Endovascular treatment of experimental wide neck aneurysms: comparison of results using coils or cyanoacrylate with the assistance of an aneurysm neck bridge device.

BACKGROUND AND PURPOSE Endovascular treatment of wide neck aneurysms often results in incomplete occlusion or aneurysm recurrence. The two goals of the present study were to compare results of coil embolization with or without the assistance of an aneurysm neck bridge device (ANBD) and to explore the use of this instrument to control cyanoacrylate embolization. METHODS Wide necked bifurcation aneurysms were constructed in 28 dogs. Coil embolization of the aneurysms was performed 2 to 4 weeks later, with (n = 11) or without (n = 10) ANBD assistance. In seven other animals, embolization was performed with cyanoacrylate, injected under the protection of ANBDs. Angiographic results were compared immediately after and at 3 and 12 weeks. Neointima formation at the neck was also compared between groups at 12 weeks. RESULTS Initial angiographic results and recurrences at 12 weeks were not significantly different in aneurysms coiled with or without ANBDs. Neointimal scores were also similar. The use of one ANBD at the neck was not sufficient to safely deliver cyanoacrylate into aneurysms. Cyanoacrylate embolization led to improved angiographic results (P =.05) and to better neointimal sealing of the neck of the aneurysms at 12 weeks (P =.004). CONCLUSION ANBDs did not prevent recanalization and recurrences after coil embolization of wide neck aneurysms in this animal study. ANBD-assisted cyanoacrylate embolization was unsafe but could decrease recurrences at 12 weeks.

[1]  JeanRaymond,et al.  In Situ Beta Radiation to Prevent Recanalization After Coil Embolization of Cerebral Aneurysms , 2002 .

[2]  D. Roy,et al.  Cyanoacrylate embolization of experimental aneurysms. , 2002, AJNR. American journal of neuroradiology.

[3]  S. Cha Relative recirculation: what does it mean? , 2002, AJNR. American journal of neuroradiology.

[4]  D. Roy,et al.  Neck-bridge device for endovascular treatment of wide-neck bifurcation aneurysms: initial experience. , 2001, Radiology.

[5]  Daniel Roy,et al.  Endovascular Treatment of Unruptured Aneurysms , 2001, Stroke.

[6]  R. Virmani,et al.  Evaluation of the TriSpan Neck Bridge Device for the Treatment of Wide-Necked Aneurysms: An Experimental Study in Canines , 2001, Stroke.

[7]  J. Dion,et al.  Use of three-dimensional Guglielmi detachable coils in the treatment of wide-necked cerebral aneurysms. , 2000, AJNR. American journal of neuroradiology.

[8]  JeanRaymond,et al.  Growth Factors Stimulate Neointimal Cells In Vitro and Increase the Thickness of the Neointima Formed at the Neck of Porcine Aneurysms Treated by Embolization , 2000 .

[9]  F Viñuela,et al.  Ballonn-assisted Guglielmi detachable coiling of wide-necked aneurysma: Part II--clinical results. , 1999, Neurosurgery.

[10]  D. Roy,et al.  Fibrinogen and vascular smooth muscle cell grafts promote healing of experimental aneurysms treated by embolization. , 1999, Stroke.

[11]  G. Leclerc,et al.  Healing of experimental aneurysms. II: Platelet extracts can increase the thickness of the neointima at the neck of treated aneurysms. , 1999, Journal of neuroradiology. Journal de neuroradiologie.

[12]  Y. Aydın,et al.  Selection of cerebral aneurysms for treatment using Guglielmi detachable coils: the preliminary University of Illinois at Chicago experience. , 1999, Neurosurgery.

[13]  D. Pelz,et al.  Thromboembolic events associated with the treatment of cerebral aneurysms with Guglielmi detachable coils. , 1998, AJNR. American journal of neuroradiology.

[14]  M. Iwaki,et al.  Ion implantation and protein coating of detachable coils for endovascular treatment of cerebral aneurysms: concepts and preliminary results in swine models. , 1997, Neurosurgery.

[15]  C. Cognard,et al.  The “Remodelling Technique” in the Treatment of Wide Neck Intracranial Aneurysms , 1997, Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences.

[16]  G. Duckwiler,et al.  Endovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results. , 1994, AJNR. American journal of neuroradiology.