Optimization of sampling pattern and the design of Fourier ptychographic illuminator.

Fourier ptychography (FP) is a recently developed imaging approach that facilitates high-resolution imaging beyond the cutoff frequency of the employed optics. In the original FP approach, a periodic LED array is used for sample illumination, and therefore, the scanning pattern is a uniform grid in the Fourier space. Such a uniform sampling scheme leads to 3 major problems for FP, namely: 1) it requires a large number of raw images, 2) it introduces the raster grid artefacts in the reconstruction process, and 3) it requires a high-dynamic-range detector. Here, we investigate scanning sequences and sampling patterns to optimize the FP approach. For most biological samples, signal energy is concentrated at low-frequency region, and as such, we can perform non-uniform Fourier sampling in FP by considering the signal structure. In contrast, conventional ptychography perform uniform sampling over the entire real space. To implement the non-uniform Fourier sampling scheme in FP, we have designed and built an illuminator using LEDs mounted on a 3D-printed plastic case. The advantages of this illuminator are threefold in that: 1) it reduces the number of image acquisitions by at least 50% (68 raw images versus 137 in the original FP setup), 2) it departs from the translational symmetry of sampling to solve the raster grid artifact problem, and 3) it reduces the dynamic range of the captured images 6 fold. The results reported in this paper significantly shortened acquisition time and improved quality of FP reconstructions. It may provide new insights for developing Fourier ptychographic imaging platforms and find important applications in digital pathology.

[1]  Kaikai Guo,et al.  High-resolution fluorescence imaging via pattern-illuminated Fourier ptychography. , 2014, Optics express.

[2]  Jingjuan Zhang,et al.  Phase-retrieval algorithms applied in a 4-f system for optical image encryption: a comparison , 2005, SPIE/COS Photonics Asia.

[3]  J R Fienup,et al.  Reconstruction of an object from the modulus of its Fourier transform. , 1978, Optics letters.

[4]  Heinz H. Bauschke,et al.  Phase retrieval, error reduction algorithm, and Fienup variants: a view from convex optimization. , 2002, Journal of the Optical Society of America. A, Optics, image science, and vision.

[5]  Guoan Zheng,et al.  Adaptive system correction for robust Fourier ptychographic imaging. , 2013, Optics express.

[6]  Guoan Zheng,et al.  Quantitative phase imaging via Fourier ptychographic microscopy. , 2013, Optics letters.

[7]  Siyuan Dong,et al.  Spectral multiplexing and coherent-state decomposition in Fourier ptychographic imaging. , 2014, Biomedical optics express.

[8]  J. Rodenburg,et al.  An annealing algorithm to correct positioning errors in ptychography. , 2012, Ultramicroscopy.

[9]  W. Hoppe,et al.  Beugung in inhomogenen Primärstrahlenwellenfeld. II. Lichtoptische Analogieversuche zur Phasenmessung von Gitterinterferenzen , 1969 .

[10]  Kannan Ramchandran,et al.  Multiplexed coded illumination for Fourier Ptychography with an LED array microscope. , 2014, Biomedical optics express.

[11]  Qionghai Dai,et al.  Content adaptive illumination for Fourier ptychography. , 2014, Optics letters.

[12]  P. Ferraro,et al.  Breakthroughs in Photonics 2013: Holographic Imaging , 2014, IEEE Photonics Journal.

[13]  Siyuan Dong,et al.  Aperture-scanning Fourier ptychography for 3D refocusing and super-resolution macroscopic imaging. , 2014, Optics express.

[14]  Kaikai Guo,et al.  Microscopy illumination engineering using a low-cost liquid crystal display. , 2015, Biomedical optics express.

[15]  Xiaojing Huang,et al.  Optimization of overlap uniformness for ptychography. , 2014, Optics express.

[16]  Andreas Menzel,et al.  Probe retrieval in ptychographic coherent diffractive imaging. , 2009, Ultramicroscopy.

[17]  J. Rodenburg,et al.  Movable aperture lensless transmission microscopy: a novel phase retrieval algorithm. , 2004, Physical review letters.

[18]  Guoan Zheng,et al.  Fourier ptychographic microscopy for filtration-based circulating tumor cell enumeration and analysis , 2014, Journal of biomedical optics.

[19]  O. Bunk,et al.  Ptychographic coherent diffractive imaging of weakly scattering specimens , 2010 .

[20]  R. Horstmeyer,et al.  Wide-field, high-resolution Fourier ptychographic microscopy , 2013, Nature Photonics.

[21]  J. Rodenburg,et al.  An improved ptychographical phase retrieval algorithm for diffractive imaging. , 2009, Ultramicroscopy.

[22]  Kaikai Guo,et al.  Incoherent Fourier ptychographic photography using structured light , 2015 .

[23]  øöö Blockinø Phase retrieval, error reduction algorithm, and Fienup variants: A view from convex optimization , 2002 .

[24]  Guoan Zheng,et al.  Embedded pupil function recovery for Fourier ptychographic microscopy. , 2014, Optics express.

[25]  O. Bunk,et al.  High-Resolution Scanning X-ray Diffraction Microscopy , 2008, Science.

[26]  Kaikai Guo,et al.  FPscope: a field-portable high-resolution microscope using a cellphone lens. , 2014, Biomedical optics express.

[27]  J. Rodenburg Ptychography and Related Diffractive Imaging Methods , 2008 .

[28]  J. Fienup,et al.  Phase retrieval with transverse translation diversity: a nonlinear optimization approach. , 2008, Optics express.

[29]  R. Gerchberg A practical algorithm for the determination of phase from image and diffraction plane pictures , 1972 .