Prediction of punching shear strength of HSC interior slab-column connections

Flat plate systems are widely used in reinforced concrete structures. Using of high-strength concrete has been common recently. In the current international codes of practice for concrete structures, the design methods for assessment of punching shear capacity are based on experimental data of flat plates with Normal-Strength Concrete (NSC). The aim of this research is to come up with new formula for punching shear resistance, consistent with data of flat plates made from High-Strength Concrete (HSC). Test results of 61 HSC interior slab-column connection specimens were collected from the literature. The available test results were not only compared with current code provisions but with equations proposed by other researchers as well. A new formula for predicting punching shear strength of HSC interior slab-column connections is proposed. An innovative design equation is also suggested.

[1]  M. Osman,et al.  BEHAVIOR OF HIGH-STRENGTH LIGHTWEIGHT CONCRETE SLABS UNDER PUNCHING LOADS , 2000 .

[2]  Lan Chung,et al.  Lessons from the Sampoong department store collapse , 2002 .

[3]  Walter H. Dilger,et al.  Critical review of the CSA A23.3-94 punching shear strength provisions for interior columns , 1996 .

[4]  Behavior of high-strength fibrous concrete slab–column connections under gravity and lateral loads , 2008 .

[5]  M. Polak,et al.  Retrofit of Slab Column Interior Connections Using Shear Bolts , 2005 .

[6]  Eivind Hognestad,et al.  Shearing Strength of Reinforced Concrete Slabs , 1956 .

[7]  Brahim Benmokrane,et al.  A New Punching Shear Equation for Two-Way Concrete Slabs Reinforced with FRP Bars , 2005, SP-230: 7th International Symposium on Fiber-Reinforced (FRP) Polymer Reinforcement for Concrete Structures.

[8]  N. Subramanian Evaluation and enhancing the punching shear resistance of flat slabs using HSC , 2005 .

[9]  Jonathan G. M. Wood,et al.  PIPERS ROW CAR PARK COLLAPSE: IDENTIFYING RISK , 2003 .

[10]  Gib Rankin,et al.  PREDICTING THE PUNCHING STRENGTH OF CONVENTIONAL SLAB-COLUMN SPECIMENS. , 1987 .

[11]  H. Marzouk,et al.  Experimental Investigation on Shear Enhancement Types for High-Strength Concrete Plates , 1997 .

[12]  Comite Euro-International du Beton,et al.  CEB-FIP Model Code 1990 , 1993 .

[13]  H Faghani Nobari,et al.  PUNCHING SHEAR RESISTANCE OF HIGH-STRENGTH CONCRETE SLABS , 2003 .

[14]  N. J. Gardner Relationship of the Punching Shear Capacity of Reinforced Concrete Slabs With Concrete Strength , 1990 .

[15]  H. Marzouk,et al.  Effect of High-Strength Concrete Slab on the Behavior of Slab-Column Connections , 1998 .

[16]  N. J. Gardner,et al.  Punching shear of continuous flat reinforced concrete slabs , 1996 .

[17]  H. Marzouk,et al.  Experimental Investigation on the Behavior of High-Strength Concrete Slabs , 1992 .

[18]  Arthur H. Nilson,et al.  Design of concrete structures , 1972 .