Computer simulation of CT mammography using a flat-panel imager

Software has been developed to simulate a cone-beam CT mammography imaging system that consists of an x-ray tube and a flat-panel detector that rotate simultaneously around the pendant breast. The simulation uses an analytical expression or ray-tracing to generate projection sets of breast phantoms at 1 keV intervals dictated by the input x-ray energy spectra. The x-ray focal spot was modeled as having a Gaussian distribution. The detector was modeled as an amorphous silicon (aSi:H) flat-panel imager that uses a structured CsI scintillator. Noise propagation through the detector was simulated by modeling statistical variations of the projection images at each energy interval as a scaled Poisson process. Scintillator blurring was simulated by using an empirically determined modulation transfer function. After introducing noise and detector blur, projection sets simulated at each energy were then combined and reconstructed using Feldkamp's cone-beam reconstruction algorithm. Using this framework, the effects of a number of acquisition and reconstruction parameters can be investigated. Some examples are shown including the impact of the kVp setting and the number of projection angles on the reconstructed image.

[1]  R. Siddon Fast calculation of the exact radiological path for a three-dimensional CT array. , 1985, Medical physics.

[2]  J. Boone,et al.  Dedicated breast CT: radiation dose and image quality evaluation. , 2001, Radiology.

[3]  J. Boone,et al.  Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment. , 1999, Radiology.

[4]  G. Mageras,et al.  A measurement of the light yield of common inorganic scintillators , 1988 .

[5]  Aldo Badano,et al.  Depth-dependent phosphor blur in indirect x-ray imaging sensors , 2002, SPIE Medical Imaging.

[6]  C Abbey,et al.  Statistical texture synthesis of mammographic images with super-blob lumpy backgrounds. , 1999, Optics express.

[7]  Victor Perez-Mendez,et al.  Amorphous silicon pixel layers with cesium iodide converters for medical radiography , 1994 .

[8]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[9]  J. Boone,et al.  An accurate method for computer-generating tungsten anode x-ray spectra from 30 to 140 kV. , 1997, Medical physics.

[10]  Andrew D. A. Maidment,et al.  Mammogram synthesis using a 3D simulation. I. Breast tissue model and image acquisition simulation. , 2002, Medical physics.

[11]  J Yorkston,et al.  Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology. , 1997, Medical physics.

[12]  P. C. Johns,et al.  X-ray characterisation of normal and neoplastic breast tissues. , 1987, Physics in medicine and biology.

[13]  Biao Chen,et al.  Cone-beam volume CT breast imaging: feasibility study. , 2002, Medical physics.

[14]  Aaas News,et al.  Book Reviews , 1893, Buffalo Medical and Surgical Journal.

[15]  Victor Perez-Mendez,et al.  Amorphous silicon pixel radiation detectors and associated thin film transistor electronics readout , 1992 .

[16]  Ruola Ning,et al.  Flat-panel detector-based cone-beam volume CT breast imaging: preliminary phantom study , 2001, SPIE Medical Imaging.