A Novel Fault Diagnosis System on Polymer Insulation of Power Transformers Based on 3-stage GA–SA–SVM OFC Selection and ABC–SVM Classifier
暂无分享,去创建一个
[1] A. O. Akumu,et al. Comparison of IEC 60599 gas ratios and an integrated fuzzy-evidential reasoning approach in fault identification using dissolved gas analysis , 2016, 2016 51st International Universities Power Engineering Conference (UPEC).
[2] Hanbo Zheng,et al. Comparative Investigation on the Performance of Modified System Poles and Traditional System Poles Obtained from PDC Data for Diagnosing the Ageing Condition of Transformer Polymer Insulation Materials , 2018, Polymers.
[3] Wolfgang Borutzky,et al. Bond Graph Modelling of Engineering Systems , 2011 .
[4] Wagner Endo,et al. Development of an Application Based on the Duval Triangle Method , 2017, IEEE Latin America Transactions.
[5] H. C. Verma,et al. A method to estimate activation energy of power transformer insulation using time domain spectroscopy data , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.
[6] Gerard Ledwich,et al. A novel fuzzy logic approach to transformer fault diagnosis , 2000 .
[7] V. Miranda,et al. Improving the IEC table for transformer failure diagnosis with knowledge extraction from neural networks , 2005, IEEE Transactions on Power Delivery.
[8] Yilu Liu,et al. Wavelet Networks in Power Transformers Diagnosis Using Dissolved Gas Analysis , 2009, IEEE Transactions on Power Delivery.
[9] Sung-wook Kim,et al. New methods of DGA diagnosis using IEC TC 10 and related databases Part 1: application of gas-ratio combinations , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.
[10] P. Mirowski,et al. Statistical Machine Learning and Dissolved Gas Analysis: A Review , 2012, IEEE Transactions on Power Delivery.
[11] P. Purkait,et al. An attempt to correlate time & frequency domain polarisation measurements for the insulation diagnosis of power transformer , 2004, IEEE Power Engineering Society General Meeting, 2004..
[12] A. Abu-Siada,et al. A review of dissolved gas analysis measurement and interpretation techniques , 2014, IEEE Electrical Insulation Magazine.
[13] Gehao Sheng,et al. Dissolved gas analysis of insulating oil for power transformer fault diagnosis with deep belief network , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.
[14] Frederico G. Guimarães,et al. A cognitive system for fault prognosis in power transformers , 2015 .
[15] W.H. Tang,et al. A Probabilistic Classifier for Transformer Dissolved Gas Analysis With a Particle Swarm Optimizer , 2008, IEEE Transactions on Power Delivery.
[16] J. Unsworth,et al. Degradation of electrical insulating paper monitored with high performance liquid chromatography , 1990 .
[17] Hanbo Zheng,et al. An anomaly identification model for wind turbine state parameters , 2018, Journal of Cleaner Production.
[18] Chao-Ming Huang,et al. A Review of Dissolved Gas Analysis in Power Transformers , 2012 .
[19] Ruijin Liao,et al. Grey Relational Analysis for Insulation Condition Assessment of Power Transformers Based Upon Conventional Dielectric Response Measurement , 2017 .
[20] Y. C. Huang,et al. A New Data Mining Approach to Dissolved Gas Analysis of Oil-Insulated Power Apparatus , 2002, IEEE Power Engineering Review.
[21] H. Wilhelm,et al. Dissolved gas analysis (DGA) of natural ester insulating fluids with different chemical compositions , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.
[22] Yi Sun,et al. An Approach to Improve the Performance of Simulated Annealing Algorithm Utilizing the Variable Universe Adaptive Fuzzy Logic System , 2017, IEEE Access.
[23] Michel Duval,et al. Interpretation of gas-in-oil analysis using new IEC publication 60599 and IEC TC 10 databases , 2001 .
[24] Jawad Faiz,et al. Dissolved gas analysis evaluation in electric power transformers using conventional methods a review , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.
[25] Michel Duval,et al. Significance and detection of very low degree of polymerization of paper in transformers , 2017, IEEE Electrical Insulation Magazine.
[26] Jeffrey P. Walker,et al. Analysis of Data Acquisition Time on Soil Moisture Retrieval From Multiangle L-Band Observations , 2018, IEEE Transactions on Geoscience and Remote Sensing.
[27] Bin Chen,et al. Carbon emissions and their drivers for a typical urban economy from multiple perspectives: A case analysis for Beijing city , 2018, Applied Energy.
[28] Ruijin Liao,et al. Study on Quantitative Correlations between the Ageing Condition of Transformer Cellulose Insulation and the Large Time Constant Obtained from the Extended Debye Model , 2017 .
[29] M. Teguar,et al. Application of SVM and KNN to Duval Pentagon 1 for transformer oil diagnosis , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.
[30] C. Bengtsson,et al. Status and trends in transformer monitoring , 1996 .
[31] A. O. Akumu,et al. A new fault diagnostic technique in oil-filled electrical equipment; the dual of Duval triangle , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.
[32] M. A. Djeziri,et al. Data driven and model based fault prognosis applied to a mechatronic system , 2013, 4th International Conference on Power Engineering, Energy and Electrical Drives.
[33] Jing Zhou,et al. A Fault Detection and Health Monitoring Scheme for Ship Propulsion Systems Using SVM Technique , 2018, IEEE Access.
[34] R. Rogers. IEEE and IEC Codes to Interpret Incipient Faults in Transformers, Using Gas in Oil Analysis , 1978, IEEE Transactions on Electrical Insulation.
[35] Ming-Ta Yang,et al. Intelligent fault types diagnostic system for dissolved gas analysis of oil-immersed power transformer , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.
[36] Dervis Karaboga,et al. A survey: algorithms simulating bee swarm intelligence , 2009, Artificial Intelligence Review.
[37] Hanbo Zheng,et al. A novel model based on wavelet LS-SVM integrated improved PSO algorithm for forecasting of dissolved gas contents in power transformers , 2018 .
[38] Ruijin Liao,et al. A New Support Vector Machine Model Based on Improved Imperialist Competitive Algorithm for Fault Diagnosis of Oil-immersed Transformers , 2017 .
[39] Hongliang Li,et al. General Regression Neural Network and Artificial-Bee-Colony Based General Regression Neural Network Approaches to the Number of End-of-Life Vehicles in China , 2018, IEEE Access.
[40] S Singh,et al. Dissolved gas analysis technique for incipient fault diagnosis in power transformers: A bibliographic survey , 2010, IEEE Electrical Insulation Magazine.