Investigating the potential impact of energy-efficient measures for retrofitting existing UK hotels to reach the nearly zero energy building (nZEB) standard

The existing non-residential building stock can generally be considered energy-inefficient. The ECUK 2017 report states that the final energy consumption for commercial buildings remained static. The 2010 recast Energy Performance Building Directive (EPBD) has set out a requirement for commercial and residential buildings to be nearly Zero Energy Buildings (nZEBs) by 2020. Despite this, within the UK, a definition does not exist at the national level for commercial nZEBs (new or existing). This paper utilises the EU zebra2020 data tool to set a standard based on the existing UK nZEB commercial building stock. The aim of this paper is to investigate and assess the potential of various energy-efficient measures (EEMs) and their contribution to reducing energy consumption, primary energy consumption (PEC), and CO2 emissions whilst taking into consideration the energy and cost savings of those measures. The analysis is carried out using Thermal Analysis Simulation software (Tas, Edsl). The model validation obtained a performance gap of less than 5%. The results show that it is possible to achieve the nZEB standard for older UK hotel buildings if several measures are implemented and the initial selection of EEMs is carefully investigated. Based on the results, reaching the nZEB target should first take into consideration improving the building fabric and/or building envelope elements to lower the energy demand. Once the energy demand of the building is lowered, the incorporation of a renewable/microgeneration system is essential to meeting the nZEB target.

[1]  Alfonso P. Ramallo-González,et al.  An update of the UK’s test reference year: The implications of a revised climate on building design , 2016 .

[2]  Ergo Pikas,et al.  Cost optimal and nearly zero energy building solutions for office buildings , 2014 .

[3]  Jacqueline Glass,et al.  The modelling gap: Quantifying the discrepancy in the representation of thermal mass in building simulation , 2018 .

[4]  Anastasia Mylona,et al.  Retrofit of a UK residential property to achieve nearly zero energy building standard , 2018 .

[5]  Anastasia Mylona,et al.  Comparison and Evaluation of the Potential Energy, Carbon Emissions, and Financial Impacts from the Incorporation of CHP and CCHP Systems in Existing UK Hotel Buildings , 2018 .

[7]  Roberto Lollini,et al.  Nearly Zero Energy Buildings: An Overview of the Main Construction Features across Europe , 2017 .

[8]  María Uris,et al.  Feasibility assessment of an Organic Rankine Cycle (ORC) cogeneration plant (CHP/CCHP) fueled by biomass for a district network in mainland Spain , 2017 .

[9]  P. Torcellini,et al.  Criteria for Definition of Net Zero Energy Buildings , 2010 .

[10]  Van D Baxter,et al.  Nearly-zero energy buildings , 2016 .

[11]  Per Heiselberg,et al.  A Literature Review of Zero Energy Buildings (ZEB) Definitions , 2009 .

[12]  Julio Bros Williamson,et al.  Historic Scotland Technical Paper 19 - Monitoring thermal upgrades to ten traditional properties , 2013 .

[13]  Karsten Voss,et al.  Net zero energy buildings: A consistent definition framework , 2012 .

[14]  Gerardo Maria Mauro,et al.  Cost-Effective Refurbishment of Italian Historic Buildings , 2017 .

[15]  Chiara Bertolin,et al.  Towards Zero-Emission Refurbishment of Historic Buildings: A Literature Review , 2018 .

[16]  Delia D׳Agostino,et al.  Assessment of the progress towards the establishment of definitions of Nearly Zero Energy Buildings (nZEBs) in European Member States , 2015 .

[17]  Elena Lucchi,et al.  Thermal transmittance of historical stone masonries: A comparison among standard, calculated and measured data , 2017 .

[18]  Björn Berggren,et al.  Net ZEB office in Sweden – A case study, testing the Swedish Net ZEB definition , 2012 .

[19]  S. Tournaki,et al.  Nearly Zero Energy Buildings Application in Mediterranean Hotels , 2013 .

[20]  Jarek Kurnitski Cost optimal and nearly zero-energy buildings (nZEB) , 2013 .

[21]  A. Mylona,et al.  Use of Climate Change Scenarios for Building Simulation: the CIBSE Future Weather Years , 2009 .

[22]  Ali Bahadori-Jahromi,et al.  Impact of standard construction specification on thermal comfort in UK dwellings , 2014 .

[23]  Giuseppina Ciulla,et al.  Redesign of a Rural Building in a Heritage Site in Italy: Towards the Net Zero Energy Target , 2017 .

[24]  Julio Bros Williamson,et al.  Monitoring thermal upgrades to ten traditional properties , 2013 .

[25]  Eike Musall,et al.  From Low-Energy to Net Zero-Energy Buildings: Status and Perspectives , 2011 .

[26]  Paolo Maria Congedo,et al.  Efficient Solutions and Cost-Optimal Analysis for Existing School Buildings , 2016 .

[27]  Eike Musall,et al.  Zero Energy Building A review of definitions and calculation methodologies , 2011 .

[28]  T. Tsoutsos,et al.  Creating paradigms for nearly zero energy hotels in South Europe , 2018 .

[29]  Tadj Oreszczyn,et al.  Solid-wall U-values: heat flux measurements compared with standard assumptions , 2015 .