Finger-actuated, self-contained immunoassay cassettes

The building blocks for an inexpensive, disposable, luminescence-based microfluidic immunoassay cassette are described, and their integration in a point-of-care diagnostic system is demonstrated. Fluid motion in the cassette is driven by depressing finger-actuated pouches. All reagents needed for the immunoassay can be stored in the cassette in liquid form. Prior to use, the cassette consists of two separate parts. A top storage component contains pouches, sealed storage chambers, a metering chamber, and needle seats. The bottom processing component contains connection needles, a mixing chamber, and a detection chamber with immobilized proteins. Subsequent to sample introduction, the storage and processing components are mated. The needles form hydraulic connections between the two parts and, in some cases, close valves. The pouches are then actuated sequentially to induce flow of various reagents and facilitate process operations. The cassette is compatible with different detection modalities. Both a cassette with immunochromatographic-based detection and a cassette with microbead-based detection were constructed and evaluated. The immunochromatographic cassette was used to detect antibodies to HIV in saliva samples. The bead-based cassette was used to detect the proinflammatory chemokine IL-8. The experimental data demonstrates good repeatability and reasonable sensitivity.

[1]  Francis Barany,et al.  Polymerase chain reaction/ligase detection reaction/hybridization assays using flow-through microfluidic devices for the detection of low-abundant DNA point mutations. , 2006, Biosensors & bioelectronics.

[2]  P. Yager,et al.  Dry-Reagent Storage for Disposable Lab-On-Card Diagnosis of Enteric Pathogens , 2006, 1st Transdisciplinary Conference on Distributed Diagnosis and Home Healthcare, 2006. D2H2..

[3]  Haim H. Bau,et al.  The Kinematics of Bend-Induced Mixing in Micro-Conduits , 2003 .

[4]  Magnetic assembly of high-density DNA arrays for genomic analyses. , 2008, Analytical chemistry.

[5]  R. Sam Niedbala,et al.  Up-converting phosphor reporters for nucleic acid microarrays , 2001, Nature Biotechnology.

[6]  John T McDevitt,et al.  Disposable polydimethylsiloxane/silicon hybrid chips for protein detection. , 2005, Biosensors & bioelectronics.

[7]  Kabseog Kim,et al.  High aspect ratio tapered hollow metallic microneedle arrays with microfluidic interconnector , 2006 .

[8]  H. Tanke,et al.  A user-friendly, highly sensitive assay to detect the IFN- γ secretion by T cells , 2008 .

[9]  Alan Feinerman,et al.  A microfluidic approach to assembling ordered microsphere arrays , 2008 .

[10]  Xianbo Qiu,et al.  A timer-actuated immunoassay cassette for detecting molecular markers in oral fluids. , 2009, Lab on a chip.

[11]  Daniel Malamud,et al.  A Microfluidic System for Saliva‐Based Detection of Infectious Diseases , 2007, Annals of the New York Academy of Sciences.

[12]  Wen-Tso Liu,et al.  A spatially addressable bead-based biosensor for simple and rapid DNA detection. , 2008, Biosensors & bioelectronics.

[13]  Roland Zengerle,et al.  Microfluidic platforms for lab-on-a-chip applications. , 2007, Lab on a chip.

[14]  C T Lim,et al.  Bead-based microfluidic immunoassays: the next generation. , 2007, Biosensors & bioelectronics.

[15]  R C Anderson,et al.  A miniature integrated device for automated multistep genetic assays. , 2000, Nucleic acids research.

[16]  C. Klapperich,et al.  Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples , 2007, Biomedical microdevices.

[17]  Sundman Bo.,et al.  エレクトロウェッティングディスプレイの油脱ぬれパターンの観測と光学的意味 | 文献情報 | J-GLOBAL 科学技術総合リンクセンター , 2008 .

[18]  Shuichi Takayama,et al.  Computerized microfluidic cell culture using elastomeric channels and Braille displays. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[19]  Dong Sung Kim,et al.  Disposable integrated microfluidic biochip for blood typing by plastic microinjection moulding. , 2006, Lab on a chip.

[20]  D. Xing,et al.  Micropumps, microvalves, and micromixers within PCR microfluidic chips: Advances and trends. , 2007, Biotechnology advances.

[21]  N. A. Mufti,et al.  Upconverting phosphor reporters in immunochromatographic assays. , 2001, Analytical biochemistry.

[22]  Detlef Snakenborg,et al.  A fast and reliable way to establish fluidic connections to planar microchips , 2006 .

[23]  J B Shear,et al.  Development of multianalyte sensor arrays composed of chemically derivatized polymeric microspheres localized in micromachined cavities. , 2001, Journal of the American Chemical Society.

[24]  Regina Luttge,et al.  Silicon micromachined hollow microneedles for transdermal liquid transport , 2003 .

[25]  Shizhi Qian,et al.  A mathematical model of lateral flow bioreactions applied to sandwich assays. , 2003, Analytical biochemistry.

[26]  K. Gunderson,et al.  Illumina universal bead arrays. , 2006, Methods in enzymology.

[27]  D. Malamud,et al.  Point Detection of Pathogens in Oral Samples , 2005, Advances in dental research.

[28]  Zongyuan Chen,et al.  A disposable microfluidic cassette for DNA amplification and detection. , 2006, Lab on a chip.

[29]  Daniel Malamud,et al.  Rapid Assay Format for Multiplex Detection of Humoral Immune Responses to Infectious Disease Pathogens (HIV, HCV, and TB) , 2007, Annals of the New York Academy of Sciences.

[30]  H. Bau,et al.  A minute magneto hydro dynamic (MHD) mixer , 2001 .

[31]  D R Walt,et al.  High-density fiber-optic DNA random microsphere array. , 2000, Analytical chemistry.

[32]  Gwo-Bin Lee,et al.  Integrated microfluidic systems for cell lysis, mixing/pumping and DNA amplification , 2005 .

[33]  Sophia Adamia,et al.  An adaptable microvalving system for on-chip polymerase chain reactions. , 2005, Journal of immunological methods.

[34]  Multi-analyte immunoassay using cleavable tags and microchip micellular electrokinetic chromatography. , 2006, The Analyst.

[35]  W. Ching,et al.  Development of an Improved Rapid Lateral Flow Assay for the Detection of Orientia tsutsugamushi‐Specific IgG/IgM Antibodies , 2003, Annals of the New York Academy of Sciences.

[36]  Zongyuan Chen,et al.  Lab‐on‐a‐Chip Technologies for Oral‐Based Cancer Screening and Diagnostics , 2007, Annals of the New York Academy of Sciences.

[37]  Shizhi Qian,et al.  Analysis of lateral flow biodetectors: competitive format. , 2004, Analytical biochemistry.

[38]  David R Walt,et al.  Fiber-optic microsphere-based antibody array for the analysis of inflammatory cytokines in saliva. , 2009, Analytical chemistry.

[39]  Dong-il Dan Cho,et al.  In-plane single-crystal-silicon microneedles for minimally invasive microfluid systems , 2004 .