Studies in RF Power Communication, SAR, and Temperature Elevation in Wireless Implantable Neural Interfaces

Implantable neural interfaces are designed to provide a high spatial and temporal precision control signal implementing high degree of freedom real-time prosthetic systems. The development of a Radio Frequency (RF) wireless neural interface has the potential to expand the number of applications as well as extend the robustness and longevity compared to wired neural interfaces. However, it is well known that RF signal is absorbed by the body and can result in tissue heating. In this work, numerical studies with analytical validations are performed to provide an assessment of power, heating and specific absorption rate (SAR) associated with the wireless RF transmitting within the human head. The receiving antenna on the neural interface is designed with different geometries and modeled at a range of implanted depths within the brain in order to estimate the maximum receiving power without violating SAR and tissue temperature elevation safety regulations. Based on the size of the designed antenna, sets of frequencies between 1 GHz to 4 GHz have been investigated. As expected the simulations demonstrate that longer receiving antennas (dipole) and lower working frequencies result in greater power availability prior to violating SAR regulations. For a 15 mm dipole antenna operating at 1.24 GHz on the surface of the brain, 730 uW of power could be harvested at the Federal Communications Commission (FCC) SAR violation limit. At approximately 5 cm inside the head, this same antenna would receive 190 uW of power prior to violating SAR regulations. Finally, the 3-D bio-heat simulation results show that for all evaluated antennas and frequency combinations we reach FCC SAR limits well before 1 °C. It is clear that powering neural interfaces via RF is possible, but ultra-low power circuit designs combined with advanced simulation will be required to develop a functional antenna that meets all system requirements.

[1]  G. Lazzi,et al.  Investigation of a microwave data telemetry link for a retinal prosthesis , 2004, IEEE Transactions on Microwave Theory and Techniques.

[2]  John C. Batchelor,et al.  Antennas and Propagation for Body-Centric Wireless Communications , 2012 .

[3]  Jon A. Mukand,et al.  Neuronal ensemble control of prosthetic devices by a human with tetraplegia , 2006, Nature.

[4]  Gang Kang,et al.  SARs for pocket-mounted mobile telephones at 835 and 1900 MHz. , 2002, Physics in medicine and biology.

[5]  A. Kiourti,et al.  A Review of Implantable Patch Antennas for Biomedical Telemetry: Challenges and Solutions [Wireless Corner] , 2012, IEEE Antennas and Propagation Magazine.

[6]  José Carlos Príncipe,et al.  Florida Wireless Implantable Recording Electrodes (FWIRE) for Brain Machine Interfaces , 2007, 2007 IEEE International Symposium on Circuits and Systems.

[7]  Jean-Pierre Berenger,et al.  A perfectly matched layer for the absorption of electromagnetic waves , 1994 .

[8]  P.S. Hall,et al.  Antennas and propagation for body centric wireless communications , 2012, IEEE/ACES International Conference on Wireless Communications and Applied Computational Electromagnetics, 2005..

[9]  J. Lahtinen,et al.  A coaxial probe feed model for FDTD , 2002 .

[10]  A. Schwartz,et al.  Behavioral and neural correlates of visuomotor adaptation observed through a brain-computer interface in primary motor cortex. , 2012, Journal of neurophysiology.

[11]  Miguel A. L. Nicolelis,et al.  Actions from thoughts , 2001, Nature.

[12]  Ada S. Y. Poon,et al.  Implantable biomedical devices: Wireless powering and communication , 2012, IEEE Communications Magazine.

[13]  Lin Tang,et al.  Electromagnetic and modeling analyses of an implanted device at 3 and 7 Tesla , 2007, Journal of magnetic resonance imaging : JMRI.

[14]  John P. Cunningham,et al.  A High-Performance Neural Prosthesis Enabled by Control Algorithm Design , 2012, Nature Neuroscience.

[15]  Jason P Fine,et al.  Microwave ablation with loop antenna: in vivo porcine liver model. , 2004, Radiology.

[16]  C. Rappaport,et al.  A 2 1/4-turn spiral antenna for catheter cardiac ablation , 1999, IEEE Transactions on Biomedical Engineering.

[17]  John P. Donoghue,et al.  Connecting cortex to machines: recent advances in brain interfaces , 2002, Nature Neuroscience.

[18]  James C. Lin,et al.  A new IEEE standard for safety levels with respect to human exposure to radio-frequency radiation , 2006 .

[19]  Jerald D. Kralik,et al.  Real-time prediction of hand trajectory by ensembles of cortical neurons in primates , 2000, Nature.

[20]  L. Ukkonen,et al.  Design of Wireless Links to Implanted Brain–Machine Interface Microelectronic Systems , 2012, IEEE Antennas and Wireless Propagation Letters.

[21]  Robert L. Rennaker,et al.  Implantable radio frequency identification sensors: Wireless power and communication , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  G. Lazzi,et al.  Thermal effects of bioimplants , 2005, IEEE Engineering in Medicine and Biology Magazine.

[23]  Rajesh P. N. Rao,et al.  Control of a humanoid robot by a noninvasive brain–computer interface in humans , 2008, Journal of neural engineering.

[24]  O. Gandhi,et al.  Numerical simulation of annular-phased arrays of dipoles for hyperthermia of deep-seated tumors , 1992, IEEE Transactions on Biomedical Engineering.

[25]  S. C. DeMarco,et al.  Computed SAR and thermal elevation in a 0.25-mm 2-D model of the human eye and head in response to an implanted retinal stimulator - part I: models and methods , 2003 .

[26]  James C. Lin,et al.  SAR and temperature: Simulations and comparison to regulatory limits for MRI , 2007, Journal of magnetic resonance imaging : JMRI.

[27]  Niels Birbaumer,et al.  fMRI Brain-Computer Interface: A Tool for Neuroscientific Research and Treatment , 2007, Comput. Intell. Neurosci..

[28]  Arto Nurmikko,et al.  An implantable wireless neural interface for recording cortical circuit dynamics in moving primates , 2013, Journal of neural engineering.

[29]  Constantine A. Balanis,et al.  Antenna Theory: Analysis and Design , 1982 .

[30]  S. C. DeMarco,et al.  Computed SAR and Thermal Elevation in a 0 . 25-mm 2-D Model of the Human Eye and Head in Response to an Implanted Retinal Stimulator — Part I : Models and Methods , 2001 .

[31]  Alayar Kangarlu,et al.  Design and performance issues of RF coils utilized in ultra high field MRI: experimental and numerical evaluations , 2005, IEEE Transactions on Biomedical Engineering.

[32]  Eric Chow,et al.  Implantable RF Medical Devices: The Benefits of High-Speed Communication and Much Greater Communication Distances in Biomedical Applications , 2013, IEEE Microwave Magazine.

[33]  L. Del Castillo,et al.  A miniaturized neuroprosthesis suitable for implantation into the brain , 2003, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[34]  Y. Rahmat-Samii,et al.  Implanted antennas inside a human body: simulations, designs, and characterizations , 2004, IEEE Transactions on Microwave Theory and Techniques.

[35]  R.R. Harrison,et al.  Wireless Neural Recording With Single Low-Power Integrated Circuit , 2009, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[36]  Miguel A. L. Nicolelis,et al.  Real-time control of a robot arm using simultaneously recorded neurons in the motor cortex , 1999, Nature Neuroscience.

[37]  T. Ibrahim,et al.  Analysis of B1 field profiles and SAR values for multi-strut transverse electromagnetic RF coils in high field MRI applications. , 2001, Physics in medicine and biology.

[38]  S. Pisa,et al.  Distribution of SAR and temperature elevation induced in a phantom by a microwave cardiac ablation catheter , 2004, IEEE Transactions on Microwave Theory and Techniques.

[39]  C. Rappaport,et al.  Cardiac tissue ablation with catheter-based microwave heating , 2004, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[40]  Tamer S. Ibrahim,et al.  Understanding and manipulating the RF fields at high field MRI , 2009, NMR in biomedicine.

[41]  Thomas Neuberger,et al.  Experimental and numerical assessment of MRI‐induced temperature change and SAR distributions in phantoms and in vivo , 2010, Magnetic resonance in medicine.

[42]  F. Mussa-Ivaldi,et al.  Brain–machine interfaces: computational demands and clinical needs meet basic neuroscience , 2003, Trends in Neurosciences.

[43]  T. Meng,et al.  Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue , 2010, IEEE Transactions on Antennas and Propagation.

[44]  R. Rennaker,et al.  Electromagnetic Power Absorption and Temperature Changes due to Brain Machine Interface Operation , 2007, Annals of Biomedical Engineering.

[45]  Nicolas Y. Masse,et al.  Reach and grasp by people with tetraplegia using a neurally controlled robotic arm , 2012, Nature.

[46]  Felix A. Miranda,et al.  Analysis of Electromagnetic Fields Induced in Operation of a Wireless Fully Passive Backscattering Neurorecording Microsystem in Emulated Human Head Tissue , 2013, IEEE Transactions on Microwave Theory and Techniques.

[47]  James G. Maloney,et al.  A simple FDTD model for transient excitation of antennas by transmission lines , 1994 .

[48]  Nominations from FDA’s Center from Device and Radiological Health Radio Frequency Radiation Emissions of Wireless Communication Devices (CDRH) , 2000 .

[49]  D. Cheng Field and wave electromagnetics , 1983 .

[50]  R. Normann,et al.  Thermal Impact of an Active 3-D Microelectrode Array Implanted in the Brain , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[51]  T. Ibrahim,et al.  Dielectric resonances and B(1) field inhomogeneity in UHFMRI: computational analysis and experimental findings. , 2001, Magnetic resonance imaging.

[52]  Miguel A. L. Nicolelis,et al.  Brain–machine interfaces: past, present and future , 2006, Trends in Neurosciences.

[53]  A. Schwartz,et al.  High-performance neuroprosthetic control by an individual with tetraplegia , 2013, The Lancet.

[54]  Chen-To Tai,et al.  Radiation of a Hertzian dipole immersed in a dissipative medium , 2000 .

[55]  S. Coyle,et al.  Brain–computer interfaces: a review , 2003 .

[56]  T. Ibrahim,et al.  Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator. , 2001, Magnetic resonance imaging.