Probabilistic seismic assessment of seismically isolated electrical transformers considering vertical isolation and vertical ground motion

Abstract This study presents a probabilistic response analysis of seismically isolated electrical transformers with emphasis on comparing the performance of equipment that are non-isolated to equipment that are isolated only in the horizontal direction or are isolated by a three-dimensional isolation system. The performance is assessed by calculating the probability of failure as function of the seismic intensity with due consideration of: (a) horizontal and vertical ground seismic motions, (b) displacement capacity of the seismic isolation system, (c) limit states of electrical bushings, (d) details of construction of the isolation system, (e) weight of the isolated transformer, and (f) bushing geometry and configuration. Calculations of the probability of failure within the lifetime of isolated and non-isolated transformers at selected locations are also performed. The results of this study demonstrate that seismic isolation systems can improve the seismic performance for a wide range of parameters and that systems which isolate in both the horizontal and vertical directions can be further effective. The seismic assessment methodology presented can be used for: (a) deciding on the need to use seismic isolation and selecting the properties of the isolation system for transformers depending on the design limits, location, and configuration of transformer and (b) calculating the mean annual frequency of functional failure and the corresponding probability of failure over the lifetime of the equipment. The results may also be used to assess the seismic performance of electric transmission networks under scenarios of component failures.

[1]  Anshel J. Schiff Proposed Change to IEEE Qualification of Transformers and Their Bushings , 2009 .

[2]  Maria Koliou,et al.  Seismic Response of High-Voltage Transformer-Bushing Systems Incorporating Flexural Stiffeners I: Numerical Study , 2013 .

[3]  Andrew S. Whittaker,et al.  Earthquake Performance of Porcelain Transformer Bushings , 2004 .

[4]  S. T. Mau,et al.  Analytical and Experimental Seismic Studies of Transformers Isolated with Friction Pendulum System and Design Aspects , 2001 .

[5]  Masayoshi Nakashima,et al.  Full‐scale shaking table test of a base‐isolated medical facility subjected to vertical motions , 2013 .

[6]  T. Fujita,et al.  A study on earthquake observation record in the building using the three-dimensional seismic isolation system , 2012 .

[7]  Anshel J. Schiff GUIDE TO POST-EARTHQUAKE INVESTIGATION OF LIFELINES , 1998 .

[8]  Andrei M. Reinhorn,et al.  Shake Table Testing of Triple Friction Pendulum Isolators under Extreme Conditions 13-0011.pdf , 2013 .

[9]  Michael C. Constantinou,et al.  Model of Triple Friction Pendulum Bearing for General Geometric and Frictional Parameters and for Uplift Conditions 13-0010.pdf , 2013 .

[10]  Daniel M. Fenz Development, implementation and verification of dynamic analysis models for multi-spherical sliding bearings , 2008 .

[11]  Roberto Villaverde,et al.  Ground motion amplification at flange level of bushings mounted on electric substation transformers , 2001 .

[12]  Dimitrios Vamvatsikos,et al.  Incremental dynamic analysis , 2002 .

[13]  Farzin Zareian,et al.  Decision support for conceptual performance‐based design , 2006 .

[14]  Hiroshi Kuwahara,et al.  Studies on Aseismic Isolation Device for Electric Substation Equipment , 1987 .

[15]  Yoshiharu Shumuta Practical seismic upgrade strategy for substation equipment based on performance indices , 2007 .

[16]  Michael C. Constantinou,et al.  Modeling Triple Friction Pendulum Bearings for Response-History Analysis , 2008 .

[17]  Dohwan Kong Evaluation and protection of high voltage electrical equipment against severe shock and vibrations , 2010 .

[18]  M. Constantinou,et al.  A model of triple friction pendulum bearing for general geometric and frictional parameters , 2016 .

[19]  Gilberto Mosqueda,et al.  Seismic Response of Ceiling/Sprinkler Piping Nonstructural Systems in NEES TIPS/NEES Nonstructural/NIED Collaborative Tests on a Full Scale 5-Story Building , 2012 .

[20]  Leon Kempner,et al.  Seismic Performance Evaluation of High Voltage Transformer Bushings , 2010 .

[21]  Andre Filiatrault,et al.  Experimental Seismic Response of High-Voltage Transformer-Bushing Systems , 2005 .

[22]  Masanobu Shinozuka,et al.  Seismic performance of electric transmission network under component failures , 2007 .

[23]  Ting-Yu Hsu,et al.  Experimental Study of Isolated Building under Triaxial Ground Excitations , 2000 .

[24]  M.Q. Feng,et al.  Earthquake simulator testing of base-isolated power transformers , 2006, IEEE Transactions on Power Delivery.

[25]  Gregory L. Fenves,et al.  Object-oriented finite element programming: frameworks for analysis, algorithms and parallel computing , 1997 .

[26]  Thalia Anagnos,et al.  Development of an Electrical Substation Equipment Performance Database for Evaluation of Equipment Fragilities , 2002 .