Geotechnical Analysis of Heat Exchanger Piles

There is currently a lack of established calculation method for the geotechnical design of heat exchanger piles, although the technology is experiencing a fast expansion. Instead of quantifying the effects of temperature changes on the static behavior of heat exchanger piles, the common geotechnical practice is to apply a large overall security factor. This is done in order to be on the side of safety with respect to thermal effects. The few existing in situ experiments show that applying a thermal load induces a significant change in the stress-strain state of a pile. This paper presents a geotechnical numerical analysis method, based on the load transfer approach, which assesses the main effects of temperature changes on pile behavior. The method is validated on the basis of two in situ measurements of the loads and deformations experienced by heat exchanger test piles. The occurrence of critical design situations is further discussed. Some conclusions are formulated on concrete failure and the full mobilization of the pile shaft friction and base resistance during the operation of the heat exchange system.

[1]  Roger Frank,et al.  ESTIMATION PAR LES PARAMETRES PRESSIOMETRIQUES DE L'ENFONCEMENT SOUS CHARGE AXIALE DE PIEUX FORES DANS DES SOLS FINS , 1982 .

[2]  H. Bolton Seed,et al.  Closure of "The Action of Soft Clay along Friction Piles" , 1957 .

[3]  L. Laloui,et al.  Explaining thermal failure in saturated clays , 2009 .

[4]  Lymon C. Reese,et al.  Load Transfer for Axially Loaded Piles in Clay , 1966 .

[5]  A Bochon LES MESURES DE DEFORMATION DES STRUCTURES HYPERSTATIQUES : LE TEMOIN SONORE , 1992 .

[6]  K. Soga,et al.  Energy pile test at Lambeth College, London: geotechnical and thermodynamic aspects of pile response to heat cycles , 2009 .

[7]  L. Laloui,et al.  Experimental study of thermal effects on the mechanical behaviour of a clay , 2004 .

[8]  Hans-Jürgen Lang,et al.  Bodenmechanik und Grundbau , 1982 .

[9]  M. Randolph,et al.  Analysis of Deformation of Vertically Loaded Piles , 1978 .

[10]  L. Laloui,et al.  Non‐isothermal plasticity model for cyclic behaviour of soils , 2008 .

[11]  Chandrakant S. Desai,et al.  Load‐Deformation Response of Axially Loaded Piles , 1987 .

[12]  M. Moreni,et al.  Comportement d'un pieu bi-fonction, fondation et échangeur de chaleur , 2003 .

[13]  Ministere De L'equipement,et al.  Règles techniques de conception et de calcul des fondations des ouvrages de génie civil . Fascicule no 62 , 1993 .

[14]  N. Kalteziotis,et al.  Evaluation of Performance of Two Piles Using Pressuremeter Method , 1991 .

[15]  A. Marsland,et al.  Comparisons of the results from pressuremeter tests and large in situ plate tests in London Clay , 1977 .

[16]  Lyesse Laloui,et al.  Experimental and numerical investigations of the behaviour of a heat exchanger pile , 2006 .