Development of a palm portable mass spectrometer

A palm portable mass spectrometer (PPMS) has been developed with a weight of 1. 48 kg (3 lb) and a size of 1.54 L (8.2 × 7.7 × 24.5 cm3) that can be operated with an average battery power of 5 W. A miniaturized ion trap has been used as a mass analyzer that consists of four parallel disks with coaxial holes. A rf voltage of 1500 Vp-p at 3.9 MHz has been used for scanning ion mass of up to m/z 300. An ion-getter pump serves for high vacuum of the PPMS. Sample gas was introduced in pulse mode. An embedded microcomputer has been developed for system control. Detection of organic gases diluted in the air has been demonstrated up to 6 ppm for toluene and 22 ppm for dimethyl methylphosphonate (DMMP). Performance results suggest usefulness of the PPMS as a personal mobile device for detection/identification of chemical warfare agents in the field.

[1]  R. Cooks,et al.  Improved detection of low vapor pressure compounds in air by serial combination of single-sided membrane introduction with fiber introduction mass spectrometry (SS-MIMS-FIMS). , 2005, The Analyst.

[2]  R. Cooks,et al.  Miniature mass analyzers , 2000, Journal of mass spectrometry : JMS.

[3]  R. Cooks,et al.  A miniature cylindrical quadrupole ion trap:  simulation and experiment. , 1998, Analytical Chemistry.

[4]  R. Cooks,et al.  A quadrupole ion trap with cylindrical geometry operated in the mass-selective instability mode. , 1998, Analytical chemistry.

[5]  Badman,et al.  Characterization of a serial array of miniature cylindrical ion trap mass analyzers , 1999, Rapid communications in mass spectrometry : RCM.

[6]  Stephen J. Martin,et al.  Acoustic Wave Sensors: Theory, Design and Physico-Chemical Applications , 1996 .

[7]  Qingyu Song,et al.  Handheld rectilinear ion trap mass spectrometer. , 2006, Analytical chemistry.

[8]  R. March,et al.  Quadrupole storage mass spectrometry , 1989 .

[9]  Z. Karpas,et al.  Ion mobility spectrometry , 1993, Breathborne Biomarkers and the Human Volatilome.

[10]  C. Oh,et al.  Characteristics of cylindrical ion trap , 2003 .

[11]  J. Michael Ramsey,et al.  Micro ion trap mass spectrometry , 1999 .

[12]  Alim A. Fatah,et al.  Guide for the Selection of Chemical Agent and Toxic Industrial Material Detection Equipment for Emergency First Responders, Guide 100-04 Vol. I & II | NIST , 2005 .

[13]  R. Cooks,et al.  Quadrupole Ion Traps and Trap Arrays: Geometry, Material, Scale, Performance , 2007, European journal of mass spectrometry.

[14]  H. Hill,et al.  Conventional analytical methods for chemical warfare agents , 2002 .