Abstract The PFNA was conceived by Sawa, Gozani and Ryge, in late 1987 as a means to achieve the highest possible sensitivity for detecting small amounts of explosives concealed in luggage. This could be attained because 1) all the elements present in explosives, i.e., O,N,C (and H, indirectly) can be measured via the (n,n′γ) process with fast neutrons, 2) using nanosecond pulses of neutrons and the time-of-flight (TOF) technique, a full direct imaging of the elements and hence all present materials can be obtained, and 3) the TOF assures the best signal to background ratio, as the signal-stimulated γ-rays are measured before the background — neutron interacting in the detector environment — arrives. The PFNA technology has made great strides since the autumn of 1987. It enables the detection of narcotics, explosives, many hazardous materials and most dutiable goods carried in trucks and containers.
[1]
Performance evaluation tools for nuclear based interrogation techniques — an application of the PFNA technology
,
1994
.
[2]
Z. Sawa.
PFN GASCA technique for detection of explosives and drugs
,
1993
.
[3]
F. Liu,et al.
Application of pulsed fast neutrons analysis to cargo inspection
,
1994
.
[4]
R. Loveman,et al.
Deficiencies in oxygen, carbon and chlorine (n, n′γ) cross sections and their impact on nuclear based inspection systems
,
1994
.
[5]
Tsahi Gozani,et al.
Novel applications of fast neutron interrogation methods
,
1994
.
[6]
Thomas J. Yule,et al.
Key research issues in the pulsed fast-neutron analysis technique for cargo inspection
,
1994,