Interaction vertex imaging (IVI) for carbon ion therapy monitoring: a feasibility study

Proton imaging can be seen as a powerful technique for online monitoring of ion range during carbon ion therapy irradiations. Indeed, a large number of secondary protons are created during nuclear reactions, and many of these protons are likely to escape from the patient even for deep-seated tumors, carrying accurate information on the reaction vertex position. Two detection techniques have been considered: (i) double-proton detection by means of two forward-located trackers and (ii) single-proton detection in coincidence with the incoming carbon ion detected by means of a beam hodoscope. Geant4 simulations, validated by proton yield measurements performed at GANIL and GSI, show that ion-range monitoring is accessible on a pencil-beam basis with the single-proton imaging technique. Millimetric precision on the Bragg peak position is expected in the ideal case of homogeneous targets. The uncertainties in more realistic conditions should be investigated, in particular the influence of tissue heterogeneity in the very last part of the ion path (about 20 mm).

[1]  Takashi NAKAMURA,et al.  Development of General-Purpose Particle and Heavy Ion Transport Monte Carlo Code , 2002 .

[2]  A Mairani,et al.  Benchmarking nuclear models of FLUKA and GEANT4 for carbon ion therapy , 2010, Physics in medicine and biology.

[3]  H Paganetti,et al.  Monte Carlo patient study on the comparison of prompt gamma and PET imaging for range verification in proton therapy , 2011, Physics in medicine and biology.

[4]  Denis Dauvergne,et al.  Real-time monitoring of the Bragg-peak position in ion therapy by means of single photon detection , 2010, Radiation and environmental biophysics.

[5]  Dieter Schardt,et al.  Heavy-ion tumor therapy: Physical and radiobiological benefits , 2010 .

[6]  David Sarrut,et al.  Optimization of GEANT4 settings for Proton Pencil Beam Scanning simulations using GATE , 2010 .

[7]  O Jäkel,et al.  Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimization. , 2000, Physics in medicine and biology.

[8]  Arnaud Guertin,et al.  Nuclear reaction measurements of 95MeV/u 12C interactions on PMMA for hadrontherapy , 2011 .

[9]  T. Inaniwa,et al.  Spatial fragment distribution from a therapeutic pencil-like carbon beam in water , 2005, Physics in medicine and biology.

[10]  T. Koi,et al.  Geometry and physics of the Geant4 toolkit for high and medium energy applications , 2009 .

[11]  C Villagrasa,et al.  Physical models implemented in the GEANT4-DNA extension of the GEANT-4 toolkit for calculating initial radiation damage at the molecular level. , 2011, Radiation protection dosimetry.

[12]  Harald Paganetti,et al.  Relative biological effectiveness (RBE) values for proton beam therapy. , 2002, International journal of radiation oncology, biology, physics.

[13]  A. Brahme,et al.  Ion beam transport in tissue-like media using the Monte Carlo code SHIELD-HIT. , 2004, Physics in medicine and biology.

[14]  W. Greiner,et al.  Nuclear fragmentation reactions in extended media studied with Geant4 toolkit , 2009, 0911.2017.

[15]  D. Schardt,et al.  Secondary beam fragments produced by 200 MeV u−1 12C ions in water and their dose contributions in carbon ion radiotherapy , 2008 .

[16]  Chan Hyeong Kim,et al.  Prompt gamma measurements for locating the dose falloff region in the proton therapy , 2006 .

[17]  J. Hüfner Heavy fragments produced in proton-nucleus and nucleus-nucleus collisions at relativistic energies☆ , 1985 .

[18]  F. Orsini,et al.  First test results Of MIMOSA-26, a fast CMOS sensor with integrated zero suppression and digitized output , 2009, 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC).

[19]  U. Amaldi,et al.  Advanced Quality Assurance for CNAO , 2010 .

[20]  W. G. Lynch Nuclear Fragmentation in Proton- and Heavy-Ion-Induced Reactions , 1987 .

[21]  Katia Parodi,et al.  Charged hadron tumour therapy monitoring by means of PET , 2004 .

[22]  W. Greiner,et al.  Comparative study of depth-dose distributions for beams of light and heavy nuclei in tissue-like media , 2007, 0704.2519.

[23]  J. Ziegler,et al.  SRIM – The stopping and range of ions in matter (2010) , 2010 .

[24]  M. Bajard,et al.  Monitoring the Bragg peak location of 73 MeV/u carbon ions by means of prompt γ-ray measurements , 2008, 0809.0185.