Subsurface Defect Detection in Metals with Pulsed Eddy Current

The eddy current (EC) method is traditionally used for open surface crack detection in metallic components. Subsurface voids in bulk metals can also be detected by the eddy current devices. Taking into consideration the skin effect in conductive materials, a lower frequency of electromagnetic excitation is used for a deeper penetration. A set of special specimens was designed and fabricated to investigate sensitivity to subsurface voids. Typically, flat bottom holes (FBHs) are used for subsurface defect simulation. This approach is not very representative of real defects for eddy current inspection because the FBH depth extends to the bottom of the specimen. Two‐layer specimens with finite depth FBHs were fabricated and scanned with conventional EC of variable frequency. Sensitivity and spatial resolution of EC diminish with flaw depth. The pulsed EC approach was applied for flaw detection at variable distance under the surface. The transient response from multi‐layer model was derived and compared to exp...