Fully autonomous preload-sensitive control of implantable rotary blood pumps.

A pulsatility-based control algorithm with a self-adapting pulsatility reference value is proposed for an implantable rotary blood pump and is to be tested in computer simulations. The only input signal is the pressure difference across the pump, which is deduced from measurements of the pump's magnetic bearing. A pulsatility index (PI) is calculated as the mean absolute deviation from the mean pressure difference. As a second characteristic, the gradient of the PI with respect to the pump speed is derived. This pulsatility gradient (GPI) is used as the controlled variable to adjust the operating point of the pump when physiological variables such as the systemic arterial pressure, left ventricular contractility, or heart rate change. Depending on the selected mode of operation, the controller is either a linear controller or an extremum-seeking controller. A supervisory mechanism monitors the state of the system and projects the system into the region of convergence when necessary. The controller of the GPI continuously adjusts the reference value for PI. An underlying robust linear controller regulates the PI to the reference value in order to take into account changes in pulmonary venous return. As a means of reacting to sudden changes in the venous return, a suction detection mechanism was included. The control system is robustly stable within a wide range of physiological variables. All the clinician needs to do is to select between the two operating modes. No other adjustments are required. The algorithm showed promising results which encourage further testing in vitro and in vivo.

[1]  Johannes Müller,et al.  Physiological Control of a Rotary Left Ventricular Assist Device: Robust Control of Pressure Pulsatility with Suction Prevention and Suppression , 2009 .

[2]  Einly Lim,et al.  Noninvasive activity-based control of an implantable rotary blood pump: comparative software simulation study. , 2010, Artificial organs.

[3]  Nigel H. Lovell,et al.  Noninvasive Average Flow and Differential Pressure Estimation for an Implantable Rotary Blood Pump Using Dimensional Analysis , 2008, IEEE Transactions on Biomedical Engineering.

[4]  B. Lampe,et al.  Physiological control of a rotary blood pump with selectable therapeutic options: control of pulsatility gradient. , 2008, Artificial organs.

[5]  James F. Antaki,et al.  A Control System for Rotary Blood Pumps Based on Suction Detection , 2009, IEEE Transactions on Biomedical Engineering.

[6]  J.R. Boston,et al.  Control of heart assist devices , 2003, 42nd IEEE International Conference on Decision and Control (IEEE Cat. No.03CH37475).

[7]  Gang Tao,et al.  Modeling, Estimation, and Control of Human Circulatory System With a Left Ventricular Assist Device , 2007, IEEE Transactions on Control Systems Technology.

[8]  Yi Wu Adaptive Physiological Speed/Flow Control of Rotary Blood Pumps in Permanent Implantation Using Intrinsic Pump Parameters , 2009, ASAIO journal.

[9]  Seongjin Choi,et al.  Hemodynamic controller for left ventricular assist device based on pulsatility ratio. , 2007, Artificial organs.

[10]  S. L. Cloherty,et al.  Classification of physiologically significant pumping states in an implantable rotary blood pump: effects of cardiac rhythm disturbances. , 2007, Artificial organs.

[11]  Miroslav Krstic,et al.  Real-Time Optimization by Extremum-Seeking Control: Ariyur/Extremum Seeking , 2004 .

[12]  K Araki,et al.  The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function. , 2001, Artificial organs.

[13]  Georg Wieselthaler,et al.  Development of a suction detection system for axial blood pumps. , 2004, Artificial organs.

[14]  Nigel H Lovell,et al.  Identification and classification of physiologically significant pumping states in an implantable rotary blood pump. , 2006, Artificial organs.

[15]  Nigel H Lovell,et al.  Classification of Physiologically Significant Pumping States in an Implantable Rotary Blood Pump: Patient Trial Results , 2007, ASAIO journal.

[16]  Marwan A. Simaan,et al.  A discriminant-analysis-based suction detection system for rotary blood pumps , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[17]  Georg Wieselthaler,et al.  First clinical experience with an automatic control system for rotary blood pumps during ergometry and right-heart catheterization. , 2006, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[18]  O H Frazier,et al.  Use of a continuous-flow device in patients awaiting heart transplantation. , 2007, The New England journal of medicine.

[19]  Georg Wieselthaler,et al.  Development of a reliable automatic speed control system for rotary blood pumps. , 2005, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[20]  Georg Wieselthaler,et al.  Advanced suction detection for an axial flow pump. , 2006, Artificial organs.

[21]  James F. Antaki,et al.  A sensorless approach to control of a turbodynamic left ventricular assist system , 2001, IEEE Trans. Control. Syst. Technol..

[22]  Nader Moazami,et al.  Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. , 2009, Journal of the American College of Cardiology.

[23]  Paul Aurora,et al.  Registry of the International Society for Heart and Lung Transplantation: Twenty-sixth Official Adult Heart Transplant Report-2009. , 2009, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.