A Novel Neural Network Model for Blood Pressure Estimation Using Photoplethesmography without Electrocardiogram

The prevention, evaluation, and treatment of hypertension have attracted increasing attention in recent years. As photoplethysmography (PPG) technology has been widely applied to wearable sensors, the noninvasive estimation of blood pressure (BP) using the PPG method has received considerable interest. In this paper, a method for estimating systolic and diastolic BP based only on a PPG signal is developed. The multitaper method (MTM) is used for feature extraction, and an artificial neural network (ANN) is used for estimation. Compared with previous approaches, the proposed method obtains better accuracy; the mean absolute error is 4.02 ± 2.79 mmHg for systolic BP and 2.27 ± 1.82 mmHg for diastolic BP.

[1]  Jeffrey M. Hausdorff,et al.  Physionet: Components of a New Research Resource for Complex Physiologic Signals". Circu-lation Vol , 2000 .

[2]  Wen Jun Jiang,et al.  Data-driven estimation of blood pressure using photoplethysmographic signals , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[3]  Nigel H. Lovell,et al.  Improved Measurement of Blood Pressure by Extraction of Characteristic Features from the Cuff Oscillometric Waveform , 2015, Sensors.

[4]  A. Patzak,et al.  Continuous blood pressure measurement by using the pulse transit time: comparison to a cuff-based method , 2011, European Journal of Applied Physiology.

[5]  Shigeru Hisamichi,et al.  Home blood pressure measurement has a stronger predictive power for mortality than does screening blood pressure measurement: a population‐based observation in Ohasama, Japan , 1998, Journal of hypertension.

[6]  G. Moody,et al.  A database to support development and evaluation of intelligent intensive care monitoring , 1996, Computers in Cardiology 1996.

[7]  Matthew R. Weir,et al.  In the clinic: hypertension. , 2014, Annals of internal medicine.

[8]  J. Pépin,et al.  Pulse transit time: an appraisal of potential clinical applications , 1999, Thorax.

[9]  Zahari Taha,et al.  A review on non-invasive hypertension monitoring system by using photoplethysmography method , 2017 .

[10]  David J. Thomson,et al.  Time series analysis of Holocene climate data , 1990, Philosophical Transactions of the Royal Society of London. Series A, Mathematical and Physical Sciences.

[11]  Lawrence J Appel,et al.  Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. , 2005, Hypertension.

[12]  In-Young Kim,et al.  Comparative study on artificial neural network with multiple regressions for continuous estimation of blood pressure , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[13]  Donald B. Percival,et al.  Spectral Analysis for Physical Applications , 1993 .

[14]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[15]  D. Thomson,et al.  Spectrum estimation and harmonic analysis , 1982, Proceedings of the IEEE.

[16]  Y.T. Zhang,et al.  Continuous and noninvasive estimation of arterial blood pressure using a photoplethysmographic approach , 2003, Proceedings of the 25th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (IEEE Cat. No.03CH37439).

[17]  C. Ahlstrom,et al.  Noninvasive investigation of blood pressure changes using the pulse wave transit time: a novel approach in the monitoring of hemodialysis patients , 2005, Journal of Artificial Organs.

[18]  Gwanggil Jeon,et al.  On Using Maximum a Posteriori Probability Based on a Bayesian Model for Oscillometric Blood Pressure Estimation , 2013, Sensors.

[19]  J. Higgins,et al.  Blood-pressure measurement and classification in pregnancy , 2001, The Lancet.

[20]  D. Slepian Prolate spheroidal wave functions, fourier analysis, and uncertainty — V: the discrete case , 1978, The Bell System Technical Journal.

[21]  A S Berson,et al.  National Standard for Measurement of Resting and Ambulatory Blood Pressures With Automated Sphygmomanometers , 1993, Hypertension.

[22]  Daniel W. Jones,et al.  Recommendations for blood pressure measurement in humans and experimental animals: Part 1: blood pressure measurement in humans: a statement for professionals from the Subcommittee of Professional and Public Education of the American Heart Association Council on High Blood Pressure Research. , 2005, Hypertension.

[23]  Se Dong Min,et al.  Feasibility study for the non-invasive blood pressure estimation based on ppg morphology: normotensive subject study , 2017, BioMedical Engineering OnLine.

[24]  A. Ramachandra Rao,et al.  Multi-taper method of analysis of periodicities in hydrologic data , 2003 .

[25]  D. Thomson Quadratic-inverse spectrum estimates: applications to palaeoclimatology , 1990, Philosophical Transactions of the Royal Society of London. Series A: Physical and Engineering Sciences.

[26]  R. Kloner,et al.  Comparison of automated oscillometric versus auscultatory blood pressure measurement. , 2010, The American journal of cardiology.