[28]  A Cappello,et al.  Skin movement artefact assessment and compensation in the estimation of knee-joint kinematics. , 1998, Journal of biomechanics.

[29]  P R Cavanagh,et al.  Accuracy of the functional method of hip joint center location: effects of limited motion and varied implementation. , 2001, Journal of biomechanics.

[30]  W. Taylor,et al.  Frontal plane alignment: an imageless method to predict the mechanical femoral-tibial angle (mFTA) based on functional determination of joint centres and axes. , 2010, Gait & posture.

[31]  William R Taylor,et al.  Tibio‐femoral loading during human gait and stair climbing , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[32]  M O Heller,et al.  Repeatability and reproducibility of OSSCA, a functional approach for assessing the kinematics of the lower limb. , 2010, Gait & posture.

[33]  F. Veldpaus,et al.  A least-squares algorithm for the equiform transformation from spatial marker co-ordinates. , 1988, Journal of biomechanics.

[34]  Morgan Sangeux,et al.  Validation of 3-D freehand ultrasound for the determination of the hip joint centre. , 2010, Gait & posture.

[35]  W. Taylor,et al.  A survey of formal methods for determining the centre of rotation of ball joints. , 2006, Journal of biomechanics.

[36]  Aurelio Cappozzo,et al.  An optimized protocol for hip joint centre determination using the functional method. , 2006, Journal of biomechanics.

[37]  Edward R. Valstar,et al.  Soft-tissue artefact assessment during step-up using fluoroscopy and skin-mounted markers. , 2008, Journal of biomechanics.

[38]  S Toksvig-Larsen,et al.  Validation of a functional method for the estimation of hip joint centre location. , 1999, Journal of biomechanics.