A Microfluidic Long-Period Fiber Grating Sensor Platform for Chloride Ion Concentration Measurement

Optical fiber sensors based on waveguide technology are promising and attractive in chemical, biotechnological, agronomy, and civil engineering applications. A microfluidic system equipped with a long-period fiber grating (LPFG) capable of measuring chloride ion concentrations of several sample materials is presented. The LPFG-based microfluidic platform was shown to be effective in sensing very small quantities of samples and its transmitted light signal could easily be used as a measurand. The investigated sample materials included reverse osmosis (RO) water, tap water, dilute aqueous sample of sea sand soaked in RO water, aqueous sample of sea sand soaked in RO water, dilute seawater, and seawater. By employing additionally a chloride ion-selective electrode sensor for the calibration of chloride-ion concentration, a useful correlation (R2 = 0.975) was found between the separately-measured chloride concentration and the light intensity transmitted through the LPFG at a wavelength of 1,550 nm. Experimental results show that the sensitivity of the LPFG sensor by light intensity interrogation was determined to be 5.0 × 10−6 mW/mg/L for chloride ion concentrations below 2,400 mg/L. The results obtained from the analysis of data variations in time-series measurements for all sample materials show that standard deviations of output power were relatively small and found in the range of 7.413 × 10−5−2.769 × 10−3 mW. In addition, a fairly small coefficients of variations were also obtained, which were in the range of 0.03%–1.29% and decreased with the decrease of chloride ion concentrations of sample materials. Moreover, the analysis of stability performance of the LPFG sensor indicated that the random walk coefficient decreased with the increase of the chloride ion concentration, illustrating that measurement stability using the microfluidic platform was capable of measuring transmitted optical power with accuracy in the range of −0.8569 mW/ h to −0.5169 mW/ h. Furthermore, the bias stability was determined to be in the range of less than 6.134 × 10−8 mW/h with 600 s time cluster to less than 1.412 × 10−6 mW/h with 600 s time cluster. Thus, the proposed LPFG-based microfluidic platform has the potential for civil, chemical, biological, and biochemical sensing with aqueous solutions. The compact (3.5 × 4.2 cm), low-cost, real-time, small-volume (∼70 μL), low-noise, and high-sensitive chloride ion sensing system reported here could hopefully benefit the development and applications in the field of chemical, biotechnical, soil and geotechnical, and civil engineering.

[1]  An on-chip liquid tunable grating using multiphase droplet microfluidics , 2008 .

[2]  K. Hirao,et al.  Fabrication of long-period fiber gratings by focused irradiation of infrared femtosecond laser pulses. , 1999, Optics letters.

[3]  S. James,et al.  Optical fibre long-period grating sensors: characteristics and application , 2003 .

[4]  H J Shaw,et al.  Tunable mechanically induced long-period fiber gratings. , 2000, Optics letters.

[5]  J. Judkins,et al.  Long-period fiber gratings as band-rejection filters , 1995 .

[6]  Bai-ou Guan,et al.  Growth of long-period gratings in H2-loaded fiber after 193-nm UV inscription , 2000, IEEE Photonics Technology Letters.

[7]  J. Jensen,et al.  Photonic crystal fiber long-period gratings for biochemical sensing. , 2006, Optics express.

[8]  M. Fujimaki,et al.  Fabrication of long-period optical fiber gratings by use of ion implantation. , 2000, Optics letters.

[9]  W. Janusz,et al.  Optical aspects of Na+ ions adsorption on sol-gel porous films used in optical fiber sensors. , 2002, Journal of colloid and interface science.

[10]  R. Claus,et al.  Temperature-insensitive and strain-insensitive long-period grating sensors for smart structures , 1997 .

[11]  D. Y. Tang,et al.  Gratings written with tripled output of Q-switched Nd:YAG laser , 2000 .

[12]  Ole Bang,et al.  Towards biochips using microstructured optical fiber sensors , 2006, Analytical and bioanalytical chemistry.

[13]  Eric Bakker,et al.  Mechanistic insights into the development of optical chloride sensors based on the [9]mercuracarborand-3 ionophore. , 2003, Analytical chemistry.

[14]  Jonathan Rigelsford,et al.  Fiber Optic Smart Structures , 2001 .

[15]  James M. W. Brownjohn,et al.  Development of fiber Bragg grating sensors for monitoring civil infrastructure , 2005 .

[16]  N. Najafi,et al.  Measurement of density and chemical concentration using a microfluidic chip. , 2003, Lab on a chip.

[17]  E. Dianov,et al.  High-temperature stability of long-period fiber gratings produced using an electric arc , 2001 .

[18]  S. James,et al.  Fiber-optic liquid-level sensor using a long-period grating. , 2001, Optics letters.

[19]  Chien-Hsing Chen,et al.  A Multi-D-Shaped Optical Fiber for Refractive Index Sensing , 2010, Sensors.

[20]  I Klimant,et al.  Dual lifetime referencing as applied to a chloride optical sensor. , 2001, Analytical chemistry.

[21]  Jian-Neng Wang,et al.  Feasibility of Fiber Bragg Grating and Long-Period Fiber Grating Sensors under Different Environmental Conditions , 2010, Sensors.

[22]  M. Meyerhoff,et al.  Potentiometric anion selectivities of polymer membranes doped with indium(III)-porphyrins , 1991 .

[23]  Krishna Thyagarajan,et al.  Characterization and simulation of long period gratings fabricated using electric discharge , 2001 .

[24]  Craig A. Grimes,et al.  A Wireless, Passive, Magnetically-soft Harmonic Sensor for Monitoring Sodium Hypochlorite Concentrations in Water , 2003, Sensors (Basel, Switzerland).

[25]  Noel Zabaronick,et al.  Temperature-insensitive long-period gratings for strain and refractive index sensing , 1997, Smart Structures.

[26]  H. Stone,et al.  Microfluidics: Basic issues, applications, and challenges , 2001 .

[27]  Jian-Neng Wang,et al.  Measurement of chloride-ion concentration with long-period grating technology , 2007 .

[28]  P. Fonjallaz,et al.  Long-period fibre gratings written by CO2 exposure of H2-loaded, standard fibres , 2000 .

[29]  M. Meyerhoff,et al.  Optical chloride sensor based on dimer-monomer equilibrium of indium(III) octaethylporphyrin in polymeric film. , 2002, Analytical chemistry.

[30]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[31]  O. Bang,et al.  Highly sensitive refractometer with a photonic-crystal-fiber long-period grating. , 2007, Optics letters.

[32]  G. Nagy,et al.  Planar waveguide ion-selective sensors , 1997 .

[33]  F. Bright,et al.  A new ion sensor based on fiber optics. , 1988, Talanta.

[34]  Alan D. Kersey,et al.  Analysis of the response of long period fiber gratings to external index of refraction , 1998 .

[35]  G. Whitesides The origins and the future of microfluidics , 2006, Nature.

[36]  Kenneth T. V. Grattan,et al.  Chloride ion optical sensing using a long period grating pair , 2008 .

[37]  S. Yin,et al.  A highly sensitive long period grating based tunable filter using a unique double-cladding layer structure , 2001 .

[38]  Jaw-Luen Tang,et al.  Chemical Sensing Sensitivity of Long-Period Grating Sensor Enhanced by Colloidal Gold Nanoparticles , 2008, Sensors.

[39]  Chun-Ping Jen,et al.  A Novel Design of Grooved Fibers for Fiber-Optic Localized Plasmon Resonance Biosensors , 2009, Sensors.

[40]  Anna Grazia Mignani,et al.  Long period gratings as solution concentration sensors , 2001 .

[41]  Standard SpeciÞcation Format Guide and Test Procedure for Single-Axis Interferometric Fiber Optic Gyros , 1998 .

[42]  D. Diamond,et al.  Chloride selective calix[4]arene optical sensor combining urea functionality with pyrene excimer transduction. , 2006, Journal of the American Chemical Society.

[43]  Zabih Ghassemlooy,et al.  Modelling of long-period fibre grating response to refractive index higher than that of cladding , 2001 .

[44]  S. B. Lee,et al.  Displacements of the resonant peaks of a long-period fiber grating induced by a change of ambient refractive index. , 1997, Optics letters.

[45]  E. Bakker,et al.  Optical chloride sensor based on [9]mercuracarborand-3 with massively expanded measuring range. , 2004, Talanta.

[46]  Rino E. Kunz,et al.  Integrated optical sensors based on refractometry of ion-selective membranes , 1995 .

[47]  Hwa-Yaw Tam,et al.  Growth of long-period gratings in H 2 -loaded fiber after 193-nm UV inscription , 2000 .

[48]  K. Seiler,et al.  Reversible optical sensing membrane for the determination of chloride in serum , 1991 .

[49]  M. H. Noiré,et al.  A ferrous ion optical sensor based on fluorescence quenching , 1995 .

[50]  K. Xiao,et al.  A Chloride Ion-Selective Solvent Polymeric Membrane Electrode Based on a Hydrogen Bond Forming Ionophore , 1997 .

[51]  Ole Bang,et al.  Sensitivity of photonic crystal fiber grating sensors: biosensing, refractive index, strain, and temperature sensing , 2007, 0708.4382.

[52]  Angelo Maria Sabatini,et al.  A wavelet-based bootstrap method applied to inertial sensor stochastic error modelling using the Allan variance , 2006 .