Evaluation of energy consumption in small-scale agarwood distillation pot based on averaged control signal simulation

Water temperature of a hydro distillation process are represented by using first order plus dead time (FOPDT) model by performing a step test. From the model obtained, a PID controller have been implemented based on several tuning method includes Ziegler-Nichols, Cohen-Coon and Integral Square Error (ISE)-Load to enhance the performance of the system. In this study, a setpoint was set to 80°C and the comparative performance of PID controller with several tuning rules was evaluate and analyse via simulation. The analysis of the performance was depend on settling time, percentage of overshoot and rise time. Moreover, in this study, the average amount of control signal have been evaluated based on several tuning rules by using an integral control signal. The simulation result shows the ISE-Load that completed with minimum percentage of overshoot could result in best temperature control for hydro distillation process. However, in term of energy consumption, PID ZN gives lower energy usage.

[1]  Sankata B. Prusty,et al.  Comparative performance analysis of various tuning methods in the design of PID controller , 2015 .

[2]  Mohd Nasir Taib,et al.  Model Reference Adaptive Controller to regulate steam temperature in distillation process for essential oil extraction , 2011, 2011 IEEE 7th International Colloquium on Signal Processing and its Applications.

[3]  Zurina Zainal Abidin,et al.  Assessing the kinetic model of hydro-distillation and chemical composition of Aquilaria malaccensis leaves essential oil , 2017 .

[4]  M. N. Taib,et al.  Essential oil extraction with automated steam distillation: FMRLC for steam temperature regulation , 2012, 2012 IEEE International Conference on Control System, Computing and Engineering.

[5]  Mustafa Alpbaz Application of model predictive control and dynamic analysis to a pilot distillation column and experimental verification , 2002 .

[6]  Zhenyu Yang,et al.  Time-Delay System Identification Using Genetic Algorithm - Part Two: FOPDT/SOPDT Model Approximation , 2013, ICONS.

[7]  Mohd Nasir Taib,et al.  Characteristic of steam distillation pot with induction heating system based on step test response , 2011, 2011 IEEE Control and System Graduate Research Colloquium.

[8]  Mohd Nasir Taib,et al.  Robust steam temperature regulation for distillation of essential oil extraction process using hybrid fuzzy-PD plus PID controller , 2010 .

[9]  Zakiah Mohd Yusoff,et al.  Real time PID control for hydro-diffusion steam distillation essential oil extraction system using Gradient Descent tuning method , 2012, 2012 IEEE Control and System Graduate Research Colloquium.

[10]  Elham Almodaresi,et al.  Computing stability domains in the space of time delay and controller coefficients for FOPDT and SOPDT systems , 2014 .

[11]  Zakiah Mohd Yusoff,et al.  Steam temperature control of hydro-diffusion essential oil extraction system using hybrid-fuzzy plus PID controller , 2014, 2014 IEEE Conference on Systems, Process and Control (ICSPC 2014).

[12]  P. Kavitha,et al.  Camera gimbal stabilization using conventional PID controller and evolutionary algorithms , 2015, 2015 International Conference on Computer, Communication and Control (IC4).

[13]  C. Y. Patil,et al.  Design and Implementation of Stable PID Controller for Interacting Level Control System , 2016 .

[14]  M. N. Taib,et al.  Modeling of steam distillation pot with ARX model , 2012, 2012 IEEE 8th International Colloquium on Signal Processing and its Applications.

[15]  N. Ishak,et al.  Model Evaluation of a Steam Distillation Process for Steam Temperature Regulation , 2012, 2012 Third International Conference on Intelligent Systems Modelling and Simulation.

[16]  Anke Xue,et al.  Temperature Control of Industrial Coke Furnace Using Novel State Space Model Predictive Control , 2014, IEEE Transactions on Industrial Informatics.

[17]  Mohd Nasir Taib,et al.  Back calculation Anti Windup PID controller on Several Well-Known Tuning Method for Glycerin Bleaching Process Temperature Regulation , 2014 .

[18]  Furong Gao,et al.  Predictive control optimization based PID control for temperature in an industrial surfactant reactor , 2014 .