A Novel Fault Diagnosis System on Polymer Insulation of Power Transformers Based on 3-stage GA–SA–SVM OFC Selection and ABC–SVM Classifier

Dissolved gas analysis (DGA) has been widely used in various scenarios of power transformers’ online monitoring and diagnoses. However, the diagnostic accuracy of traditional DGA methods still leaves much room for improvement. In this context, numerous new DGA diagnostic models that combine artificial intelligence with traditional methods have emerged. In this paper, a new DGA artificial intelligent diagnostic system is proposed. There are two modules that make up the diagnosis system. The two modules are the optimal feature combination (OFC) selection module based on 3-stage GA–SA–SVM and the ABC–SVM fault diagnosis module. The diagnosis system has been completely realized and embodied in its outstanding performances in diagnostic accuracy, reliability, and efficiency. Comparing the result with other artificial intelligence diagnostic methods, the new diagnostic system proposed in this paper performed superiorly.

[1]  A. O. Akumu,et al.  Comparison of IEC 60599 gas ratios and an integrated fuzzy-evidential reasoning approach in fault identification using dissolved gas analysis , 2016, 2016 51st International Universities Power Engineering Conference (UPEC).

[2]  Hanbo Zheng,et al.  Comparative Investigation on the Performance of Modified System Poles and Traditional System Poles Obtained from PDC Data for Diagnosing the Ageing Condition of Transformer Polymer Insulation Materials , 2018, Polymers.

[3]  Wolfgang Borutzky,et al.  Bond Graph Modelling of Engineering Systems , 2011 .

[4]  Wagner Endo,et al.  Development of an Application Based on the Duval Triangle Method , 2017, IEEE Latin America Transactions.

[5]  H. C. Verma,et al.  A method to estimate activation energy of power transformer insulation using time domain spectroscopy data , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.

[6]  Gerard Ledwich,et al.  A novel fuzzy logic approach to transformer fault diagnosis , 2000 .

[7]  V. Miranda,et al.  Improving the IEC table for transformer failure diagnosis with knowledge extraction from neural networks , 2005, IEEE Transactions on Power Delivery.

[8]  Yilu Liu,et al.  Wavelet Networks in Power Transformers Diagnosis Using Dissolved Gas Analysis , 2009, IEEE Transactions on Power Delivery.

[9]  Sung-wook Kim,et al.  New methods of DGA diagnosis using IEC TC 10 and related databases Part 1: application of gas-ratio combinations , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[10]  P. Mirowski,et al.  Statistical Machine Learning and Dissolved Gas Analysis: A Review , 2012, IEEE Transactions on Power Delivery.

[11]  P. Purkait,et al.  An attempt to correlate time & frequency domain polarisation measurements for the insulation diagnosis of power transformer , 2004, IEEE Power Engineering Society General Meeting, 2004..

[12]  A. Abu-Siada,et al.  A review of dissolved gas analysis measurement and interpretation techniques , 2014, IEEE Electrical Insulation Magazine.

[13]  Gehao Sheng,et al.  Dissolved gas analysis of insulating oil for power transformer fault diagnosis with deep belief network , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  Frederico G. Guimarães,et al.  A cognitive system for fault prognosis in power transformers , 2015 .

[15]  W.H. Tang,et al.  A Probabilistic Classifier for Transformer Dissolved Gas Analysis With a Particle Swarm Optimizer , 2008, IEEE Transactions on Power Delivery.

[16]  J. Unsworth,et al.  Degradation of electrical insulating paper monitored with high performance liquid chromatography , 1990 .

[17]  Hanbo Zheng,et al.  An anomaly identification model for wind turbine state parameters , 2018, Journal of Cleaner Production.

[18]  Chao-Ming Huang,et al.  A Review of Dissolved Gas Analysis in Power Transformers , 2012 .

[19]  Ruijin Liao,et al.  Grey Relational Analysis for Insulation Condition Assessment of Power Transformers Based Upon Conventional Dielectric Response Measurement , 2017 .

[20]  Y. C. Huang,et al.  A New Data Mining Approach to Dissolved Gas Analysis of Oil-Insulated Power Apparatus , 2002, IEEE Power Engineering Review.

[21]  H. Wilhelm,et al.  Dissolved gas analysis (DGA) of natural ester insulating fluids with different chemical compositions , 2014, IEEE Transactions on Dielectrics and Electrical Insulation.

[22]  Yi Sun,et al.  An Approach to Improve the Performance of Simulated Annealing Algorithm Utilizing the Variable Universe Adaptive Fuzzy Logic System , 2017, IEEE Access.

[23]  Michel Duval,et al.  Interpretation of gas-in-oil analysis using new IEC publication 60599 and IEC TC 10 databases , 2001 .

[24]  Jawad Faiz,et al.  Dissolved gas analysis evaluation in electric power transformers using conventional methods a review , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.

[25]  Michel Duval,et al.  Significance and detection of very low degree of polymerization of paper in transformers , 2017, IEEE Electrical Insulation Magazine.

[26]  Jeffrey P. Walker,et al.  Analysis of Data Acquisition Time on Soil Moisture Retrieval From Multiangle L-Band Observations , 2018, IEEE Transactions on Geoscience and Remote Sensing.

[27]  Bin Chen,et al.  Carbon emissions and their drivers for a typical urban economy from multiple perspectives: A case analysis for Beijing city , 2018, Applied Energy.

[28]  Ruijin Liao,et al.  Study on Quantitative Correlations between the Ageing Condition of Transformer Cellulose Insulation and the Large Time Constant Obtained from the Extended Debye Model , 2017 .

[29]  M. Teguar,et al.  Application of SVM and KNN to Duval Pentagon 1 for transformer oil diagnosis , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.

[30]  C. Bengtsson,et al.  Status and trends in transformer monitoring , 1996 .

[31]  A. O. Akumu,et al.  A new fault diagnostic technique in oil-filled electrical equipment; the dual of Duval triangle , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[32]  M. A. Djeziri,et al.  Data driven and model based fault prognosis applied to a mechatronic system , 2013, 4th International Conference on Power Engineering, Energy and Electrical Drives.

[33]  Jing Zhou,et al.  A Fault Detection and Health Monitoring Scheme for Ship Propulsion Systems Using SVM Technique , 2018, IEEE Access.

[34]  R. Rogers IEEE and IEC Codes to Interpret Incipient Faults in Transformers, Using Gas in Oil Analysis , 1978, IEEE Transactions on Electrical Insulation.

[35]  Ming-Ta Yang,et al.  Intelligent fault types diagnostic system for dissolved gas analysis of oil-immersed power transformer , 2013, IEEE Transactions on Dielectrics and Electrical Insulation.

[36]  Dervis Karaboga,et al.  A survey: algorithms simulating bee swarm intelligence , 2009, Artificial Intelligence Review.

[37]  Hanbo Zheng,et al.  A novel model based on wavelet LS-SVM integrated improved PSO algorithm for forecasting of dissolved gas contents in power transformers , 2018 .

[38]  Ruijin Liao,et al.  A New Support Vector Machine Model Based on Improved Imperialist Competitive Algorithm for Fault Diagnosis of Oil-immersed Transformers , 2017 .

[39]  Hongliang Li,et al.  General Regression Neural Network and Artificial-Bee-Colony Based General Regression Neural Network Approaches to the Number of End-of-Life Vehicles in China , 2018, IEEE Access.

[40]  S Singh,et al.  Dissolved gas analysis technique for incipient fault diagnosis in power transformers: A bibliographic survey , 2010, IEEE Electrical Insulation Magazine.