Phase-to-Ground and Phase-to-Phase Sparkover Characteristics of External Insulation at the Entrance of an UHV Substation

For rational insulation design of an UHV substation, full-scale switching impulse tests of phase-to-ground (shielding ring-to-tower) and phase-to-phase (shielding ring-to-shielding ring) insulating clearance have been carried out in dry and wet conditions. In the tests, shielding rings that will be installed on bushings at actual UHV substations were used. The sparkover voltages depend on not only gap configurations but also the waveform of applied switching impulses; in other words, they show what we refer to as U-characteristics. Critical sparkover voltages are higher than those of rod-rod gaps by 20-25% in dry conditions and by 7-10% in wet conditions.

[1]  Isamu Kishizima,et al.  New Facilities for Phase-to-Phase Switching Impulse Tests and Some Test Results , 1984, IEEE Power Engineering Review.

[2]  Yoshinori Aihara Generalization of estimation method on phase-to-phase switching impulse flashover characteristics of long air gaps: Generalization of estimation method on phase-to-phase switching impulse flashover characteristics of long air gaps , 1989 .

[3]  L. E. Zaffanella,et al.  Phase-To-Ground and Phase-To-Phase Switching-Surge Flashover of External Insulation of UHV Stations , 1974 .

[4]  L. E. Zaffanella,et al.  Switching-Surge Results from Project UHV-Influence of Humidity and Grading Shields , 1971 .

[5]  L. E. Zaffanella,et al.  Switching-Surge Design of Towers for UHV Transmission , 1971 .

[6]  L. E. Zaffanella,et al.  Switching Surge Flashover of UHV Transmission Line Insulation , 1971 .

[7]  F.A.M. Rizk Influence of rain on switching impulse sparkover voltage of large-electrode air gaps , 1976, IEEE Transactions on Power Apparatus and Systems.

[8]  Yoshinori Aihara Generalization of Estimation Method on Phase-to-Phase Switching Impulse Flashover Characteristics of Long Air Gaps , 1989 .

[9]  F.A.M. Rizk,et al.  Critical switching impulse strength of phase-to-phase air insulation , 1993 .

[10]  H.M. Schneider,et al.  Switching-surge flashover characteristics of long sphere-plane gaps for UHV station design , 1975, IEEE Transactions on Power Apparatus and Systems.

[11]  G. Gallet,et al.  General expression for positive switching impulse strength valid up to extra long air gaps , 1975, IEEE Transactions on Power Apparatus and Systems.

[12]  Yoshihiro Ito,et al.  Impulse Flashover Characteristics of Long Air Gaps and Atmospheric Correction , 1978, IEEE Transactions on Power Apparatus and Systems.

[13]  W.C. Pokorny,et al.  UHV tower insulation parameters determined by full-scale testing , 1975, IEEE Transactions on Power Apparatus and Systems.

[14]  F.A.M. Rizk Effect of Large Electrodes on Sparkover Characteristics of Air Gaps and Station Insulators , 1978, IEEE Transactions on Power Apparatus and Systems.

[15]  E. Ohsaki,et al.  Effects of Parameters on The Phase-to-Phase Flashover Characteristics of UHV Transmission Lines , 1987, IEEE Power Engineering Review.

[16]  Georges Gallet,et al.  Analysis of the Switching Impulse Strength of Phase-To-Phase Air Gaps , 1978, IEEE Transactions on Power Apparatus and Systems.