Assessment of Indoor Air Quality in Renovated Buildings of Liepāja Municipality

Abstract The research of five educational institution buildings and three municipality department buildings were carried out in Liepāja municipality, Latvia. Aim of the study is to draw attention to finding balance among energy efficiency, thermal comfort and indoor air quality dilemma. The research of recently renovated public sector buildings was done. The combination of factors that form microclimate and indoor air quality are described in the paper. Emphasis is put on a person's ability to perform mental tasks in regards of changes in thermal comfort and air quality. Surveys of buildings’ inhabitants and economic aspects of human productivity changes were carried out in the research. Also four ventilation scenarios have been modelled and economic benefits of each scenario have been assessed. Different air exchange rates can make 19% human productivity improvement. Using ventilation systems as it is designed already gives economic benefit and not all the buildings need additional investments for new system implementation. The economic benefit in four buildings is more than 20 000 euro already in second year. The priority for planning, designing and managing education institution buildings should be indoor environment and thermal comfort of inhabitant.

[1]  Francisco J. Aguilar,et al.  Operation and Energy Efficiency of a Hybrid Air Conditioner Simultaneously Connected to the Grid and to Photovoltaic Panels , 2014 .

[2]  William J. Fisk,et al.  Changing ventilation rates in U.S. offices: Implications for health, work performance, energy, and associated economics , 2012 .

[3]  Giuliano Dall'O',et al.  Potential and limits to improve energy efficiency in space heating in existing school buildings in northern Italy , 2013 .

[4]  J. Lodge Air quality guidelines for Europe: WHO regional publications, European series, No. 23, World Health Organization, 1211 Geneva 27, Switzerland; WHO publications center USA, 49 Sheridan Avenue, Albany, NY 12210, 1987, xiii + 426 pp. price: Sw. fr. 60 , 1988 .

[5]  Risto Kosonen,et al.  The effect of perceived indoor air quality on productivity loss , 2004 .

[6]  Triantafyllos Makarios,et al.  Seismic non-linear static new method of spatial asymmetric multi-storey r/c buildings. , 2012 .

[7]  Peteris Shipkovs,et al.  Solar Thermal Cooling on the Northernmost Latitudes , 2015 .

[8]  Monica Paciuk,et al.  Improving energy performance of school buildings while ensuring indoor air quality ventilation , 2007 .

[9]  Theodoros Theodosiou,et al.  Energy, comfort and indoor air quality in nursery and elementary school buildings in the cold climatic zone of Greece , 2008 .

[10]  Refrigerating ASHRAE handbook and product directory /published by the American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc , 1977 .

[11]  R. Kosonen,et al.  Assessment of productivity loss in air-conditioned buildings using PMV index , 2004 .

[12]  P. O. Fanger,et al.  Thermal comfort: analysis and applications in environmental engineering, , 1972 .

[13]  O Seppänen,et al.  Ventilation and performance in office work. , 2006, Indoor air.

[14]  Woods Je Cost avoidance and productivity in owning and operating buildings. , 1989 .