Liquid chromatography-tandem mass spectrometry method for the simultaneous quantitative determination of the organophosphorus pesticides dimethoate, fenthion, diazinon and chlorpyrifos in human blood.

Simultaneous determination of the organophosphorus pesticides dimethoate, fenthion, diazinon and chlorpyrifos in human blood by HPLC-tandem mass spectrometry was developed and validated. The pesticides were extracted by a simple one-step protein precipitation procedure. Chromatography was performed on a Luna C(18) (30mmx2.0mm, 3microm) column, using a step-gradient at a flow rate of 0.4ml/min. The assay was linear from 0.5 to 100ng/ml (r(2)>0.992, n=24) for all pesticides. The inter- and intra-day accuracy and precision for the method was 96.6-106.1% and <10%, respectively. The lower limit of quantification was 0.5ng/ml. In conclusion, the method described displays analytical performance characteristics that are suitable for the quantification of these pesticides in cases of acute poisoning.

[1]  H. Maurer Current role of liquid chromatography–mass spectrometry in clinical and forensic toxicology , 2007, Analytical and bioanalytical chemistry.

[2]  J. V. Sancho,et al.  Critical review of the application of liquid chromatography/mass spectrometry to the determination of pesticide residues in biological samples , 2005, Analytical and bioanalytical chemistry.

[3]  Dana B Barr,et al.  Analytical methods for biological monitoring of exposure to pesticides: a review. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[4]  P. Marquet,et al.  Current role of LC-MS in therapeutic drug monitoring , 2007, Analytical and bioanalytical chemistry.

[5]  J. V. Sancho,et al.  Direct determination of chlorpyrifos and its main metabolite 3,5, 6-trichloro-2-pyridinol in human serum and urine by coupled-column liquid chromatography/electrospray-tandem mass spectrometry. , 2000, Rapid communications in mass spectrometry : RCM.

[6]  P. Taylor Matrix effects: the Achilles heel of quantitative high-performance liquid chromatography-electrospray-tandem mass spectrometry. , 2005, Clinical biochemistry.

[7]  W. Lambert,et al.  Analysis of fenthion in postmortem samples by HPLC with diode-array detection and GC-MS using solid-phase extraction. , 1998, Journal of analytical toxicology.

[8]  Asa Bradman,et al.  Measurement of dialkyl phosphate metabolites of organophosphorus pesticides in human urine using lyophilization with gas chromatography-tandem mass spectrometry and isotope dilution quantification , 2004, Journal of Exposure Analysis and Environmental Epidemiology.

[9]  E. Ostrea,et al.  Detection of prenatal exposure to several classes of environmental toxicants and their metabolites by gas chromatography-mass spectrometry in maternal and umbilical cord blood. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[10]  N. Buckley,et al.  Influence of pesticide regulation on acute poisoning deaths in Sri Lanka. , 2003, Bulletin of the World Health Organization.

[11]  Vinod P. Shah,et al.  Bioanalytical Method Validation—A Revisit with a Decade of Progress , 2000, Pharmaceutical Research.

[12]  Julian H Barth,et al.  Testosterone measurement by isotope-dilution liquid chromatography-tandem mass spectrometry: validation of a method for routine clinical practice. , 2005, Clinical chemistry.

[13]  N. Jewell,et al.  Association of in Utero Organophosphate Pesticide Exposure and Fetal Growth and Length of Gestation in an Agricultural Population , 2004, Environmental health perspectives.

[14]  Asa Bradman,et al.  Cumulative organophosphate pesticide exposure and risk assessment among pregnant women living in an agricultural community: a case study from the CHAMACOS cohort. , 2003, Environmental health perspectives.

[15]  D. Barr,et al.  Use of biomarkers to indicate exposure of children to organophosphate pesticides: implications for a longitudinal study of children's environmental health. , 2003, Environmental health perspectives.

[16]  W. Niessen,et al.  Matrix effects in quantitative pesticide analysis using liquid chromatography-mass spectrometry. , 2006, Mass spectrometry reviews.

[17]  J. V. Sancho,et al.  Direct determination of alkyl phosphates in human urine by liquid chromatography/electrospray tandem mass spectrometry. , 2002, Rapid communications in mass spectrometry : RCM.

[18]  Nick Buckley,et al.  Pesticide poisoning in the developing world—a minimum pesticides list , 2002, The Lancet.

[19]  D. Warrell,et al.  Multiple-dose activated charcoal in acute self-poisoning: a randomised controlled trial , 2008, The Lancet.

[20]  S. Inoue,et al.  Rapid simultaneous determination for organophosphorus pesticides in human serum by LC-MS. , 2007, Journal of pharmaceutical and biomedical analysis.

[21]  David Gunnell,et al.  The global distribution of fatal pesticide self-poisoning: Systematic review , 2007, BMC public health.

[22]  F. Perera,et al.  Contemporary-use pesticides in personal air samples during pregnancy and blood samples at delivery among urban minority mothers and newborns. , 2002, Environmental health perspectives.

[23]  L. Needham,et al.  Case studies of the use of biomarkers to assess exposures. , 1995, Toxicology letters.

[24]  R. Jackson,et al.  Concentrations of dialkyl phosphate metabolites of organophosphorus pesticides in the U.S. population. , 2003, Environmental health perspectives.

[25]  Andreas K Tsakalof,et al.  Analytical Methods of Biological Monitoring for Exposure to Pesticides: Recent Update , 2007, Therapeutic drug monitoring.

[26]  B. Matuszewski,et al.  Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS. , 2003, Analytical chemistry.

[27]  D. Barr,et al.  A multi-analyte method for the quantification of contemporary pesticides in human serum and plasma using high-resolution mass spectrometry. , 2002, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[28]  A. Rockwood,et al.  Assessing analytical specificity in quantitative analysis using tandem mass spectrometry. , 2005, Clinical biochemistry.

[29]  Dana B Barr,et al.  Quantitation of dialkyl phosphate metabolites of organophosphate pesticides in human urine using GC-MS-MS with isotopic internal standards. , 2002, Journal of analytical toxicology.

[30]  D. Barr,et al.  A liquid chromatography/electrospray ionization–tandem mass spectrometry method for quantification of specific organophosphorus pesticide biomarkers in human urine , 2003, Analytical and bioanalytical chemistry.

[31]  F. Hernández,et al.  Rapid multiresidue determination of organochlorine and organophosphorus compounds in human serum by solid-phase extraction and gas chromatography coupled to tandem mass spectrometry , 2003, Analytical and bioanalytical chemistry.