Pittfalls of MRI measurement of white matter perfusion based on arterial spin labeling

Although arterial spin labeling (ASL) MRI has been successfully applied to measure gray matter (GM) perfusion in vivo, accurate detection of white matter (WM) perfusion has proven difficult. Reported literature values are not consistent with each other or with perfusion measured with other modalities. In this work, the cause of these inconsistencies is investigated. The results suggest that WM perfusion values are substantially affected by the limited image resolution and by signal losses caused by the long transit times in WM, which significantly affect the label. From gadolinium diethylenetriamine pentaacetic acid (Gd‐DTPA) bolus‐tracking experiments (N = 6), it is estimated that the transit time can be several seconds long in deep WM. Furthermore, simulations show that even at a spatial resolution of 7 μl voxel size, contamination by the GM signals can exceed 40% of the actual WM signal. From 10‐min long flow‐sensitive alternating inversion recovery ASL (FAIR‐ASL) measurements at 3T in normal subjects (N = 7), using highly sensitive detectors, it is shown that single‐voxel (7 μl) deep WM perfusion values have an signal‐to‐noise ratio (SNR) less than 1. The poor sensitivity and heterogeneous transit time limit the applicability of ASL for measurement of perfusion in WM. Magn Reson Med 59:788–795, 2008. © 2008 Wiley‐Liss, Inc.

[1]  John A. Detre,et al.  Continuous ASL perfusion fMRI investigation of higher cognition: Quantification of tonic CBF changes during sustained attention and working memory tasks , 2006, NeuroImage.

[2]  O. Yu,et al.  NMR relaxation rates and blood oxygenation level , 1995, Magnetic resonance in medicine.

[3]  J. Detre,et al.  Reduced Transit-Time Sensitivity in Noninvasive Magnetic Resonance Imaging of Human Cerebral Blood Flow , 1996, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[4]  Edward F Jackson,et al.  Input parameter sensitivity analysis and comparison of quantification models for continuous arterial spin labeling , 2005, Magnetic resonance in medicine.

[5]  Masaki Fukunaga,et al.  Optimizing brain tissue contrast with EPI: A simulated annealing approach , 2005, Magnetic resonance in medicine.

[6]  I. Kanno,et al.  Effect of regional tracer delay on CBF in healthy subjects measured with dynamic susceptibility contrast-enhanced MRI: comparison with 15O-PET. , 2005, Magnetic Resonance in Medical Sciences.

[7]  J. Pickard,et al.  Pattern of white matter regional cerebral blood flow and autoregulation in normal pressure hydrocephalus. , 2004, Brain : a journal of neurology.

[8]  B. Drayer,et al.  Xenon Enhanced CT for Analysis of Cerebral Integrity, Perfusion, and Blood Flow , 1978, Stroke.

[9]  Seong-Gi Kim Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping , 1995, Magnetic resonance in medicine.

[10]  J. Detre,et al.  Perfusion functional MRI reveals cerebral blood flow pattern under psychological stress. , 2005, Proceedings of the National Academy of Sciences of the United States of America.

[11]  J. Detre,et al.  Magnetic resonance perfusion imaging in acute ischemic stroke using continuous arterial spin labeling. , 2000, Stroke.

[12]  Donald S. Williams,et al.  Perfusion imaging , 1992, Magnetic resonance in medicine.

[13]  C J Thompson,et al.  Dynamic Positron Emission Tomography for Study of Cerebral Hemodynamics in a Cross Section of the Head Using Positron‐Emitting 68Ga‐EDTA and 77Kr , 1977, Journal of computer assisted tomography.

[14]  M. Reivich,et al.  Measurement of regional cerebral blood flow with antipyrine-14C in awake cats. , 1969, Journal of applied physiology.

[15]  B. Rosen,et al.  Dynamic imaging with lanthanide chelates in normal brain: Contrast due to magnetic susceptibility effects , 1988, Magnetic resonance in medicine.

[16]  O B Paulson,et al.  Quantitation of Regional Cerebral Blood Flow Corrected for Partial Volume Effect Using O-15 Water and PET: II. Normal Values and Gray Matter Blood Flow Response to Visual Activation , 2000, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[17]  M. Raichle,et al.  What is the Correct Value for the Brain-Blood Partition Coefficient for Water? , 1985, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[18]  Peter C M van Zijl,et al.  An account of the discrepancy between MRI and PET cerebral blood flow measures. A high‐field MRI investigation , 2006, NMR in biomedicine.

[19]  Xavier Golay,et al.  Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla , 2004, Magnetic resonance in medicine.

[20]  Iwao Kanno,et al.  Regional distribution of human cerebral vascular mean transit time measured by positron emission tomography , 2003, NeuroImage.

[21]  C. Beaulieu,et al.  Pulsed arterial spin labeling parameter optimization for an elderly population , 2006, Journal of magnetic resonance imaging : JMRI.

[22]  J. H. Duyn,et al.  Multislice Imaging of Quantitative Cerebral Perfusion with Pulsed Arterial Spin-Labeling , 1998, NeuroImage.

[23]  B. Rosen,et al.  Perfusion imaging with NMR contrast agents , 1990, Magnetic resonance in medicine.

[24]  R. Turner,et al.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[25]  R. Meuli,et al.  Brain perfusion in children: evolution with age assessed by quantitative perfusion computed tomography. , 2004, Pediatrics.

[26]  Marek Czosnyka,et al.  Normal Pressure Hydrocephalus and Cerebral Blood Flow: A PET Study of Baseline Values , 2004, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[27]  X. Golay,et al.  Application of regional perfusion imaging to extra-intracranial bypass surgery and severe stenoses. , 2005, Journal of neuroradiology. Journal de neuroradiologie.

[28]  Renxin Chu,et al.  Scalable multichannel MRI data acquisition system , 2004, Magnetic resonance in medicine.

[29]  P. Boesiger,et al.  SENSE: Sensitivity encoding for fast MRI , 1999, Magnetic resonance in medicine.

[30]  C. Starmer,et al.  Indicator Transit Time Considered as a Gamma Variate , 1964, Circulation research.

[31]  H. Rinneberg,et al.  Human cardiac imaging at 3 T using phased array coils , 2000, Magnetic resonance in medicine.

[32]  Hans H Schild,et al.  Three-dimensional dynamic susceptibility-weighted perfusion MR imaging at 3.0 T: feasibility and contrast agent dose. , 2005, Radiology.

[33]  D. S. Williams,et al.  Magnetic resonance imaging of perfusion using spin inversion of arterial water. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[34]  J W Belliveau,et al.  Functional cerebral imaging by susceptibility‐contrast NMR , 1990, Magnetic resonance in medicine.

[35]  M. Bronskill,et al.  T1, T2 relaxation and magnetization transfer in tissue at 3T , 2005, Magnetic resonance in medicine.

[36]  Renxin Chu,et al.  Magnetic Resonance in Medicine 51:22–26 (2004) Signal-to-Noise Ratio and Parallel Imaging Performance of a 16-Channel Receive-Only Brain Coil Array at , 2022 .