Synchronizing dynamic multileaf collimators for producing two-dimensional intensity-modulated fields with minimum beam delivery time.

PURPOSE Leaf motion synchronization of dynamic multileaf collimators (DMLC) for intensity-modulated radiotherapy (IMRT) is important in improving dose distribution and reducing "tongue-and-groove" effects for a prescribed intensity profile. Leaf synchronization could also be used in transforming a one-dimensional leaf-setting algorithm into a two-dimensional leaf-setting algorithm. In this work, we aim to develop a generalized leaf synchronization method for delivering IMRT with the minimized beam delivery time and the optimized subfield variations for a leaf-setting sequence. METHODS AND MATERIALS With the leaf synchronization procedure, all active MLC leaf pairs start and finish off a leaf sequence simultaneously. In this work, the MLC leaf pairs were synchronized under the condition that the resulting leaf sequence produces the desired intensity profile with the minimum beam delivery time. The parameter of the leaf synchronization function was determined through the least-square minimization of the area variations of all subfields within a leaf sequence. The leaf synchronization and optimization procedure were applied and analyzed for clinical relevant intensity profiles for treating the head-and-neck cancer patients using IMRT. RESULTS The total monitor units and the optimized beam delivery time of generating a two-dimensional intensity profile was proven through this work to be the global minimum of all leaf-setting sequences including the unsynchronized leaf-setting sequences. The optimized parameter for subfield variations of the synchronized leaf trajectories was found to be dependent on individual intensity profiles. For all our studied cases, the unsynchronized leaf trajectories always have significantly larger subfield variations than the synchronized leaf trajectories. CONCLUSION It is important and also feasible to synchronize and optimize dynamic MLC leaf motions while still keeping the total beam delivery time minimum for delivering arbitrary two-dimensional intensity-modulated fields.

[1]  J. V. van Santvoort,et al.  Dynamic multileaf collimation without 'tongue-and-groove' underdosage effects. , 1996, Physics in medicine and biology.

[2]  R Svensson,et al.  Simultaneous optimization of dynamic multileaf collimation and scanning patterns or compensation filters using a generalized pencil beam algorithm. , 1995, Medical physics.

[3]  S. Webb Configuration options for intensity-modulated radiation therapy using multiple static fields shaped by a multileaf collimator. , 1998, Physics in medicine and biology.

[4]  A L Boyer,et al.  An optimized leaf-setting algorithm for beam intensity modulation using dynamic multileaf collimators , 1998, Physics in medicine and biology.

[5]  D A Jaffray,et al.  The effects of intra-fraction organ motion on the delivery of dynamic intensity modulation. , 1998, Physics in medicine and biology.

[6]  R Svensson,et al.  An analytical solution for the dynamic control of multileaf collimators. , 1994, Physics in medicine and biology.

[7]  S. Spirou,et al.  Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators. , 1994, Medical physics.

[8]  D. Convery,et al.  The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation , 1992 .

[9]  J M Galvin,et al.  Combining multileaf fields to modulate fluence distributions. , 1993, International journal of radiation oncology, biology, physics.

[10]  C. Yu,et al.  A method for implementing dynamic photon beam intensity modulation using independent jaws and a multileaf collimator. , 1995, Physics in medicine and biology.

[11]  1044 Clinically practical intensity modulation for complex head and neck lesions using multiple, static MLC fields , 1997 .

[12]  S Webb,et al.  The effect of stair-step leaf transmission on the 'tongue-and-groove problem' in dynamic radiotherapy with a multileaf collimator. , 1997, Physics in medicine and biology.

[13]  A L Boyer,et al.  Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system. , 1997, Medical physics.

[14]  T LoSasso,et al.  Dosimetric verification of intensity-modulated fields. , 1996, Medical physics.

[15]  A L Boyer,et al.  Use of a multileaf collimator as a dynamic missing-tissue compensator. , 1996, Medical physics.

[16]  T. Bortfeld,et al.  X-ray field compensation with multileaf collimators. , 1994, International journal of radiation oncology, biology, physics.