X-Ray Phase-Contrast CT of a Pancreatic Ductal Adenocarcinoma Mouse Model

To explore the potential of grating-based x-ray phase-contrast computed tomography (CT) for preclinical research, a genetically engineered mouse model of pancreatic ductal adenocarcinoma (PDAC) was investigated. One ex-vivo mouse specimen was scanned with different grating-based phase-contrast CT imaging setups covering two different settings: i) high-resolution synchrotron radiation (SR) imaging and ii) dose-reduced imaging using either synchrotron radiation or a conventional x-ray tube source. These experimental settings were chosen to assess the potential of phase-contrast imaging for two different types of application: i) high-performance imaging for virtual microscopy applications and ii) biomedical imaging with increased soft-tissue contrast for in-vivo applications. For validation and as a reference, histological slicing and magnetic resonance imaging (MRI) were performed on the same mouse specimen. For each x-ray imaging setup, attenuation and phase-contrast images were compared visually with regard to contrast in general, and specifically concerning the recognizability of lesions and cancerous tissue. To quantitatively assess contrast, the contrast-to-noise ratios (CNR) of selected regions of interest (ROI) in the attenuation images and the phase images were analyzed and compared. It was found that both for virtual microscopy and for in-vivo applications, there is great potential for phase-contrast imaging: in the SR-based benchmarking data, fine details about tissue composition are accessible in the phase images and the visibility of solid tumor tissue under dose-reduced conditions is markedly superior in the phase images. The present study hence demonstrates improved diagnostic value with phase-contrast CT in a mouse model of a complex endogenous cancer, promoting the use and further development of grating-based phase-contrast CT for biomedical imaging applications.

[1]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[2]  S. Figueroa,et al.  TLD assessment of mouse dosimetry during microCT imaging. , 2008, Medical physics.

[3]  Franz Pfeiffer,et al.  Multimodal imaging of human cerebellum - merging X-ray phase microtomography, magnetic resonance microscopy and histology , 2012, Scientific Reports.

[4]  Ke Li,et al.  Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography. , 2010, Medical physics.

[5]  Franz Pfeiffer,et al.  Experimental results from a preclinical X-ray phase-contrast CT scanner , 2012, Proceedings of the National Academy of Sciences.

[6]  T. Bormann,et al.  Three-dimensional registration of tomography data for quantification in biomaterials science , 2012 .

[7]  Arne Tapfer,et al.  Recent developments in x-ray Talbot interferometry at ESRF-ID19 , 2010, Optical Engineering + Applications.

[8]  Atsushi Momose,et al.  Demonstration of X-Ray Talbot Interferometry , 2003 .

[9]  K. Uesugi,et al.  Phase-contrast X-ray microtomography of mouse fetus , 2012, Biology Open.

[10]  Franz Pfeiffer,et al.  High-resolution tomographic imaging of a human cerebellum: comparison of absorption and grating-based phase contrast , 2010, Journal of The Royal Society Interface.

[11]  Franz Pfeiffer,et al.  X-ray phase radiography and tomography of soft tissue using grating interferometry. , 2008, European journal of radiology.

[12]  Paola Coan,et al.  Evaluation of imaging performance of a taper optics CCD; FReLoN' camera designed for medical imaging. , 2006, Journal of synchrotron radiation.

[13]  R. Schmid,et al.  Concomitant pancreatic activation of Kras(G12D) and Tgfa results in cystic papillary neoplasms reminiscent of human IPMN. , 2007, Cancer cell.

[14]  F. Pfeiffer,et al.  Trimodal low-dose X-ray tomography , 2012, Proceedings of the National Academy of Sciences.

[15]  Franz Pfeiffer,et al.  Soft-tissue phase-contrast tomography with an x-ray tube source , 2009, Physics in medicine and biology.

[16]  E. Petricoin,et al.  Preinvasive and invasive ductal pancreatic cancer and its early detection in the mouse. , 2003, Cancer cell.

[17]  Daniel Jeanmonod,et al.  Strain fields in histological slices of brain tissue determined by synchrotron radiation-based micro computed tomography , 2008, Journal of Neuroscience Methods.

[18]  Franz Pfeiffer,et al.  Development of a prototype gantry system for preclinical x-ray phase-contrast computed tomography. , 2011, Medical physics.

[19]  Dan Stutman,et al.  Talbot phase-contrast x-ray imaging for the small joints of the hand , 2011, Physics in medicine and biology.

[20]  Richard J. Fitzgerald,et al.  Phase‐Sensitive X‐Ray Imaging , 2000 .

[21]  Gerhard Martens,et al.  Contrast-to-noise in X-ray differential phase contrast imaging , 2011 .

[22]  Atsushi Momose,et al.  Phase Tomography by X-ray Talbot Interferometry for Biological Imaging , 2006 .

[23]  Robert D. Speller,et al.  The Dexela 2923 CMOS X-ray detector: A flat panel detector based on CMOS active pixel sensors for medical imaging applications , 2012 .

[24]  A Bravin,et al.  High-resolution brain tumor visualization using three-dimensional x-ray phase contrast tomography , 2007, Physics in medicine and biology.

[25]  Thomas Köhler,et al.  Noise properties of grating-based x-ray phase contrast computed tomography. , 2011, Medical physics.

[26]  A. Momose Recent Advances in X-ray Phase Imaging , 2005 .

[27]  C. David,et al.  The First Analysis and Clinical Evaluation of Native Breast Tissue Using Differential Phase-Contrast Mammography , 2011, Investigative radiology.

[28]  Franz Pfeiffer,et al.  Toward Clinical X-ray Phase-Contrast CT: Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen , 2010, Investigative radiology.

[29]  William H. Press,et al.  Numerical Recipes 3rd Edition: The Art of Scientific Computing , 2007 .

[30]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[31]  O. Bunk,et al.  Hard x-ray phase tomography with low-brilliance sources. , 2007, Physical review letters.

[32]  Franz Pfeiffer,et al.  Assessment of grating-based X-ray phase-contrast CT for differentiation of invasive ductal carcinoma and ductal carcinoma in situ in an experimental ex vivo set-up , 2013, European Radiology.

[33]  Emilio Quaia,et al.  Mammography with synchrotron radiation: first clinical experience with phase-detection technique. , 2011, Radiology.