Dynamic simulation of thermal load and energy efficiency in poultry buildings in the cold zone of China

Abstract Understanding the dynamic heating and cooling load of poultry houses enables more precise environmental housing control; however, there is a lack of efficient tools for evaluating and predicting these loads. The objectives of this study were to develop and validate a toolkit to simulate the hourly building load throughout a year, simulate the base room temperature, and investigate the thermal performance of a commercial poultry house in Beijing. Various infiltrating air volumetric flow rates (0.2, 0.6, 1.0, and 2.0 air changes per hour) and total ventilation rates under three mortality levels (5.0%, 10.0%, and 15.0%) were used for the simulation to compare the annual heating and cooling load (AHL and ACL). The correlations between measured and simulated data were 0.99 for indoor air temperature and 0.90 for relative humidity. Based on the simulation results, the base room temperature was −9.2 to 42.2 °C throughout the year. The recommended temperature was met only 38.80% of the year, indicating that extra energy must be consumed to maintain a suitable temperature all year. Air inlets (windows and doors) were altered to meet Chinese energy efficiency standards, which decreased the maximum AHL and ACL by approximately 11.10% and 4.81%, respectively. When the tightness of envelope construction was adjusted from “loose” to “medium” and from “loose” to “tight”, the maximum AHL decreased by 15.45% and 19.86% and the maximum ACL decreased by 4.45% and 5.72%, respectively. Decreasing the ventilation rate reduced the hourly cooling and heating load from 12.51 to 50.04 KW and 3.75–15.01 KW, respectively, due to different mortality rates when the air temperature difference was 5.0 °C and 20.0 °C. The proposed simulation toolkit is an effective and accurate tool for evaluating and predicting dynamic building loads for poultry houses. Hourly dynamic thermal simulations throughout the year can accurately determine potential problems in housing systems and lead to appropriate energy-saving strategies.

[1]  Sholahudin,et al.  Prediction and Analysis of Building Energy Efficiency Using Artificial Neural Network and Design of Experiments , 2016 .

[2]  Chen Jing-kun,et al.  Analysis on Design Standards for Energy Efficiency of Residential Buildings in Severe Cold and Cold Zones(JGJ26-2010) , 2012 .

[3]  M. Sherman,et al.  A mathematical model for infiltration heat recovery , 2000 .

[4]  Ekrem Laçin,et al.  Effect of Environmental Conditions in Poultry Houses on the Performance of Laying Hens , 2006 .

[5]  E A M Bokkers,et al.  Field study on effects of a heat exchanger on broiler performance, energy use, and calculated carbon dioxide emission at commercial broiler farms, and the experiences of farmers using a heat exchanger. , 2010, Poultry science.

[6]  Gerard Corkery,et al.  Monitoring environmental parameters in poultry production facilities , 2013 .

[7]  A. Gehad,et al.  Effect of heat stress on production parameters and immune responses of commercial laying hens. , 2004, Poultry science.

[8]  Baoming Li,et al.  Using CFD to assess the influence of ceiling deflector design on airflow distribution in hen house with tunnel ventilation , 2018, Comput. Electron. Agric..

[9]  Timothy A. Shepherd,et al.  Modelling ventilation rate, balance temperature and supplemental heat need in alternative vs. conventional laying-hen housing systems , 2013 .

[10]  Fangting Song,et al.  METEOROLOGICAL DATA SET FOR BUILDING THERMAL ENVIRONMENT ANALYSIS OF CHINA , 2007 .

[11]  Da Yan,et al.  DeST — An integrated building simulation toolkit Part I: Fundamentals , 2008 .

[12]  Thomas Bartzanas,et al.  Numerical study of mechanically ventilated broiler house equipped with evaporative pads , 2017, Comput. Electron. Agric..

[13]  E. Fabrizio,et al.  Climate control in broiler houses: A thermal model for the calculation of the energy use and indoor environmental conditions , 2018, Energy and Buildings.

[14]  Francesco Leccese,et al.  Ventilated facades energy performance in summer cooling of buildings , 2003 .

[15]  Girma Bitsuamlak,et al.  Air infiltration through building envelopes: A review , 2012 .

[16]  Xiaosong Zhang,et al.  DeST-based dynamic simulation and energy efficiency retrofit analysis of commercial buildings in the hot summer/cold winter zone of China: A case in Nanjing , 2014 .

[17]  Yang Wang,et al.  Optimising the design of confined laying hen house insulation requirements in cold climates without using supplementary heat , 2018, Biosystems Engineering.

[18]  J. C. Lam,et al.  Future trends of building heating and cooling loads and energy consumption in different climates , 2011 .

[19]  Li Qin,et al.  A MODIFIED HEAT RECOVERY VENTILATION SYSTEM FOR RABBIT HOUSES IN COLD CLIMATES IN NORTHEAST CHINA , 2016 .

[20]  Syahrul Nizam Kamaruzzaman,et al.  Achieving energy and cost savings through simple daylighting control in tropical historic buildings , 2015 .

[21]  Figen Balo,et al.  Effect of fuel type on the optimum thickness of selected insulation materials for the four different climatic regions of Turkey , 2009 .

[22]  Metin Olgun,et al.  Determining of heat balance design criteria for laying hen houses under continental climate conditions , 2007 .

[23]  Jacob H. Stang,et al.  Load prediction method for heat and electricity demand in buildings for the purpose of planning for mixed energy distribution systems , 2008 .

[24]  Robert F. Boehm,et al.  Passive building energy savings: A review of building envelope components , 2011 .

[25]  H. Madsen,et al.  Modelling the heat consumption in district heating systems using a grey-box approach , 2006 .

[26]  Peter V. Nielsen,et al.  An assessment of a partial pit ventilation system to reduce emission under slatted floor - Part 2: Feasibility of CFD prediction using RANS turbulence models , 2012 .

[27]  C. Donnelly,et al.  Chicken welfare is influenced more by housing conditions than by stocking density , 2004, Nature.

[28]  Zhen Li,et al.  Modelling and applications of annual energy-using simulation module of separated heat pipe heat exchanger , 2013 .