Effects of alveolar dead-space, shunt and V/Q distribution on respiratory dead-space measurements.

BACKGROUND Respiratory dead-space is often increased in lung disease. This study evaluates the effects of increased alveolar dead-space (Vd(alv)), pulmonary shunt, and abnormal ventilation perfusion ratio (/) distributions on dead-space and alveolar partial pressure of carbon dioxide (Pa(co(2))) calculated by various methods, assesses a recently published non-invasive method (Koulouris method) for the measurement of Bohr dead-space, and evaluates an equation for calculating physiological dead-space (Vd(phys)) in the presence of pulmonary shunt. METHODS Pulmonary shunt, / distribution and Vd(alv) were varied in a tidally breathing cardiorespiratory model. Respiratory data generated by the model were analysed to calculate dead-spaces by the Fowler, Bohr, Bohr-Enghoff and Koulouris methods. Pa(co(2)) was calculated by the method of Koulouris. RESULTS When Vd(alv) is increased, Vd(phys) can be recovered by the Bohr and Bohr-Enghoff equations, but not by the Koulouris method. Shunt increases the calculated Bohr-Enghoff dead-space, but does not affect Fowler, Bohr or Koulouris dead-spaces, or Vd(phys) estimated by the shunt-corrected equation if pulmonary artery catheterization is available. Bohr-Enghoff but not Koulouris or Fowler dead-space increases with increasing severity of / maldistribution. When alveolar Pco(2) is increased by any mechanism, Pa(co(2)) calculated by Koulouris' method does not agree well with average alveolar Pco(2). CONCLUSIONS Our studies show that increased pulmonary shunt causes an apparent increase in Vd(phys), and that abnormal / distributions affect the calculated Vd(phys) and Vd(alv), but not Fowler dead-space. Dead-space and Pa(co(2)) calculated by the Koulouris method do not represent true Bohr dead-space and Pa(co(2)) respectively, but the shunt-corrected equation performs well.

[1]  C. Bohr Ueber die Lungenathmung1 , 1891 .

[2]  W. S. Fowler Lung function studies; the respiratory dead space. , 1948, The American journal of physiology.

[3]  W. S. Fowler,et al.  Lung function studies. VI. Detection of uneven alveolar ventilation during a single breath of oxygen. , 1951, The American journal of medicine.

[4]  W. O. Fenn,et al.  Alveolar CO2 during the respiratory cycle. , 1952, Journal of applied physiology.

[5]  M. Scherrer,et al.  [Alveolar dead space]. , 1958, Helvetica medica acta.

[6]  H RAHN,et al.  Dynamics of changes in carbon dioxide stores. , 1960, Anesthesiology.

[7]  C. Carrington,et al.  Morphometry of the Human Lung , 1965, The Yale Journal of Biology and Medicine.

[8]  R. J. Lorenz Weibel, E. R.: Morphometry of the Human Lung. Springer Verlag, Berlin‐Göttingen‐Heidelberg 1963; 151 S., 109 Abb., DM 36,‐ , 1966 .

[9]  A. Olszowka,et al.  A system of digital computer subroutines for blood gas calculations. , 1968, Respiration physiology.

[10]  J. Troquet,et al.  [Alveolar dead space]. , 1969, Archives internationales de physiologie et de biochimie.

[11]  D. Duncalf,et al.  Effect of anatomic shunt on physiologic deadspace-to-tidal volume ratio--a new equation. , 1969, Anesthesiology.

[12]  N. Cherniack,et al.  Oxygen and carbon dioxide gas stores of the body. , 1970, Physiological reviews.

[13]  J. West,et al.  Ventilation-perfusion inequality in chronic obstructive pulmonary disease. , 1977, The Journal of clinical investigation.

[14]  N. Jones,et al.  Difference between end-tidal and arterial PCO2 in exercise. , 1979, Journal of applied physiology: respiratory, environmental and exercise physiology.

[15]  R Fletcher,et al.  The concept of deadspace with special reference to the single breath test for carbon dioxide. , 1981, British journal of anaesthesia.

[16]  J. Grønlund Errors due to tissue CO2 capacity in estimation of pulmonary blood flow from single-breath gas analysis. , 1983, Respiration physiology.

[17]  B. Jonson,et al.  Deadspace and the single breath test for carbon dioxide during anaesthesia and artificial ventilation. Effects of tidal volume and frequency of respiration. , 1984, British journal of anaesthesia.

[18]  H. Moseley,et al.  Arterial to end tidal carbon dioxide tension difference during Caesarean section anaesthesia , 1986, Anaesthesia.

[19]  A. B. Crawford,et al.  Effect of tidal volume on ventilation maldistribution. , 1986, Respiration Physiology.

[20]  R. Fletcher,et al.  Relationship between alveolar deadspace and arterial oxygenation in children with congenital cardiac disease. , 1989, British journal of anaesthesia.

[21]  W. Dick,et al.  Arterial and Mixed Venous Blood Gas Status during Apnoea of Intubation — Proof of the Christiansen-Douglas-Haldane Effect in Vivo , 1989, Anaesthesia and intensive care.

[22]  John F. Nunn,et al.  Nunn's Applied Respiratory Physiology , 1993 .

[23]  P. Breen,et al.  How does experimental pulmonary embolism decrease CO2 elimination? , 1996, Respiration physiology.

[24]  T Stijnen,et al.  Dead space and slope indices from the expiratory carbon dioxide tension-volume curve. , 1997, The European respiratory journal.

[25]  Olsson,et al.  Diagnosis of pulmonary embolism by measurement of alveolar dead space , 1998, Journal of internal medicine.

[26]  P. Cleaton-jones,et al.  Small tidal volume ventilation using a zero deadspace tracheal tube. , 1999, British journal of anaesthesia.

[27]  M. Rüdiger,et al.  Utility of deadspace and capnometry measurements in determination of surfactant efficacy in surfactant-depleted lungs. , 1999, Critical care medicine.

[28]  G. Schmalisch,et al.  In vitro and in vivo assessment of the Ventrak 1550/Capnogard 1265 for single breath carbon dioxide analysis in neonates. , 1999, British journal of anaesthesia.

[29]  I. Cheifetz,et al.  Deadspace to tidal volume ratio predicts successful extubation in infants and children , 2000, Critical care medicine.

[30]  R. Fletcher Nunn's Applied Respiratory Physiology, 5th Edn. , 2000 .

[31]  J. Dimitroulis,et al.  Noninvasive measurement of mean alveolar carbon dioxide tension and Bohr's dead space during tidal breathing. , 2001, The European respiratory journal.

[32]  J. Kline,et al.  Diagnostic accuracy of a bedside D-dimer assay and alveolar dead-space measurement for rapid exclusion of pulmonary embolism: a multicenter study. , 2001, JAMA.

[33]  Rian,et al.  PULMONARY DEAD-SPACE FRACTION AS A RISK FACTOR FOR DEATH IN THE ACUTE RESPIRATORY DISTRESS SYNDROME , 2002 .

[34]  M. Antonelli,et al.  Noninvasive vs. conventional mechanical ventilation in patients with chronic obstructive pulmonary disease after failure of medical treatment in the ward: a randomized trial , 2002, Intensive Care Medicine.

[35]  Jonathan G Hardman,et al.  Validation of an Original Mathematical Model of CO2 Elimination and Dead Space Ventilation , 2003, Anesthesia and analgesia.

[36]  M. J. Turner,et al.  Sources of Error in Noninvasive Pulmonary Blood Flow Measurements by Partial Rebreathing: A Computer Model Study , 2003, Anesthesiology.

[37]  Franck Verschuren,et al.  Volumetric capnography as a screening test for pulmonary embolism in the emergency department. , 2004, Chest.