Monte Carlo simulation in establishing analytical quality requirements for clinical laboratory tests meeting clinical needs.

INTRODUCTION Patient outcomes, such as morbidity and mortality, depend on accurate laboratory test results. Computer simulation of the effects of test performance parameters on outcome measures may represent a valuable approach to defining the quality of assay performance that is needed to provide optimal outcomes. METHODS We carried out computer simulations of patients on intensive insulin treatment to determine the effects of glucose meter imprecision and bias on (1) the frequencies of glucose concentrations >160 mg/dL; (2) the frequencies of hypoglycemia (<60 mg/dL); (3) the mean glucose; and (4) glucose variability. For each patient, starting with a randomly selected initial glucose concentration and individualized responsiveness to insulin, hourly glucose concentrations were simulated to reflect the effects of (1) IV glucose administration, (2) gluconeogenesis, (3) insulin doses as determined using regimens from the University of Washington and Yale University, and (4) errors in glucose measurements by the meter. For each of 45 sets of glucose meter bias and imprecision conditions, 100 patients were simulated, and each patient was followed for 100 h. RESULTS For both insulin regimens: Mean glucose was inversely related to assay bias; glucose variability increased with negative assay bias and assay imprecision; frequencies of glucose concentrations >160 mg/dL increased with negative assay bias and assay imprecision; and frequencies of hypoglycemia increased with positive assay bias and assay imprecision. Nevertheless, each regimen displayed unique sensitivity to variations in meter imprecision and bias. CONCLUSIONS Errors in glucose measurement exert important regimen-dependent effects on glucose control in intensive IV insulin administration. The results of this proof-of-principle study suggest that simulation of the clinical effects of measurement error is an attractive approach for assessment of assay performance requirements.

[1]  Irl B Hirsch,et al.  The rationale and management of hyperglycemia for in-patients with cardiovascular disease: time for change. , 2003, The Journal of clinical endocrinology and metabolism.

[2]  Hubert W Vesper,et al.  Variability among five over-the-counter blood glucose monitors. , 2006, Clinica chimica acta; international journal of clinical chemistry.

[3]  C. Cobelli,et al.  In Silico Preclinical Trials: A Proof of Concept in Closed-Loop Control of Type 1 Diabetes , 2009, Journal of diabetes science and technology.

[4]  Stephane Heritier,et al.  Intensive versus conventional glucose control in critically ill patients. , 2009, The New England journal of medicine.

[5]  Renda Soylemez Wiener,et al.  Ill Adults: A Meta-analysis Benefits and Risks of Tight Glucose Control in Critically , 2010 .

[6]  G. Van den Berghe,et al.  Intensive insulin therapy in the medical ICU. , 2006, The New England journal of medicine.

[7]  C Cobelli,et al.  Quantitative Estimation of Beta Cell Sensitivity to Glucose in the Intact Organism: A Minimal Model of Insulin Kinetics in the Dog , 1980, Diabetes.

[8]  N. Unwin,et al.  Expert Panel on Detection, Evaluation, and Treatment of High Blood Cholesterol in Adults (Adult Treatment Panel III) Detection, Evaluation, and Treatment of High Blood Cholesterol Education Program (NCEP) Expert Panel on Executive Summary of the Third Report of the National , 2009 .

[9]  Fred S Apple,et al.  National Academy of Clinical Biochemistry Laboratory Medicine Practice Guidelines: Clinical characteristics and utilization of biochemical markers in acute coronary syndromes. , 2007, Circulation.

[10]  M Schetz,et al.  Intensive insulin therapy in critically ill patients. , 2001, The New England journal of medicine.

[11]  Irl B Hirsch,et al.  Management of diabetes and hyperglycemia in hospitals. , 2004, Diabetes care.

[12]  P H Petersen Quality specifications based on analysis of effects of performance on clinical decision-making. , 1999, Scandinavian journal of clinical and laboratory investigation.

[13]  J C Boyd,et al.  Quality specifications for glucose meters: assessment by simulation modeling of errors in insulin dose. , 2001, Clinical chemistry.

[14]  James D Dziura,et al.  Implementation of a safe and effective insulin infusion protocol in a medical intensive care unit. , 2004, Diabetes care.

[15]  Deborah J. Cook,et al.  Intensive insulin therapy and mortality among critically ill patients: a meta-analysis including NICE-SUGAR study data , 2009, Canadian Medical Association Journal.

[16]  David B Sacks,et al.  Tight glucose control in the intensive care unit: are glucose meters up to the task? , 2009, Clinical chemistry.

[17]  Greet Van den Berghe,et al.  Intensive insulin therapy for patients in paediatric intensive care: a prospective, randomised controlled study , 2009, The Lancet.

[18]  P. H. Petersen,et al.  Analytical performance characteristics should be judged against objective quality specifications. , 1999, Clinical chemistry.