Analysis of trace metals in water samples using NOBIAS chelate resins by HPLC and ICP-MS.

The pre-concentration of major constituents is crucial to accurate and precise determination of trace metals in water samples by inductively coupled plasma mass spectrometry (ICP-MS). In this work, NOBIAS chelate resins were used in the sample concentration for both HPLC and ICP-MS detection. 4-(2-Pyridylazo) resorcinol (PAR) was selected as a precolumn chelating reagent for this research. 520 nm wavelength was used as to minimize the peak of PAR and to reduce baseline noise for HPLC analysis. The sample pre-treatment step was achieved by enrichment and Cd(II), Co(II), Cu(II), Mn(II), Ni(IV), Pb(II), and Zn(II) were detected in the bottled water and tap water samples. The results of two detection methods of ICP-MS and HPLC were compared. Results showed that by acquiring 50-time pre-concentrates of test samples using 250 mg of the Nobias-chelate PA1 chelating resin, the metal contents could be accurately detected using both ICP-MS and HPLC. And the approach of HPLC enables the quantitative detection of bottled water and tap water at different concentrations with determination coefficient (R2) greater than 0.9990. This simple and cost-effective quantitative detection approach using NOBIAS chelate resins and HPLC may widen the application of NOBIAS chelate resins for quantitative detection of more water samples.

[1]  Jing Zhang,et al.  Recovery of Trace Metal Isotopes in Seawater Samples Using Multifunctional Neem (Azadirachta indica) Biosorbent: A Comparison with Monofunctional NOBIAS–Chelate–PA1 Resin , 2013 .

[2]  Q. Fernaǹdo,et al.  Potentiometric Investigation of the Metal Complexes of 1-(2-Pyridylazo)-2-naphthol and 4-(2-Pyridylazo)resorcinol. , 1962 .

[3]  J. Ståhlberg Retention models for ions in chromatography. , 1999, Journal of chromatography. A.

[4]  J. Vincent Recent advances in the nutritional biochemistry of trivalent chromium , 2004, Proceedings of the Nutrition Society.

[5]  M. Y. Khuhawar,et al.  Simultaneous high performance liquid chromatographic determination of vanadium, nickel, iron and copper in crude petroleum oils using bis(acetylpivalylmethane)ethylenediimine as a complexing reagent. , 1996, Talanta.

[6]  T. Hirata,et al.  A simple and rapid method for isotopic analysis of nickel, copper, and zinc in seawater using chelating extraction and anion exchange. , 2017, Analytica chimica acta.

[7]  Lars Jarup,et al.  Hazards of heavy metal contamination. , 2003 .

[8]  T. Kono,et al.  Multielemental determination of GEOTRACES key trace metals in seawater by ICPMS after preconcentration using an ethylenediaminetriacetic acid chelating resin. , 2008, Analytical chemistry.

[9]  A. Campiglia,et al.  Water analysis of the sixteen environmental protection agency-polycyclic aromatic hydrocarbons via solid-phase nanoextraction-gas chromatography/mass spectrometry. , 2014, Journal of chromatography. A.

[10]  P. Andersson,et al.  Determination of Nd isotopes in water: a chemical separation technique for extracting Nd from seawater using a chelating resin. , 2011, Analytical chemistry.

[11]  K. Murphy,et al.  Direct determination of P, V, Mn, As, Mo, Ba and U in seawater by SF-ICP-MS , 2007 .

[12]  N. Gros,et al.  Ionic composition of seawaters and derived saline solutions determined by ion chromatography and its relation to other water quality parameters. , 2008, Journal of chromatography. A.

[13]  E. Boyle,et al.  Low Blank Preconcentration Technique for the Determination of Lead, Copper, and Cadmium in Small-Volume Seawater Samples by Isotope Dilution ICPMS. , 1997, Analytical chemistry.

[14]  N. Lihareva,et al.  Extraction-spectrophotometric determination of zinc(ii) with 4-(2-pyridylazo)-resorcinol and a quaternary ammonium salt. , 1976, Talanta.

[15]  P. Janoš,et al.  An ion-exchange separation of metal cations on a C-18 column coated with dodecylsulphate. , 1992, Talanta.

[16]  J. Lima,et al.  Determination of transition metals in human hair by high-performance liquid chromatography using sodium hexadecane-sulfonate coated columns. , 1999, Talanta.

[17]  M. Trojanowicz,et al.  Flow-injection sample preconcentration for ion-pair chromatography of trace metals in waters. , 2003, Water research.

[18]  K. Robards,et al.  Metal determination and metal speciation by liquid chromatography. A review , 1991 .

[19]  G. Tao,et al.  Dithizone functionalized CdSe/CdS quantum dots as turn-on fluorescent probe for ultrasensitive detection of lead ion. , 2013, Journal of hazardous materials.

[20]  M. Akashi,et al.  Synthesis of hydrophilic macroporous chelating polymers and their versatility in the preconcentration of metals in seawater samples , 2006 .

[21]  J. Cullen,et al.  Determination of Mn, Fe, Ni, Cu, Zn, Cd and Pb in seawater using offline extraction and triple quadrupole ICP-MS/MS , 2018 .

[22]  Baoxing Wang,et al.  Determination of transition metal ions in tobacco as their 2-(2-quinolinylazo)-5-dimethylaminophenol derivatives using reversed-phase liquid chromatography with UV-VIS detection. , 2002, Journal of chromatography. A.

[23]  C. Fraga,et al.  Relevance, essentiality and toxicity of trace elements in human health. , 2005, Molecular aspects of medicine.

[24]  P. Wang,et al.  Recent applications of high-performance liquid chromatography to the analysis of metal complexes. , 1997, Journal of chromatography. A.

[25]  E. Achterberg,et al.  Automated preconcentration of Fe, Zn, Cu, Ni, Cd, Pb, Co, and Mn in seawater with analysis using high-resolution sector field inductively-coupled plasma mass spectrometry. , 2017, Analytica chimica acta.

[26]  P. Trivedi,et al.  Expression of a rice Lambda class of glutathione S-transferase, OsGSTL2, in Arabidopsis provides tolerance to heavy metal and other abiotic stresses. , 2013, Journal of hazardous materials.

[27]  P. Oteiza,et al.  Metals in neurodegeneration: involvement of oxidants and oxidant-sensitive transcription factors. , 2004, Molecular aspects of medicine.