Additive noise models for photoacoustic spatial coherence theory

Directly displaying the spatial coherence of photoacoustic signals (i.e., coherencebased photoacoustic imaging) remarkably improves image contrast, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and imaging depthwhen compared to conventional amplitude-based reconstruction techniques (e.g., backprojection, delay-and-sum beamforming, and Fourier-based reconstruction). We recently developed photoacoustic-specific theory to describe the spatial coherence process as a function of the element spacing on a receive acoustic aperture to enable photoacoustic image optimization without requiring experiments. However, this theory lacked noise models, which contributed to significant departures in coherence measurements when compared to experimental data, particularly at higher values of element separation. In this paper, we develop and implement two models based on experimental observations of noise in photoacoustic spatial coherence measurements to improve our existing spatial coherence theory. These models were derived to describe the effects of incident fluence variations, low-energy light sources (e.g., pulsed laser diodes and light-emitting diodes), averaging multiple signals from low-energy light sources, and imaging with light sources that are > 5mm from photoacoustic targets. Results qualitatively match experimental coherence functions and provide similar contrast, SNR, and CNR to experimental SLSC images. In particular, the added noise affects image quality metrics by introducing large variations in target contrast and significantly reducing target CNR and SNR when compared to minimal-noise cases. These results provide insight into additional requirements for optimization of coherence-based photoacoustic image quality. © 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

[1]  Gregg E Trahey,et al.  Equivalence of time and aperture domain additive noise in ultrasound coherence. , 2015, The Journal of the Acoustical Society of America.

[2]  Jesse V. Jokerst,et al.  The characterization of an economic and portable LED-based photoacoustic imaging system to facilitate molecular imaging , 2017, Photoacoustics.

[3]  Muyinatu A. Lediju Bell,et al.  Coherence-based photoacoustic imaging of brachytherapy seeds implanted in a canine prostate , 2014, Medical Imaging.

[4]  Muyinatu A. Lediju Bell,et al.  Photoacoustic-based approach to surgical guidance performed with and without a da Vinci robot , 2017, Journal of Biomedical Optics.

[5]  Xu Xiao Photoacoustic imaging in biomedicine , 2008 .

[6]  W Steenbergen,et al.  Handheld probe integrating laser diode and ultrasound transducer array for ultrasound/photoacoustic dual modality imaging. , 2014, Optics express.

[7]  Michael C. Kolios,et al.  Improving the quality of photoacoustic images using the short-lag spatial coherence imaging technique , 2013, Photonics West - Biomedical Optics.

[8]  Pai-Chi Li,et al.  SNR-dependent coherence-based adaptive imaging for high-frame-rate ultrasonic and photoacoustic imaging , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[9]  Suhyun Park,et al.  Adaptive beamforming for photoacoustic imaging. , 2008, Optics letters.

[10]  Muyinatu A. Lediju Bell,et al.  Improved contrast in laser-diode-based photoacoustic images with short-lag spatial coherence beamforming , 2014, 2014 IEEE International Ultrasonics Symposium.

[11]  Lihong V. Wang,et al.  Photoacoustic imaging of the microvasculature with a high-frequency ultrasound array transducer. , 2007, Journal of biomedical optics.

[12]  G. E. Trahey,et al.  Short-lag spatial coherence of backscattered echoes: imaging characteristics , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  Paul Kumar Upputuri,et al.  Performance characterization of low-cost, high-speed, portable pulsed laser diode photoacoustic tomography (PLD-PAT) system. , 2015, Biomedical optics express.

[14]  P. Beard Biomedical photoacoustic imaging , 2011, Interface Focus.

[15]  Jin U. Kang,et al.  In vivo visualization of prostate brachytherapy seeds with photoacoustic imaging , 2014, Journal of biomedical optics.

[16]  Erwin J. Alles,et al.  Photoacoustic clutter reduction using short-lag spatial coherence weighted imaging , 2014, 2014 IEEE International Ultrasonics Symposium.

[17]  M. L. Li,et al.  Optoacoustic imaging with synthetic aperture focusing and coherence weighting. , 2004, Optics letters.

[18]  Michelle Graham,et al.  Theoretical application of short-lag spatial coherence to photoacoustic imaging , 2017, 2017 IEEE International Ultrasonics Symposium (IUS).

[19]  Anastasia K. Ostrowski,et al.  Localization of Transcranial Targets for Photoacoustic-Guided Endonasal Surgeries , 2015, Photoacoustics.

[20]  Roy G. M. Kolkman,et al.  In vivo photoacoustic imaging of blood vessels with a pulsed laser diode , 2006, Lasers in Medical Science.

[21]  Adrien E. Desjardins,et al.  Human placental vasculature imaging using an LED-based photoacoustic/ultrasound imaging system , 2018, BiOS.

[22]  Xiaoyu Guo,et al.  Transurethral light delivery for prostate photoacoustic imaging , 2015, Journal of biomedical optics.

[23]  Adrien E. Desjardins,et al.  Handheld Real-Time LED-Based Photoacoustic and Ultrasound Imaging System for Accurate Visualization of Clinical Metal Needles and Superficial Vasculature to Guide Minimally Invasive Procedures , 2018, Sensors.

[24]  Paul C Beard,et al.  Pulsed near-infrared laser diode excitation system for biomedical photoacoustic imaging. , 2006, Optics letters.

[25]  Emad M Boctor,et al.  Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds. , 2013, Biomedical optics express.