Photodiode Circuits for Retinal Prostheses

Photodiode circuits show promise for the development of high-resolution retinal prostheses. While several of these systems have been constructed and some even implanted in humans, existing descriptions of the complex optoelectronic interaction between light, photodiode, and the electrode/electrolyte load are limited. This study examines this interaction in depth with theoretical calculations and experimental measurements. Actively biased photoconductive and passive photovoltaic circuits are investigated, with the photovoltaic circuits consisting of one or more diodes connected in series, and the photoconductive circuits consisting of a single diode in series with a pulsed bias voltage. Circuit behavior and charge injection levels were markedly different for platinum and sputtered iridium-oxide film (SIROF) electrodes. Photovoltaic circuits were able to deliver 0.038 mC/cm2 (0.75 nC/phase) per photodiode with 50- μm platinum electrodes, and 0.54-mC/cm2 (11 nC/phase) per photodiode with 50-μ m SIROF electrodes driven with 0.5-ms pulses of light at 25 Hz. The same pulses applied to photoconductive circuits with the same electrodes were able to deliver charge injections as high as 0.38 and 7.6 mC/cm2 (7.5 and 150 nC/phase), respectively. We demonstrate photovoltaic stimulation of rabbit retina in-vitro, with 0.5-ms pulses of 905-nm light using peak irradiance of 1 mW/mm2. Based on the experimental data, we derive electrochemical and optical safety limits for pixel density and charge injection in various circuits. While photoconductive circuits offer smaller pixels, photovoltaic systems do not require an external bias voltage. Both classes of circuits show promise for the development of high-resolution optoelectronic retinal prostheses.

[1]  E. Zrenner,et al.  Electrical multisite stimulation of the isolated chicken retina , 2000, Vision Research.

[2]  E. Zrenner,et al.  Subretinal electrical stimulation of the rabbit retina with acutely implanted electrode arrays , 2004, Graefe's Archive for Clinical and Experimental Ophthalmology.

[3]  David H Sliney,et al.  Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[4]  S.F. Cogan In vivo and In vitro Differences in the Charge-injection and Electrochemical Properties of Iridium Oxide Electrodes , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  E. Chichilnisky,et al.  Large-area microelectrode arrays for recording of neural signals , 2004, IEEE Transactions on Nuclear Science.

[6]  E. Chichilnisky,et al.  High-Resolution Electrical Stimulation of Primate Retina for Epiretinal Implant Design , 2008, The Journal of Neuroscience.

[7]  F. James Statistical Methods in Experimental Physics , 1973 .

[8]  X. Beebe,et al.  Charge injection limits of activated iridium oxide electrodes with 0.2 ms pulses in bicarbonate buffered saline (neurological stimulation application) , 1988, IEEE Transactions on Biomedical Engineering.

[9]  Eberhart Zrenner,et al.  The Subretinal Implant: Can Microphotodiode Arrays Replace Degenerated Retinal Photoreceptors to Restore Vision? , 2002, Ophthalmologica.

[10]  E. Chichilnisky,et al.  Electrical stimulation of mammalian retinal ganglion cells with multielectrode arrays. , 2006, Journal of neurophysiology.

[11]  A.M. Litke,et al.  What does the eye tell the brain?: Development of a system for the large scale recording of retinal output activity , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[12]  J. Wyatt,et al.  Minimally Invasive Retinal Prosthesis , 2006, 2006 IEEE International Solid State Circuits Conference - Digest of Technical Papers.

[13]  Liang Zhu,et al.  Influence of laser parameters on selective retinal treatment using single-phase heat transfer analyses. , 2007, Medical physics.

[14]  Daniel Palanker,et al.  Design of a high-resolution optoelectronic retinal prosthesis , 2005, Journal of neural engineering.

[15]  Rajmohan Bhandari,et al.  Neural electrode degradation from continuous electrical stimulation: Comparison of sputtered and activated iridium oxide , 2010, Journal of Neuroscience Methods.

[16]  Joseph F Rizzo,et al.  Comparison of electrically evoked cortical potential thresholds generated with subretinal or suprachoroidal placement of a microelectrode array in the rabbit , 2005, Journal of neural engineering.

[17]  P. Troyk,et al.  The influence of electrolyte composition on the in vitro charge-injection limits of activated iridium oxide (AIROF) stimulation electrodes , 2007, Journal of neural engineering.

[18]  J. Newman Resistance for Flow of Current to a Disk , 1966 .

[19]  K. Hess Advanced Theory of Semiconductor Devices , 1999 .

[20]  W. Liu,et al.  A neuro-stimulus chip with telemetry unit for retinal prosthetic device , 2000, IEEE Journal of Solid-State Circuits.

[21]  Martin Stelzle,et al.  Electrical Properties of Micro-Photodiode Arrays for Use as Artificial Retina Implant , 2001 .

[22]  S. Kelly,et al.  Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode arrays. , 2003, Investigative ophthalmology & visual science.

[23]  Philip R. Troyk,et al.  Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes , 2006, IEEE Transactions on Biomedical Engineering.

[24]  David Tsai,et al.  Direct activation and temporal response properties of rabbit retinal ganglion cells following subretinal stimulation. , 2009, Journal of neurophysiology.

[25]  U. Schnakenberg,et al.  Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation , 2004 .

[26]  Benoît Gérard,et al.  Pattern recognition with the optic nerve visual prosthesis. , 2003, Artificial organs.

[27]  F. Solzbacher,et al.  In vitro comparison of sputtered iridium oxide and platinum-coated neural implantable microelectrode arrays , 2010, Biomedical materials.

[28]  Joseph F Rizzo,et al.  Thresholds for activation of rabbit retinal ganglion cells with an ultrafine, extracellular microelectrode. , 2003, Investigative ophthalmology & visual science.

[29]  Paul J DeMarco,et al.  Stimulation via a subretinally placed prosthetic elicits central activity and induces a trophic effect on visual responses. , 2007, Investigative ophthalmology & visual science.

[30]  Philip R. Troyk,et al.  In Vitro and In Vivo Charge Capacity of AIROF Microelectrodes , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[31]  Joseph F Rizzo,et al.  Thresholds for activation of rabbit retinal ganglion cells with a subretinal electrode. , 2006, Experimental eye research.

[32]  A. Y. Chow,et al.  The artificial silicon retina microchip for the treatment of vision loss from retinitis pigmentosa. , 2004, Archives of ophthalmology.

[33]  S.F. Cogan,et al.  Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[34]  Alfred Stett,et al.  Subretinal electronic chips allow blind patients to read letters and combine them to words , 2010, Proceedings of the Royal Society B: Biological Sciences.

[35]  Daniel Palanker,et al.  High resolution optoelectronic retinal prosthesis , 2009, BiOS.

[36]  P Hunter Peckham,et al.  Electrode fracture rates and occurrences of infection and granuloma associated with percutaneous intramuscular electrodes in upper-limb functional electrical stimulation applications. , 2002, Journal of rehabilitation research and development.

[37]  I. Wickelgren A Vision for the Blind , 2006, Science.

[38]  Gaston H. Gonnet,et al.  On the LambertW function , 1996, Adv. Comput. Math..

[39]  J D Loudin,et al.  Optoelectronic retinal prosthesis: system design and performance , 2007, Journal of neural engineering.

[40]  D Besch,et al.  Extraocular surgery for implantation of an active subretinal visual prosthesis with external connections: feasibility and outcome in seven patients , 2008, British Journal of Ophthalmology.