High‐sensitivity single‐shot perfusion‐weighted fMRI †

A method is presented for measurement of perfusion changes during brain activation using a single‐shot pulsed spin labeling technique. By employing a double‐inversion labeling strategy, stationary tissue (background) signal was suppressed while minimally affecting perfusion sensitivity. This allowed omission of the otherwise required reference scan, resulting in twofold‐improved temporal resolution. The method was applied to visual and motor cortex activation studies in humans, and compared to standard FAIR‐type perfusion labeling techniques. Experiments performed at 1.5T and 3.0T indicate a close to 90% suppression of background signal, at a cost of an 11% and 9%, respectively, reduction in perfusion signal. Combined with the twofold increase in signal averaging, and a reduction in background signal fluctuations, this resulted in a 64% (1.5T, N = 3) and a 128% (3T, N = 4) overall improvement in sensitivity for the detection of activation‐related perfusion changes. Magn Reson Med 46:88–94, 2001. Published 2001 Wiley‐Liss, Inc.

[1]  Adrian T. Lee,et al.  Discrimination of Large Venous Vessels in Time‐Course Spiral Blood‐Oxygen‐Level‐Dependent Magnetic‐Resonance Functional Neuroimaging , 1995, Magnetic resonance in medicine.

[2]  D. Tank,et al.  4 Tesla gradient recalled echo characteristics of photic stimulation‐induced signal changes in the human primary visual cortex , 1993 .

[3]  Peter van Gelderen,et al.  A comparison of fast MR scan techniques for cerebral activation studies at 1.5 Tesla , 1998, Magnetic resonance in medicine.

[4]  T. L. Davis,et al.  Mr perfusion studies with t1‐weighted echo planar imaging , 1995, Magnetic resonance in medicine.

[5]  S. Ogawa Brain magnetic resonance imaging with contrast-dependent oxygenation , 1990 .

[6]  D. Weinberger,et al.  Noise reduction in 3D perfusion imaging by attenuating the static signal in arterial spin tagging (ASSIST) , 2000, Magnetic resonance in medicine.

[7]  D. Tank,et al.  Brain magnetic resonance imaging with contrast dependent on blood oxygenation. , 1990, Proceedings of the National Academy of Sciences of the United States of America.

[8]  R. Turner,et al.  Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation. , 1992, Proceedings of the National Academy of Sciences of the United States of America.

[9]  J H Duyn,et al.  Inflow versus deoxyhemoglobin effects in bold functional MRI using gradient echoes at 1.5 T , 1994, NMR in biomedicine.

[10]  Seong-Gi Kim Quantification of relative cerebral blood flow change by flow‐sensitive alternating inversion recovery (FAIR) technique: Application to functional mapping , 1995, Magnetic resonance in medicine.

[11]  G B Matson,et al.  Human brain infarction: proton MR spectroscopy. , 1992, Radiology.