Flow boiling heat transfer of carbon dioxide in horizontal mini tubes

Abstract Flow boiling heat transfer coefficients of carbon dioxide (CO 2 ) in mini tubes with inner diameters of 2.0 and 0.98 mm are measured and analyzed as a function of operating parameters. The heat transfer coefficients are measured at high mass fluxes from 500 to 3570 kg/m 2  s, heat fluxes from 7 to 48 kW/m 2 , and saturation temperatures of 0, 5 and 10 °C. The measured heat transfer coefficients before dryout are in the range of 10 000–20 000 W/m 2  K. The heat transfer coefficients before critical vapor quality are strongly affected by heat flux at all mass flux conditions. However, the effects of mass flux on heat transfer coefficients before critical vapor quality are only significant when the superficial liquid Weber number is less than 100. The heat transfer characteristics after critical vapor quality are explained by partially dried liquid film and rate of liquid droplets in the vapor core. Based on the database obtained from this study and the literature, a boiling heat transfer correlation before critical vapor quality is developed.

[1]  M. Cooper Heat Flow Rates in Saturated Nucleate Pool Boiling-A Wide-Ranging Examination Using Reduced Properties , 1984 .

[2]  V. M. Borishanskiĭ 3 – CORRELATION OF THE EFFECT OF PRESSURE ON THE CRITICAL HEAT FLUX AND HEAT TRANSFER RATES USING THE THEORY OF THERMODYNAMIC SIMILARITY , 1969 .

[3]  S. Y. Ahmad Fluid to fluid modeling of critical heat flux: A compensated distortion model , 1973 .

[4]  D. C. Groeneveld,et al.  Prediction of thermal non-equilibrium in the post-dryout regime , 1976 .

[5]  L. Tadrist,et al.  Pressure drop and heat transfer analysis of flow boiling in a minichannel: influence of the inlet condition on two-phase flow stability , 2004 .

[6]  Rin Yun,et al.  Critical quality prediction for saturated flow boiling of CO2 in horizontal small diameter tubes , 2003 .

[7]  E. Hihara,et al.  Boiling Heat Transfer of Carbon Dioxide in a Horizontal Tubes , 2005 .

[8]  M. W. Wambsganss,et al.  Two-phase flow patterns and transitions in a small, horizontal, rectangular channel , 1991 .

[9]  Rin Yun,et al.  Flow regimes for horizontal two-phase flow of CO2 in a heated narrow rectangular channel , 2004 .

[10]  R. Moffat Using Uncertainty Analysis in the Planning of an Experiment , 1985 .

[11]  M. W. Wambsganss,et al.  Two-phase pressure drop, boiling heat transfer, and critical heat flux to water in a small-diameter horizontal tube , 2002 .

[12]  P. Kew,et al.  Correlations for the prediction of boiling heat transfer in small-diameter channels , 1997 .

[13]  G. M. Lazarek,et al.  Evaporative heat transfer, pressure drop and critical heat flux in a small vertical tube with R-113 , 1982 .

[14]  J. P. Hartnett,et al.  Advances in Heat Transfer , 2003 .

[15]  Tsing-Fa Lin,et al.  Evaporation heat transfer and pressure drop of refrigerant R-134a in a small pipe , 1998 .

[16]  R. Winterton,et al.  A general correlation for saturated and subcooled flow boiling in tubes and annuli, based on a nucleate pool boiling equation , 1991 .

[17]  I. Mudawar,et al.  Flow boiling heat transfer in two-phase micro-channel heat sinks––I. Experimental investigation and assessment of correlation methods , 2003 .

[18]  Kunihito Matsumura,et al.  Saturated flow boiling of water in a vertical small diameter tube , 2003 .

[19]  D. Fletcher,et al.  Flow boiling heat transfer of Freon R11 and HCFC123 in narrow passages , 2000 .

[20]  M. W. Wambsganss,et al.  Boiling heat transfer with three fluids in small circular and rectangular channels , 1995 .

[21]  Jostein Pettersen,et al.  Flow vaporization of CO2 in microchannel tubes , 2004 .

[22]  Gad Hetsroni,et al.  Handbook of multiphase systems , 1982 .