The Singular Value Filter: A General Filter Design Strategy for PCA-Based Signal Separation in Medical Ultrasound Imaging

A general filtering method, called the singular value filter (SVF), is presented as a framework for principal component analysis (PCA) based filter design in medical ultrasound imaging. The SVF approach operates by projecting the original data onto a new set of bases determined from PCA using singular value decomposition (SVD). The shape of the SVF weighting function, which relates the singular value spectrum of the input data to the filtering coefficients assigned to each basis function, is designed in accordance with a signal model and statistical assumptions regarding the underlying source signals. In this paper, we applied SVF for the specific application of clutter artifact rejection in diagnostic ultrasound imaging. SVF was compared to a conventional PCA-based filtering technique, which we refer to as the blind source separation (BSS) method, as well as a simple frequency-based finite impulse response (FIR) filter used as a baseline for comparison. The performance of each filter was quantified in simulated lesion images as well as experimental cardiac ultrasound data. SVF was demonstrated in both simulation and experimental results, over a wide range of imaging conditions, to outperform the BSS and FIR filtering methods in terms of contrast-to-noise ratio (CNR) and motion tracking performance. In experimental mouse heart data, SVF provided excellent artifact suppression with an average CNR improvement of 1.8 dB (P <; 0.05) with over 40% reduction (P <; 0.05) in displacement tracking error. It was further demonstrated from simulation and experimental results that SVF provided superior clutter rejection, as reflected in larger CNR values, when filtering was achieved using complex pulse-echo received data and non-binary filter coefficients.

[1]  Solange Akselrod,et al.  Stationary clutter rejection in echocardiography. , 2006, Ultrasound in medicine & biology.

[2]  Gregg E Trahey,et al.  BSS-based filtering of physiological and ARFI-induced tissue and blood motion. , 2003, Ultrasound in medicine & biology.

[3]  K.W. Ferrara,et al.  A new high resolution color flow system using an eigendecomposition-based adaptive filter for clutter rejection , 2001, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  Lasse Lovstakken,et al.  Eigen-based clutter filter design for ultrasound color flow imaging: a review , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[5]  John A Hossack,et al.  High frequency ultrasound imaging detects cardiac dyssynchrony in noninfarcted regions of the murine left ventricle late after reperfused myocardial infarction. , 2008, Ultrasound in medicine & biology.

[6]  Gregg E Trahey,et al.  Adaptive Clutter Filtering via Blind Source Separation for Two-Dimensional Ultrasonic Blood Velocity Measurement , 2002, Ultrasonic imaging.

[7]  T. Loupas,et al.  On the performance of regression and step-initialized IIR clutter filters for color Doppler systems in diagnostic medical ultrasound , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  R. Vautard,et al.  Singular spectrum analysis in nonlinear dynamics, with applications to paleoclimatic time series , 1989 .

[9]  John A Hossack,et al.  3D perfusion mapping in post-infarct mice using myocardial contrast echocardiography. , 2006, Ultrasound in medicine & biology.

[10]  John Gorcsan,et al.  Echocardiographic speckle tracking radial strain imaging to assess ventricular dyssynchrony in a pacing model of resynchronization therapy. , 2008, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[11]  Gianluca Bontempi,et al.  New Routes from Minimal Approximation Error to Principal Components , 2008, Neural Processing Letters.

[12]  Gregg E. Trahey,et al.  Quantitative Assessment of the Magnitude, Impact and Spatial Extent of Ultrasonic Clutter , 2008, Ultrasonic imaging.

[13]  W. C. de Albuquerque Pereira,et al.  Performance of ultrasound echo decomposition using singular spectrum analysis. , 2001, Ultrasound in medicine & biology.

[14]  R. Cobbold,et al.  Single-ensemble-based eigen-processing methods for color flow imaging - Part I. The Hankel-SVD filter , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  J. Hossack,et al.  3D prostate elastography: algorithm, simulations and experiments , 2007, Physics in medicine and biology.

[16]  J. Jensen,et al.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers , 1992, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[17]  K. Kristoffersen,et al.  Clutter filter design for ultrasound color flow imaging , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[18]  G.E. Trahey,et al.  A motion-based approach to abdominal clutter reduction , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[19]  K. Y. Esther Leung,et al.  Probabilistic framework for tracking in artifact-prone 3D echocardiograms , 2010, Medical Image Anal..

[20]  Meng-Lin Li Adaptive imaging using principal-component-synthesized aperture data , 2008, 2008 IEEE Ultrasonics Symposium.

[21]  F. Epstein,et al.  Quantification and MRI validation of regional contractile dysfunction in mice post myocardial infarction using high resolution ultrasound. , 2006, Ultrasound in medicine & biology.

[22]  Ian T. Jolliffe,et al.  Principal Component Analysis , 2002, International Encyclopedia of Statistical Science.

[23]  H. Torp,et al.  Clutter filters adapted to tissue motion in ultrasound color flow imaging , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Gregg E. Trahey,et al.  Blind source separation-based velocity estimation (BSSVE): simulation and clinical results , 2003, IEEE Symposium on Ultrasonics, 2003.

[25]  R. Cobbold,et al.  Single-ensemble-based eigen-processing methods for color flow imaging - Part II. The matrix pencil estimator , 2008, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[26]  H. Hotelling Analysis of a complex of statistical variables into principal components. , 1933 .

[27]  W F Walker,et al.  Complex principal components for robust motion estimation , 2010, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[28]  Wagner Coelho de Albuquerque Pereira,et al.  Characterization of in vitro healthy and pathological human liver tissue periodicity using backscattered ultrasound signals. , 2006, Ultrasound in medicine & biology.

[29]  P J Brands,et al.  Reduction of the Clutter Component in Doppler Ultrasound Signals Based on Singular Value Decomposition: A Simulation Study , 1997, Ultrasonic imaging.

[30]  Caterina M Gallippi,et al.  Robust principal component analysis and clustering methods for automated classification of tissue response to ARFI excitation. , 2008, Ultrasound in medicine & biology.