Programmable bio-nano-chip system: a flexible point-of-care platform for bioscience and clinical measurements.

The development of integrated instrumentation for universal bioassay systems serves as a key goal for the lab-on-a-chip community. The programmable bio-nano-chip (p-BNC) system is a versatile multiplexed and multiclass chemical- and bio-sensing system for bioscience and clinical measurements. The system is comprised of two main components, a disposable cartridge and a portable analyzer. The customizable single-use plastic cartridges, which now can be manufactured in high volumes using injection molding, are designed for analytical performance, ease of use, reproducibility, and low cost. These labcard devices implement high surface area nano-structured biomarker capture elements that enable high performance signaling and are index-matched to real-world biological specimens. This detection modality, along with the convenience of on-chip fluid storage in blisters and self-contained waste, represents a standard process to digitize biological signatures at the point-of-care. A companion portable analyzer prototype has been developed to integrate fluid motivation, optical detection, and automated data analysis, and it serves as the human interface for complete assay automation. In this report, we provide a systems-level perspective of the p-BNC universal biosensing platform with an emphasis on flow control, device integration, and automation. To demonstrate the flexibility of the p-BNC, we distinguish diseased and non-case patients across three significant disease applications: prostate cancer, ovarian cancer, and acute myocardial infarction. Progress towards developing a rapid 7 minute myoglobin assay is presented using the fully automated p-BNC system.

[1]  Peidong Wang,et al.  An automated integrated platform for rapid and sensitive multiplexed protein profiling using human saliva samples. , 2014, Lab on a chip.

[2]  Amy E Herr,et al.  Microfluidic immunoassays as rapid saliva-based clinical diagnostics , 2007, Proceedings of the National Academy of Sciences.

[3]  John T. McDevitt,et al.  Porous Bead-Based Diagnostic Platforms: Bridging the Gaps in Healthcare , 2012, Sensors.

[4]  A. Manz,et al.  Micro total analysis systems. Latest advancements and trends. , 2006, Analytical chemistry.

[5]  Jesse V Jokerst,et al.  Programmable nano-bio-chips: multifunctional clinical tools for use at the point-of-care. , 2010, Nanomedicine.

[6]  Howard A. Stone,et al.  ENGINEERING FLOWS IN SMALL DEVICES , 2004 .

[7]  John T McDevitt,et al.  A Microchip CD4 Counting Method for HIV Monitoring in Resource-Poor Settings , 2005, PLoS medicine.

[8]  Samuel K Sia,et al.  Commercialization of microfluidic point-of-care diagnostic devices. , 2012, Lab on a chip.

[9]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[10]  Robert C. Bast,et al.  A Multiplexable, Microfluidic Platform for the Rapid Quantitation of a Biomarker Panel for Early Ovarian Cancer Detection at the Point-of-Care , 2014, Cancer Prevention Research.

[11]  Shirley Dex,et al.  JR 旅客販売総合システム(マルス)における運用及び管理について , 1991 .

[12]  Terry Kientz,et al.  A portable, integrated analyzer for microfluidic – based molecular analysis , 2011, Biomedical microdevices.

[13]  John T McDevitt,et al.  Effects of sample delivery on analyte capture in porous bead sensors. , 2012, Lab on a chip.

[14]  Andrew J. deMello,et al.  Microfluidics: Exploiting elephants in the room , 2010, Nature.

[15]  Lisa C Shriver-Lake,et al.  The Array Biosensor: Portable, Automated Systems , 2007, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[16]  Daniel Malamud,et al.  Finger-actuated, self-contained immunoassay cassettes , 2009, Biomedical microdevices.

[17]  W. Qiu,et al.  Integration of cell phone imaging with microchip ELISA to detect ovarian cancer HE4 biomarker in urine at the point-of-care. , 2011, Lab on a chip.

[18]  Lisa Lafleur,et al.  Progress toward multiplexed sample-to-result detection in low resource settings using microfluidic immunoassay cards. , 2012, Lab on a chip.

[19]  Jesse V Jokerst,et al.  Nano-bio-chips for high performance multiplexed protein detection: determinations of cancer biomarkers in serum and saliva using quantum dot bioconjugate labels. , 2009, Biosensors & bioelectronics.

[20]  Daniel Malamud,et al.  An integrated, self-contained microfluidic cassette for isolation, amplification, and detection of nucleic acids , 2010, Biomedical microdevices.

[21]  Jesse V Jokerst,et al.  Location of biomarkers and reagents within agarose beads of a programmable bio-nano-chip. , 2011, Small.

[22]  Tae-Hyeong Kim,et al.  Fully integrated lab-on-a-disc for simultaneous analysis of biochemistry and immunoassay from whole blood. , 2011, Lab on a chip.

[23]  John T McDevitt,et al.  Hot embossed polyethylene through-hole chips for bead-based microfluidic devices. , 2013, Biosensors & bioelectronics.

[24]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[25]  J. McDevitt,et al.  Modeling analyte transport and capture in porous bead sensors. , 2012, Analytical chemistry.

[26]  J. McDevitt,et al.  Programmable nano-bio-chip sensors: analytical meets clinical. , 2010, Analytical chemistry.

[27]  Steve Feng,et al.  Rapid imaging, detection and quantification of Giardia lamblia cysts using mobile-phone based fluorescent microscopy and machine learning. , 2015, Lab on a chip.

[28]  Luke P. Lee,et al.  Innovations in optical microfluidic technologies for point-of-care diagnostics. , 2008, Lab on a chip.

[29]  M. Plebani,et al.  Diagnostic strategies using myoglobin measurement in myocardial infarction. , 1998, Clinica chimica acta; international journal of clinical chemistry.

[30]  S. Lehmann,et al.  Protein biochip systems for the clinical laboratory , 2005, Clinical chemistry and laboratory medicine.

[31]  Gaetano Borriello,et al.  Towards a point-of-care diagnostic system: automated analysis of immunoassay test data on a cell phone , 2011, NSDR '11.

[32]  Lyle E. Yarnell,et al.  Automated digital microfluidic platform for magnetic-particle-based immunoassays with optimization by design of experiments. , 2013, Analytical chemistry.

[33]  John T McDevitt,et al.  Application of programmable bio-nano-chip system for the quantitative detection of drugs of abuse in oral fluids. , 2015, Drug and alcohol dependence.

[34]  Mehmet Toner,et al.  Advancing the speed, sensitivity and accuracy of biomolecular detection using multi-length-scale engineering. , 2014, Nature nanotechnology.

[35]  Samuel K Sia,et al.  Lab-on-a-chip devices for global health: past studies and future opportunities. , 2007, Lab on a chip.

[36]  Yi Guo,et al.  Competitive volumetric bar-chart chip with real-time internal control for point-of-care diagnostics. , 2015, Analytical chemistry.

[37]  Andreas Manz,et al.  Micro total analysis systems: latest achievements. , 2008, Analytical chemistry.

[38]  John Spertus,et al.  Use of saliva-based nano-biochip tests for acute myocardial infarction at the point of care: a feasibility study. , 2009, Clinical chemistry.

[39]  T. N. Vijaykumar,et al.  Software-programmable continuous-flow multi-purpose lab-on-a-chip , 2013, Microfluidics and Nanofluidics.

[40]  LinLin Shen,et al.  A review on Gabor wavelets for face recognition , 2006, Pattern Analysis and Applications.

[41]  G. Whitesides The origins and the future of microfluidics , 2006, Nature.

[42]  Tassaneewan Laksanasopin,et al.  Mobile device for disease diagnosis and data tracking in resource-limited settings. , 2013, Clinical chemistry.

[43]  J. Heath,et al.  Chemical methods for the simultaneous quantitation of metabolites and proteins from single cells. , 2015, Journal of the American Chemical Society.

[44]  W. Marsden I and J , 2012 .

[45]  M. Waterman,et al.  Serum myoglobin level as diagnostic test in patients with acute myocardial infarction. , 1977, British heart journal.

[46]  T. Groth,et al.  The value of serum myoglobin determinations in the early diagnosis of acute myocardial infarction. , 2009, Acta medica Scandinavica.

[47]  James McCord,et al.  Ninety-Minute Exclusion of Acute Myocardial Infarction By Use of Quantitative Point-of-Care Testing of Myoglobin and Troponin I , 2001, Circulation.

[48]  Kristen L. Helton,et al.  Microfluidic Overview of Global Health Issues Microfluidic Diagnostic Technologies for Global Public Health , 2006 .

[49]  Luke P. Lee,et al.  Stand-alone self-powered integrated microfluidic blood analysis system (SIMBAS). , 2011, Lab on a chip.

[50]  M. Bergeron,et al.  Diagnosing infections--current and anticipated technologies for point-of-care diagnostics and home-based testing. , 2010, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[51]  Jeffrey T. Ives,et al.  Rapid Multiplexed Immunoassay for Simultaneous Serodiagnosis of HIV-1 and Coinfections , 2011, Journal of Clinical Microbiology.

[52]  Alex Nemiroski,et al.  Universal mobile electrochemical detector designed for use in resource-limited applications , 2014, Proceedings of the National Academy of Sciences.

[53]  John T McDevitt,et al.  Programmable bio-nanochip technology for the diagnosis of cardiovascular disease at the point-of-care. , 2012, Methodist DeBakey cardiovascular journal.