Fast and quiet MRI using a swept radiofrequency.

A novel fast and quiet method of magnetic resonance imaging (MRI) is introduced which creates new opportunities for imaging in medicine and materials science. The method is called SWIFT, sweep imaging with Fourier transformation. In SWIFT, time-domain signals are acquired in a time-shared manner during a swept radiofrequency excitation of the nuclear spins. With negligible time between excitation and signal acquisition, new possibilities exist for imaging objects consisting of spins with extremely fast transverse relaxation rates, such as macromolecules, semi-solids, and quadrupolar nuclei. The field gradient used for spatial-encoding is not pulsed on and off, but rather is stepped in orientation in an incremental manner, which results in low acoustic noise. This unique acquisition method is expected to be relatively insensitive to sample motion, which is important for imaging live objects. Additionally, the frequency-swept excitation distributes the signal energy in time and thus dynamic range requirements for proper signal digitization are reduced compared with conventional MRI. For demonstration, images of a plastic object and cortical bone are shown.

[1]  R. K. Wangsness,et al.  Shapes of Nuclear Induction Signals , 1948 .

[2]  E. Purcell,et al.  Resonance Absorption by Nuclear Magnetic Moments in a Solid , 1946 .

[3]  T. Farrar Chapter 5 – Fourier Transform NMR , 1971 .

[4]  Richard R. Ernst,et al.  Sensitivity Enhancement in Magnetic Resonance , 1966 .

[5]  Mark Bydder,et al.  Magnetic Resonance: An Introduction to Ultrashort TE (UTE) Imaging , 2003, Journal of computer assisted tomography.

[6]  A. Macovski,et al.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application]. , 1991, IEEE transactions on medical imaging.

[7]  R. R. Ernst,et al.  Application of Fourier Transform Spectroscopy to Magnetic Resonance , 1966 .

[8]  Paul A Bottomley,et al.  Measuring human cardiac tissue sodium concentrations using surface coils, adiabatic excitation, and twisted projection imaging with minimal T2 losses , 2005, Journal of magnetic resonance imaging : JMRI.

[9]  G. Bodenhausen,et al.  Principles of nuclear magnetic resonance in one and two dimensions , 1987 .

[10]  Richard R. Ernst,et al.  Magnetic resonance with stochastic excitation , 1970 .

[11]  H. C. Torrey Transient Nutations in Nuclear Magnetic Resonance , 1949 .

[12]  Michael Garwood,et al.  Improved Performance of Frequency-Swept Pulses Using Offset-Independent Adiabaticity , 1996 .

[13]  L DelaBarre,et al.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR. , 2001, Journal of magnetic resonance.

[14]  J. Ferretti,et al.  Rapid scan Fourier transform NMR spectroscopy , 1974 .

[15]  R Kaiser,et al.  Coherent spectrometry with noise signals , 1970 .

[16]  J G Pipe,et al.  Spatial Encoding and Reconstruction in MRI with Quadratic Phase Profiles , 1995, Magnetic resonance in medicine.

[17]  R. R. Ernst,et al.  Interference effects in NMR correlation spectroscopy of coupled spin systems , 1976 .

[18]  Andrew J Fagan,et al.  Development of a 3-D, multi-nuclear continuous wave NMR imaging system. , 2005, Journal of magnetic resonance.

[19]  J M Pauly,et al.  Lung parenchyma: projection reconstruction MR imaging. , 1991, Radiology.

[20]  Michael Garwood,et al.  Improved gradient‐echo 3D magnetic resonance imaging using pseudo‐echoes created by frequency‐swept pulses , 2006, Magnetic resonance in medicine.

[21]  R. Norberg,et al.  FREE-INDUCTION DECAYS IN SOLIDS , 1957 .

[22]  W. W. Hansen,et al.  The Nuclear Induction Experiment , 1946 .

[23]  B. Blümich,et al.  Hadamard NMR imaging with slice selection. , 1996, Magnetic resonance imaging.

[24]  D. Rutledge,et al.  Signal treatment and signal analysis in NMR , 1996 .

[25]  J. Dadok,et al.  Correlation NNW spectroscopy , 1974 .

[26]  P. Bendel Biomedical applications of 10B and 11B NMR , 2005, NMR in biomedicine.

[27]  Spectrometer for stochastic solid-state nuclear magnetic resonance spectroscopy , 2001 .

[28]  Hoult,et al.  Selective spin inversion in nuclear magnetic resonance and coherent optics through an exact solution of the Bloch-Riccati equation. , 1985, Physical review. A, General physics.

[29]  S Hafner,et al.  Fast imaging in liquids and solids with the Back-projection Low Angle ShoT (BLAST) technique. , 1994, Magnetic resonance imaging.

[30]  R. E. Richards,et al.  Fourier transform NMR spectroscopy , 1977, Nature.

[31]  D. Madio,et al.  Ultra‐fast imaging using low flip angles and fids , 1995, Magnetic resonance in medicine.

[32]  B. Blümich,et al.  Stochastic spectroscopic imaging , 1992 .

[33]  R. Kim,et al.  Physiological basis for potassium (39K) magnetic resonance imaging of the heart. , 1999, Circulation research.

[34]  J. P. Jones,et al.  Foundations of Medical Imaging , 1993 .