Real-time implementation of grey fuzzy terminal sliding mode control for PWM DC-AC converters

Classical terminal sliding mode control (TSMC) has finite system state convergence time and is insensitive to disturbances and uncertainties within expected limits. However, TSMC may chatter when uncertainty values are overestimated or may exhibit a steady-state error when uncertainty values are underestimated. An improved TSMC is proposed by the use of a mathematically simple and computationally fast grey prediction (GP) methodology, which is then fine-tuned by the use of fuzzy control methodology for PWM DC–AC converters. First, GP methodology is employed to deal with classical TSMC chattering and steady-state error problems. Fuzzy control is then used to tune the GP forecasting value for improved rise time and overshoot characteristics. The system is evaluated by simulation and also by real experiment. Both evaluation methods confirm that the proposed controller achieves low total harmonic distortion under non-linear loading conditions and fast dynamic response under transient loading conditions. Because the proposed grey-fuzzy TSMC methodology is simpler to implement than prior methods and offers more efficient computation, it will be of interest to designers of related control systems.

[1]  Wen-Hui Chen,et al.  Distribution system restoration using the hybrid fuzzy-grey method , 2005 .

[2]  Jean-Pierre Barbot,et al.  Sliding Mode Control In Engineering , 2002 .

[3]  Paolo Mattavelli,et al.  An improved deadbeat control for UPS using disturbance observers , 2005, IEEE Transactions on Industrial Electronics.

[4]  Francesc Guinjoan,et al.  Sliding-mode control design of a boost-buck switching converter for AC signal generation , 2004, IEEE Transactions on Circuits and Systems I: Regular Papers.

[5]  Jian-Shiang Chen,et al.  UPS inverter design using discrete-time sliding-mode control scheme , 2002, IEEE Trans. Ind. Electron..

[6]  H. K. Chiang,et al.  Integral variable structure controller with grey prediction for synchronous reluctance motor drive , 2004 .

[7]  Yong Kang,et al.  Direct repetitive control of SPWM inverter for UPS purpose , 2003 .

[8]  E. Gubia,et al.  Boost DC-AC inverter: a new control strategy , 2005, IEEE Transactions on Power Electronics.

[9]  H.-k. Chiang,et al.  Integral variable-structure grey control for magnetic levitation system , 2006 .

[10]  Bin Wang,et al.  Finite-time tracking controller design for nonholonomic systems with extended chained form , 2005, IEEE Transactions on Circuits and Systems II: Express Briefs.

[11]  Keliang Zhou,et al.  Zero-phase odd-harmonic repetitive controller for a single-phase PWM inverter , 2006, IEEE Transactions on Power Electronics.

[12]  J. Deng,et al.  Introduction to Grey system theory , 1989 .

[13]  Daniel Coutinho,et al.  Multiple-Loop H-Infinity Control Design for Uninterruptible Power Supplies , 2007, IEEE Transactions on Industrial Electronics.

[14]  Lotfi A. Zadeh,et al.  Fuzzy Sets , 1996, Inf. Control..

[15]  Y. Kawabata,et al.  Novel vector control system using deadbeat controlled PWM inverter with output LC filter. Part-2. Controller using strictly z-transformed equations , 2004, The 4th International Power Electronics and Motion Control Conference, 2004. IPEMC 2004..