Efficiency Analysis of the Main Components of a Vertical Closed-Loop System in a Borehole Heat Exchanger

In vertical closed-loop systems, it is common to use single or double U-tube heat exchangers separated by longitudinal spacers. In addition, the helical-shaped pipe is another configuration that requires lower drilling lengths but it is less used. The aim of the present research is to study the influence of these components on the total efficiency of a borehole heat exchanger (BHE). Thus, the differences between using single/double U-tubes (with or without spacers) and helical pipes are analysed in terms of efficiency. Through different laboratory tests, a small vertical closed-loop system was simulated in order to analyse all these possible configurations. The grouting materials and the temperatures of the ground were modified at the same time in these tests. Regarding the heat exchange process between the ground and the heat carrier fluid, it must be highlighted that the best results were obtained for the helical-shaped pipe configuration. Some of the improvements offered by this heat exchanger typology with respect to the vertical configuration is that a lower drilling depth is required even it requires a larger diameter. This leads to significant economic savings in the performing drilling process. Finally, it is also worth noting the importance of using spacers in vertical U-tubes and that no improvements have been found regarding the use of single or double configuration of U-tubes. Thanks to the laboratory results derived from this study it is possible to establish the optimum behaviour pattern for the entire vertical closed-loop systems.

[1]  Hangseok Choi,et al.  Characteristics of thermally-enhanced bentonite grouts for geothermal heat exchanger in South Korea , 2010 .

[2]  D.D.L. Chung,et al.  Effect of sand addition on the specific heat and thermal conductivity of cement , 2000 .

[3]  Daniel Castro-Fresno,et al.  Study of different grouting materials used in vertical geothermal closed-loop heat exchangers , 2013 .

[4]  Jalaluddin,et al.  Thermal performance investigation of several types of vertical ground heat exchangers with different operation mode , 2012 .

[5]  Sangwoo Park,et al.  Constructability and heat exchange efficiency of large diameter cast-in-place energy piles with various configurations of heat exchange pipe , 2015 .

[6]  Michele De Carli,et al.  Performance analysis of short helical borehole heat exchangers via integrated modelling of a borefield and a heat pump: A case study , 2013 .

[7]  Michele De Carli,et al.  Analysis of short helical and double U-tube borehole heat exchangers: A simulation-based comparison , 2013 .

[8]  Georgios A. Florides,et al.  Ground heat exchangers—A review of systems, models and applications , 2007 .

[9]  A. Philippacopoulos,et al.  PERFORMANCE CHARACTERISTICS AND MODELLING OF CEMENTITIOUS GROUTS FOR GEOTHERMAL HEAT PUMPS , 2000 .

[10]  Pedro Carrasco García,et al.  Analysis and study of different grouting materials in vertical geothermal closed-loop systems , 2017 .

[11]  Hans Hoes,et al.  Experimental performance of borehole heat exchangers and grouting materials for ground source heat pumps , 2012 .

[12]  Hongxing Yang,et al.  Vertical-borehole ground-coupled heat pumps: A review of models and systems , 2010 .

[13]  R. Bertani,et al.  Summary of EGC 2019 Country Update Reports on Geothermal Energy in Europe , 2013 .

[14]  Weibo Yang,et al.  Laboratory investigations of the thermal performance of an energy pile with spiral coil ground heat exchanger , 2016 .

[15]  Taeyeon Kim,et al.  Applications of building-integrated coil-type ground-coupled heat exchangers—Comparison of performances of vertical and horizontal installations , 2015 .

[16]  Michele De Carli,et al.  Analysis of operating modes of a ground source heat pump with short helical heat exchangers , 2015 .

[17]  Ingrid Stober,et al.  Geothermal Energy: From Theoretical Models to Exploration and Development , 2013 .

[18]  Paul Christodoulides,et al.  Single and double U-tube ground heat exchangers in multiple-layer substrates , 2013 .

[19]  Francesco Tinti,et al.  An innovative Borehole Heat Exchanger configuration with improved heat transfer , 2013 .

[20]  Pedro Carrasco García,et al.  Thermal conductivity map of the Avila region (Spain) based on thermal conductivity measurements of different rock and soil samples , 2017 .

[21]  Chanjuan Han,et al.  Sensitivity analysis of a vertical geothermal heat pump system , 2016 .

[22]  Luka Boban,et al.  Comparison of different methods for ground thermal properties determination in a clastic sedimentary environment , 2016 .

[23]  Pedro Carrasco García,et al.  Analysis of the process of design of a geothermal installation , 2016 .

[24]  Seung-Rae Lee,et al.  Evaluation of thermal efficiency in different types of horizontal ground heat exchangers , 2015 .

[25]  M. Allan Thermal conductivity of cementitious grouts for geothermal heat pumps. Progress report FY 1997 , 1997 .

[26]  Hyunku Park,et al.  Case study of heat transfer behavior of helical ground heat exchanger , 2012 .

[27]  Gianpiero Colangelo,et al.  CFD simulations of horizontal ground heat exchangers: A comparison among different configurations , 2012 .