Enhancement of Power System Oscillation Damping using Fuzzy Inference System based Coordinated Design of SSSC Controllers

Nowadays, Flexible AC Transmission System (FACTS) devices are widely used in different power systems. As the application of these technologies increases, possible interferences in operational tasks of controllers and inappropriate oscillations in different situations like fault and post-fault conditions make the coordination of their controllers inevitable. In this paper, a Fuzzy Inference System (FIS) based coordinated design of Static Synchronous Series Compensator (SSSC) controllers is presented and discussed. The main advantages of the proposed scheme are good damping and overshoot reduction of oscillations and thereby improving power oscillations damping. The Trajectory Sensitivities (TS) analysis, which is a time domain method to evaluate the stability of a system in the presence of disturbances, is also used to assess the validity of this coordinated controller design method. The comparison of simulation results with the conventional Proportional-Integral-Derivative (PID) controller based system validates the effectiveness of this design.

[1]  Tomonobu Senjyu,et al.  Enhancement of transient stability of multi-machine power systems by using fuzzy-genetic controller , 2000, J. Intell. Fuzzy Syst..

[2]  K. W. Wang,et al.  Multimachine eigenvalue sensitivities of power system parameters , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[3]  H. W. Ngan,et al.  Coordinated power control strategy for flexible AC transmission system , 1999, Proceedings of the IEEE 1999 International Conference on Power Electronics and Drive Systems. PEDS'99 (Cat. No.99TH8475).

[4]  G. Andersson,et al.  Coordinated control of FACTS devices based on optimal power flow , 2005, Proceedings of the 37th Annual North American Power Symposium, 2005..

[5]  Arindam Ghosh,et al.  Improvement of transient stability of power systems with STATCOM-controller using trajectory sensitivity , 2011 .

[6]  R. Sreerama Kumar,et al.  ANN based adaptive control coordination of PSSs and FACTS devices in multi-machine power systems , 2010, 2010 Modern Electric Power Systems.

[7]  K. K. Sen SSSC-static synchronous series compensator: theory, modeling, and application , 1998 .

[8]  Mariesa L. Crow,et al.  Performance Indices for the Dynamic Performance of FACTS and FACTS with Energy Storage , 2004 .

[9]  Tomonobu Senjyu,et al.  Stabilization of multi-machine power system with facts equipment applying fuzzy control , 1998, J. Intell. Fuzzy Syst..

[10]  N. K. Sharma,et al.  A Novel Placement Strategy for FACTS Controllers , 2002, IEEE Power Engineering Review.

[11]  Tony B. Nguyen,et al.  Dynamic security-constrained rescheduling of power systems using trajectory sensitivities , 2003 .

[12]  G. Andersson,et al.  Coordinated control of FACTS devices in power systems for security enhancement , 2007, 2007 iREP Symposium - Bulk Power System Dynamics and Control - VII. Revitalizing Operational Reliability.

[13]  R. Yokoyama,et al.  Coordinated control of PSS and FACTS for poor damping long-term oscillations in multi-machine power systems , 2004, 39th International Universities Power Engineering Conference, 2004. UPEC 2004..

[14]  Rachid Cherkaoui,et al.  Congestion Management Using Coordinated Control of FACTS Devices and Load Shedding , 2005 .

[15]  Yong Chang Design of HVDC and SVC Coordinate Damping Controller Based on Wide Area Signal , 2006 .

[16]  Ian A. Hiskens,et al.  Trajectory Sensitivity Analysis of Hybrid Systems , 2000 .

[17]  Prechanon Kumkratug Coordination of Series and Shunt Flexible AC Transmission System Devices Based Voltage Source Converter for Improving Power System Stability , 2011 .

[18]  Istvan Erlich,et al.  Coordination Between Transient and Damping Controller for Series Facts Devices Using ANFIS Technology , 2003 .

[19]  Arturo Roman Messina,et al.  Inter-area Oscillations in Power Systems , 2009 .

[20]  M. A. Pai,et al.  A new approach to dynamic security assessment using trajectory sensitivities , 1997 .

[21]  Navid Razmjooy,et al.  Application of fuzzy subtractive clustering for optimal transient performance of automatic generation control in restructured power system , 2014, J. Intell. Fuzzy Syst..

[22]  I. Erlich,et al.  Simultaneous coordinated tuning of PSS and FACTS damping controllers in large power systems , 2005, IEEE Transactions on Power Systems.

[23]  I. Hiskens,et al.  Power system applications of trajectory sensitivities , 2002, 2002 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.02CH37309).

[24]  Narayana Prasad Padhy,et al.  Power-system Stability Improvement by PSO Optimized SSSC-based Damping Controller , 2008 .

[25]  N.G. Caicedo,et al.  Proposal for the Solution of Voltage Stability Using Coordination of Facts Devices , 2006, 2006 IEEE/PES Transmission & Distribution Conference and Exposition: Latin America.

[26]  Nishi Sharma,et al.  A Comprehensive Survey of Optimal Placement and Coordinated Control Techniques of FACTS Controllers in Multi-Machine Power System Environments , 2010 .

[27]  Narayana Prasad Padhy,et al.  Coordinated Design of TCSC Controller and PSS Employing Particle Swarm Optimization Technique , 2007 .

[28]  A. Oudalov,et al.  Power System Stability Enhancement Using ANN Based Coordinated Emergency Control System , 2007, 2007 IEEE Lausanne Power Tech.

[29]  Derong Liu,et al.  Stability and Control of Dynamical Systems with Applications , 2003 .

[30]  Juan M. Ramirez,et al.  PSS and FDS simultaneous tuning , 2004 .