Performance analysis of a multi-functional Heat pump system in heating mode

Abstract A multi-functional heat-pump system is proposed to efficiently utilize the gray water as heat source and sink for heating and cooling of residential buildings, respectively. Heat is reclaimed from the plate heat exchanger installed at the outlet of the compressor to provide sufficient hot water for residential use. To study the performance of this innovative system, laboratory testing is performed with a prototype consisting of an outdoor heat pump, an indoor air handler, a gray water tank and a hot water tank. This system is set in two environmental chambers that they represent: the outdoor and indoor environments, respectively. In this paper, the investigation of the system is mainly focused on the heating performance. The system is designed to allow four combinations of two heat sources that they are a water-source evaporator and an air-source evaporator. The four combinations consist of air source only, water source only, air source and water source in parallel and air source and water source in series, in the refrigerant cycle. Performance of the four combinations of heat sources is experimentally investigated at a typical indoor air temperature of 21.1 °C and various outdoor air temperatures at 1.1, 8.3, and 15.6 °C. The results show that the heat source combinations influence the heating capacity and coefficient of performance (COP) of the system. Also, the system performance and the optimal heat source combination depend on the outdoor temperature. As outdoor temperature decreases, the variation of system performance among different combinations becomes small. The system performance in modes of space heating and space heating plus hot water supply are compared and analyzed. The COP of the system in the space heating plus hot water supply mode increases in all heat source combinations, compared with that in space heating only mode. The performance of the system for heating hot water from 30 °C to 48.9 °C is also studied. This proposed system can provide significant energy savings in space heating and hot water supply. The optimal source combination is critical in pursuing the maximum energy savings.

[1]  Ruzhu Wang,et al.  Performance of a multi-functional direct-expansion solar assisted heat pump system , 2006 .

[2]  R. Hendron Building America Research Benchmark Definition , 2008 .

[3]  Lu Aye,et al.  Natural working fluids for solar-boosted heat pumps , 2003 .

[4]  Ruzhu Wang,et al.  Experimental performance analysis on a direct-expansion solar-assisted heat pump water heater , 2007 .

[5]  M. Eastment,et al.  Development of an Energy Savings Benchmark for All Residential End-Uses: Preprint , 2004 .

[6]  Tin-Tai Chow,et al.  Performance of multi-functional domestic heat-pump system , 2005 .

[7]  Onder Ozgener,et al.  A parametrical study on the energetic and exergetic assessment of a solar-assisted vertical ground-source heat pump system used for heating a greenhouse , 2007 .

[8]  Ruzhu Wang,et al.  Study on a direct‐expansion solar‐assisted heat pump water heating system , 2003 .

[9]  Arif Hepbasli,et al.  Exergetic modeling and assessment of solar assisted domestic hot water tank integrated ground-source heat pump systems for residences , 2007 .

[10]  M.N.A. Hawlader,et al.  Solar-assisted heat-pump dryer and water heater , 2003 .

[11]  S. Chaturvedi,et al.  Thermal performance of a variable capacity direct expansion solar-assisted heat pump , 1998 .

[12]  Onder Ozgener,et al.  Modeling and performance evaluation of ground source (geothermal) heat pump systems , 2007 .

[13]  Siu-Kit Lau,et al.  Feasibility study of a localized residential grey water energy-recovery system , 2012 .

[14]  P. Mayer Residential End Uses of Water , 1999 .

[15]  Arif Hepbasli,et al.  A review of heat pump water heating systems , 2009 .

[16]  Onder Ozgener,et al.  Experimental performance analysis of a solar assisted ground-source heat pump greenhouse heating system , 2005 .

[17]  Arif Hepbasli,et al.  Exergetic assessment of direct-expansion solar-assisted heat pump systems: Review and modeling , 2008 .

[18]  Sadasuke Ito,et al.  Studies of a heat pump using water and air heat sources in parallel , 2000 .

[19]  Robert Hendron,et al.  Building America Research Benchmark Definition: Updated December 2009 , 2008 .

[20]  S. Pierucci,et al.  Applied Thermal Engineering , 2008 .

[21]  M. Boddy,et al.  Department of Energy Energy Efficiency and Renewable Energy Industrial Technologies Program Executive Summary , 2004 .

[22]  Jong-Ho Yoon,et al.  A study on the design and analysis of a heat pump heating system using wastewater as a heat source , 2005 .

[23]  Bin-Juine Huang,et al.  Heat-pipe enhanced solar-assisted heat pump water heater , 2005 .

[24]  A. Hepbasli,et al.  Performance analysis of a solar-assisted ground-source heat pump system for greenhouse heating: an experimental study , 2005 .

[25]  Meng Hu,et al.  APPLICATION OF SHREDDED-TIRE BIOFILTER AND MEMBRANE BIOREACTOR FOR GREYWATER RECLAMATION , 2011 .

[26]  Tin-Tai Chow,et al.  Domestic air-conditioner and integrated water heater for subtropical climate , 2003 .