N-Channel field-effect transistors with floating gates for extracellular recordings.

A field-effect transistor (FET) for recording extracellular signals from electrogenic cells is presented. The so-called floating gate architecture combines a complementary metal oxide semiconductor (CMOS)-type n-channel transistor with an independent sensing area. This concept allows the transistor and sensing area to be optimised separately. The devices are robust and can be reused several times. The noise level of the devices was smaller than of comparable non-metallised gate FETs. In addition to the usual drift of FET devices, we observed a long-term drift that has to be controlled for future long-term measurements. The device performance for extracellular signal recording was tested using embryonic rat cardiac myocytes cultured on fibronectin-coated chips. The extracellular cell signals were recorded before and after the addition of the cardioactive isoproterenol. The signal shapes of the measured action potentials were comparable to the non-metallised gate FETs previously used in similar experiments. The fabrication of the devices involved the process steps of standard CMOS that were necessary to create n-channel transistors. The implementation of a complete CMOS process would facilitate the integration of the logical circuits necessary for signal pre-processing on a chip, which is a prerequisite for a greater number of sensor spots in future layouts.

[1]  A. Errachid,et al.  ION-SENSITIVE FIELD-EFFECT TRANSISTORS FABRICATED IN A COMMERCIAL CMOS TECHNOLOGY , 1999 .

[2]  A. Offenhäusser,et al.  Electrical recordings from rat cardiac muscle cells using field-effect transistors. , 1999, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[3]  B. Eversmann,et al.  A 128 × 128 CMOS bio-sensor array for extracellular recording of neural activity , 2003 .

[4]  D. Schmitt-Landsiedel,et al.  A 128 /spl times/ 128 CMOS bio-sensor array for extracellular recording of neural activity , 2003, 2003 IEEE International Solid-State Circuits Conference, 2003. Digest of Technical Papers. ISSCC..

[5]  J. Meindl,et al.  A process for the combined fabrication of ion sensors and CMOS circuits , 1988, IEEE Electron Device Letters.

[6]  M. Esashi,et al.  Methods of isfet fabrication , 1981 .

[7]  Andreas Offenhäusser,et al.  64-Channel extended gate electrode arrays for extracellular signal recording , 2003 .

[8]  Bradley A. Minch,et al.  Analysis, synthesis, and implementation of networks of multiple-input translinear elements , 1997 .

[9]  Marc Madou,et al.  Imperfections in and ion diffusion through oxide layers on silicon , 1980 .

[10]  P. Fromherz,et al.  A neuron-silicon junction: a Retzius cell of the leech on an insulated-gate field-effect transistor. , 1991, Science.

[11]  J. V. Spiegel,et al.  The extended gate chemically sensitive field effect transistor as multi-species microprobe☆ , 1983 .

[12]  M Krause,et al.  Validation of the use of field effect transistors for extracellular signal recording in pharmacological bioassays. , 2001, Journal of pharmacological and toxicological methods.

[13]  J. Shappir,et al.  Depletion type floating gate p-channel MOS transistor for recording action potentials generated by cultured neurons. , 2004, Biosensors & bioelectronics.

[14]  Andreas Offenhäusser,et al.  Long-term recording system based on field-effect transistor arrays for monitoring electrogenic cells in culture , 1998 .

[15]  Piet Bergveld,et al.  Extracellular Potential Recordings by Means of a Field Effect Transistor Without Gate Metal, Called OSFET , 1976, IEEE Transactions on Biomedical Engineering.

[16]  M Krause,et al.  Cardiomyocyte-transistor-hybrids for sensor application. , 2001, Biosensors & bioelectronics.

[17]  S. M. Sze,et al.  Physics of semiconductor devices , 1969 .

[18]  Yael Nemirovsky,et al.  1/f Noise in CMOS transistors for analog applications from subthreshold to saturation , 1998 .

[19]  A. Offenhäusser,et al.  Field-effect transistor array for monitoring electrical activity from mammalian neurons in culture. , 1997, Biosensors & bioelectronics.

[20]  A. Offenhäusser,et al.  Neuronal cells cultured on modified microelectronic device surfaces , 1995 .

[21]  J. Pine Recording action potentials from cultured neurons with extracellular microcircuit electrodes , 1980, Journal of Neuroscience Methods.

[22]  Andreas Offenhäusser,et al.  Micropatterned Substrates for the Growth of Functional Neuronal Networks of Defined Geometry , 2003, Biotechnology progress.

[23]  J. G. Smith,et al.  Active microelectrode array to record from the mammalian central nervous systemin vitro , 1981, Medical and Biological Engineering and Computing.

[24]  G. Gross,et al.  Transparent indium-tin oxide electrode patterns for extracellular, multisite recording in neuronal cultures , 1985, Journal of Neuroscience Methods.

[25]  R. J. Huber,et al.  Electrostatically protected ion sensitive field effect transistors , 1984 .

[26]  M. Denyer,et al.  Bioassay development: The implications of cardiac myocyte motility in vitro , 1999, In Vitro Cellular & Developmental Biology - Animal.

[27]  J. W. Parce,et al.  Detection of cell-affecting agents with a silicon biosensor. , 1989, Science.