Prediction of retention times for anions in linear gradient elution ion chromatography with hydroxide eluents using artificial neural networks.

The feasibility of using an artificial neural network (ANN) to predict the retention times of anions when eluted from a Dionex AS11 column with linear hydroxide gradients of varying slope was investigated. The purpose of this study was to determine whether an ANN could be used as the basis of a computer-assisted optimisation method for the selection of optimal gradient conditions for anion separations. Using an ANN with a (1, 10, 19) architecture and a training set comprising retention data obtained with three gradient slopes (1.67, 2.50 and 4.00 mM/min) between starting and finishing conditions of 0.5 and 40.0 mM hydroxide, respectively, retention times for 19 analyte anions were predicted for four different gradient slopes. Predicted and experimental retention times for 133 data points agreed to within 0.08 min and percentage normalised differences between the predicted and experimental data averaged 0.29% with a standard deviation of 0.29%. ANNs appear to be a rapid and accurate method for predicting retention times in ion chromatography using linear hydroxide gradients.

[1]  D. Jenke,et al.  Models for prediction of retention in nonsuppressed ion chromatography , 1984 .

[2]  M. Maruo,et al.  Ion chromatographic elution behaviour and prediction of the retention of inorganic monovalent anions using a phosphate eluent , 1989 .

[3]  J. Wolff,et al.  Une généralisation de la théorie de brönsted en chimie analytique , 1947 .

[4]  D. Jenke Modeling of analyte behavior in indirect photometric chromatography , 1984 .

[5]  P. Haddad,et al.  Critical comparison of retention models for the optimisation of the separation of anions in ion chromatography. II. Suppressed anion chromatography using carbonate eluents. , 1999, Journal of chromatography. A.

[6]  T. Hoover Multiple Eluent and pH Effects on Ion Chromatography of Phosphate and Arsenate , 1982 .

[7]  P. Haddad,et al.  Critical comparison of retention models for optimisation of the separation of anions in ion chromatography: III. Anion chromatography using hydroxide eluents on a Dionex AS11 stationary phase , 1999 .

[8]  D. Jenke Prediction of Retention Characteristics of Multiprotic Anions in Ion Chromatography , 1994 .

[9]  M. Tavares,et al.  Systematic approach to the separation of mono- and hydroxycarboxylic acids in environmental samples by ion chromatography and capillary electrophoresis , 1998 .

[10]  P. Haddad,et al.  Critical comparison of retention models for optimisation of the separation of anions in ion chromatography. I. Non-Suppressed anion chromatography using phthalate eluents and three different stationary phases , 1999 .

[11]  O. Horváth,et al.  Prediction of Retention for Halide Anions and Oxoanions in Suppressed Ion Chromatography Using Multiple Species Eluent , 1995 .

[12]  Robert A. Jacobs,et al.  Increased rates of convergence through learning rate adaptation , 1987, Neural Networks.

[13]  Jerry A. Darsey,et al.  Opening up the black box of artificial neural networks , 1994 .

[14]  W. R. Jones,et al.  Gradient elution of anions in single column ion chromatography , 1988 .

[15]  Paul R. Haddad,et al.  Prediction of retention times for anions in ion chromatography using Artificial Neural Networks , 1999 .

[16]  Paul R. Haddad,et al.  Ion chromatography: principles and applications: (Journal of Chromatography Library, Vol. 46), Elsevier, Amsterdam, 1990 (ISBN 0-444-88232-4). xxi + 776 pp. Price Dfl. 335.00/US $ 171.75 , 1991 .

[17]  C. Pohl,et al.  Gradient elution in ion chromatography , 1987 .

[18]  P. Haddad,et al.  Computer-assisted optimization of eluent concentration and pH in ion chromatography , 1984 .

[19]  D. Jenke,et al.  Optimization of anion separation by nonsuppressed ion chromatography , 1984 .