Because indocyanine green (ICG) dye is being used in tissue soldering, investigation of its degradation properties has become important. Studies have demonstrated the kinetics of indocyanine green degradation on light exposure. Temperature dependent changes have not been characterized. Since tissue soldering is a thermal process, we examined how absorption characteristics of aqueous ICG solutions change after heating. A 3.23 mM ICG stock solution in 2.5% human serum albumin (HSA) was prepared daily. From the stock solution, 1.5 ml samples were light shielded and heated to 100 degree(s)C for intervals of up to 5.5 hours. Control samples were maintained at room temperature. After heating, samples were diluted to 16.6 (mu) M ICG with 2.5% HSA for scanning. Absorbance from 200 to 900 nm was measured using an absorbance spectrophotometer. Peak absorption intensity decreased as heating time of samples increased from 1 to 5 hours, with the first consistently detectable change occurring after 1 hour. Absorption peak was stable at 805 - 808 nm with no novel peaks and absorbance magnitude was reduced only 2% over 1 hour. Lower temperatures more commonly seen in laser welding (60 - 80 degree(s)C) produced even smaller reductions in absorption intensity. Measurable thermal degradation of aqueous ICG solutions occurs at 100 degree(s)C after a period of hours. Therefore, thermal degradation of ICG in the context of tissue soldering is probably insignificant.
[1]
T. Flotte,et al.
Dye‐enhanced laser welding for skin closure
,
1992,
Lasers in surgery and medicine.
[2]
M C Oz,et al.
Changes in type I collagen following laser welding
,
1992,
Lasers in surgery and medicine.
[3]
F. Barbier,et al.
CHROMATOGRAPHY AND I.R. SPECTROGRAPHY OF INDOCYANINE GREEN.
,
1964,
Clinica chimica acta; international journal of clinical chemistry.
[4]
J Gathje,et al.
Stability studies on indocyanine green dye.
,
1970,
Journal of applied physiology.
[5]
Steven A. Schafer,et al.
Aggregation and degradation of indocyanine green
,
1994,
Photonics West - Lasers and Applications in Science and Engineering.
[6]
C. M. Leevy,et al.
Indocyanine green clearance as a test for hepatic function. Evaluation by dichromatic ear densitometry.
,
1967,
JAMA.
[7]
M C Oz,et al.
New technologies and future applications of surgical lasers. The right tool for the right job.
,
1992,
The Surgical clinics of North America.
[8]
C. S. Davidson,et al.
Indocyanine green: observations on its physical properties, plasma decay, and hepatic extraction.
,
1960,
The Journal of clinical investigation.
[9]
S. Libutti,et al.
A preliminary study of dye-enhanced laser photosclerosis.
,
1991,
Surgery.