A novel vortex-assisted liquid-liquid microextraction approach using auxiliary solvent: Determination of iodide in mineral water samples.

A novel vortex-assisted liquid-liquid microextraction (VA-LLME) for determination of iodide was developed. The method includes the oxidation of iodide with iodate in the presence of hydrochloric acid followed by VA-LLME of the ion-pair formed between ICl2(-) and Astra Phloxine reagent (AP) and subsequent absorbance measurement at 555nm. The appropriate experimental conditions were investigated and found to be: 5mL of sample, 0.27molL(-)(1) HCl, 0.027mmolL(-1) KIO3 as the oxidation agent, 250μL of extraction mixture containing amyl acetate as the extraction solvent and carbon tetrachloride as the auxiliary solvent (1:1, v/v), 0.04mmolL(-1) AP reagent, vortex time: 20s at 3000rpm, centrifugation: 4min at 3000rpm. The calibration plot was linear in the range 16.9-169μg L(-1) of iodide, with a correlation coefficient (R(2)) of 0.996, and the relative standard deviation ranged from 1.9 to 5.7%. The limit of detection (LOD) and limit of quantification (LOQ) were 1.75 and 6.01μgL(-)(1) of iodide, respectively. The suggested procedure was applied for determination of iodide in real mineral water samples.

[1]  Rafael Cela,et al.  Ultrasound-assisted emulsification-microextraction of emergent contaminants and pesticides in environmental waters. , 2008, Journal of chromatography. A.

[2]  N. Gros Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples , 2013 .

[3]  Nicolas Kalogerakis,et al.  Vortex-assisted liquid-liquid microextraction of octylphenol, nonylphenol and bisphenol-A. , 2010, Talanta.

[4]  M. A. Al-hajjaji Spectrophotometric and spectrofluorimetric determination of iodide by extraction of ICl−2 with rhodamine B , 1987 .

[5]  J. Posta,et al.  A novel approach in dispersive liquid-liquid microextraction based on the use of an auxiliary solvent for adjustment of density UV-VIS spectrophotometric and graphite furnace atomic absorption spectrometric determination of gold based on ion pair formation. , 2010, Talanta.

[6]  F. Pena-Pereira,et al.  Headspace single-drop microextraction coupled to microvolume UV-vis spectrophotometry for iodine determination. , 2009, Analytica chimica acta.

[7]  M. Rezaee,et al.  Determination of organic compounds in water using dispersive liquid-liquid microextraction. , 2006, Journal of chromatography. A.

[8]  W. Hurst,et al.  HPLC Determination of Iodide in Scrum Using Paired Ion Chromatography with Electrochemical Detection , 1984 .

[9]  M. Fisichella,et al.  High-throughput dispersive liquid/liquid microextraction (DLLME) method for the rapid determination of drugs of abuse, benzodiazepines and other psychotropic medications in blood samples by liquid chromatography–tandem mass spectrometry (LC-MS/MS) and application to forensic cases , 2015 .

[10]  T. Kaiho Iodine Chemistry and Applications , 2014 .

[11]  D. L. Cason,et al.  Stability of the Chloro-complexes of Iodine in Aqueous Solution1 , 1961 .

[12]  P. Viñas,et al.  Kinetic determination of iodide, based on the chlorpromazine-bromate reaction. , 1987, Talanta.

[13]  N. Sharma,et al.  Liquid-phase microextraction and fibre-optics-based cuvetteless CCD-array micro-spectrophotometry for trace analysis. , 2009, Analytica chimica acta.

[14]  S. Ferreira,et al.  Determination of phosphorus, sulfur and the halogens using high-temperature molecular absorption spectrometry in flames and furnaces--A review. , 2009, Analytica chimica acta.

[15]  Ho‐Sang Shin,et al.  Trace level determination of iodide, iodine and iodate by gas chromatography-mass spectrometry , 1996 .

[16]  R. W. Ramette,et al.  Triiodide ion formation equilibrium and activity coefficients in aqueous solution , 1984 .

[17]  Y. Yamini,et al.  Ultrasound-assisted emulsification microextraction method based on applying low density organic solvents followed by gas chromatography analysis for the determination of polycyclic aromatic hydrocarbons in water samples. , 2009, Journal of chromatography. A.

[18]  Archana Jain,et al.  Single drop microextraction or solid phase microextraction-gas chromatography-mass spectrometry for the determination of iodine in pharmaceuticals, iodized salt, milk powder and vegetables involving conversion into 4-iodo-N,N-dimethylaniline. , 2004, Journal of chromatography. A.

[19]  P. Ugo,et al.  Nanoelectrode ensembles for the direct voltammetric determination of trace iodide in water , 2010 .

[20]  Supalax Srijaranai,et al.  Alternative solvent-based methyl benzoate vortex-assisted dispersive liquid-liquid microextraction for the high-performance liquid chromatographic determination of benzimidazole fungicides in environmental water samples. , 2014, Journal of separation science.

[21]  Łukasz Marcinkowski,et al.  Green aspects, developments and perspectives of liquid phase microextraction techniques. , 2014, Talanta.

[22]  A. Canals,et al.  Dispersive liquid–liquid microextraction combined with laser-induced breakdown spectrometry and inductively coupled plasma optical emission spectrometry to elemental analysis , 2015 .

[23]  Fatima Zohra Abouhiat,et al.  A miniaturized analyzer for the catalytic determination of iodide in seawater and pharmaceutical samples. , 2013, Talanta.

[24]  M. Farajzadeh,et al.  Dispersive liquid-liquid microextraction using extraction solvent lighter than water. , 2009, Journal of separation science.

[25]  Archana Jain,et al.  Recent advances in applications of single-drop microextraction: a review. , 2011, Analytica chimica acta.

[26]  Shahida B. Niazi,et al.  Spectrophotometric determination of traces of iodide by liquid—liquid extraction of Brilliant Green—iodide ion pair , 1991 .

[27]  Jana Šandrejová,et al.  Recent advances in dispersive liquid–liquid microextraction using organic solvents lighter than water. A review , 2012 .

[28]  Archana Jain,et al.  Liquid-phase microextraction-gas chromatography-mass spectrometry for the determination of bromate, iodate, bromide and iodide in high-chloride matrix. , 2007, Journal of chromatography. A.

[29]  Juliano S Barin,et al.  Analytical methods for the determination of halogens in bioanalytical sciences: a review , 2013, Analytical and Bioanalytical Chemistry.

[30]  M. Kaykhaii,et al.  Comparison of two novel in-syringe dispersive liquid-liquid microextraction techniques for the determination of iodide in water samples using spectrophotometry. , 2014, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[31]  A. Ghiasvand,et al.  Development of a simple device for dispersive liquid-liquid microextraction with lighter than water organic solvents: isolation and enrichment of glycyrrhizic acid from licorice. , 2009, Analytica chimica acta.

[32]  Jingchan Zhao,et al.  Reverse flow injection spectrophotometric determination of iodate and iodide in table salt. , 2004, Talanta.

[33]  B. Buszewski,et al.  Microextraction sample preparation techniques in biomedical analysis. , 2014, Journal of separation science.

[34]  E. Safaei,et al.  Optimization of Auxiliary Solvent Demulsification Microextraction for Determination of Cyanide in Environmental Water and Biological Samples by Microvolume UV-Vis Spectrophotometry , 2015 .

[35]  Xiaolin Hou,et al.  A review on speciation of iodine-129 in the environmental and biological samples. , 2009, Analytica chimica acta.

[36]  N. Campillo,et al.  Recent achievements in solidified floating organic drop microextraction , 2015 .

[37]  Mohammad Rezaee,et al.  Evolution of dispersive liquid-liquid microextraction method. , 2010, Journal of chromatography. A.

[38]  M. Valcárcel,et al.  Use of switchable hydrophilicity solvents for the homogeneous liquid-liquid microextraction of triazine herbicides from environmental water samples. , 2015, Journal of Separation Science.

[39]  A. Timerbaev,et al.  Trace ion analysis of seawater by capillary electrophoresis: Determination of iodide using transient isotachophoretic preconcentration , 2003, Electrophoresis.

[40]  M. El-Shahawi,et al.  Spectrophotometric determination of periodate or iodate ions by liquid-liquid extraction as an ion-pair using tetramethylammonium iodide. , 1996, Talanta.

[41]  Jean-Michel Kauffmann,et al.  Highly sensitive determination of iodide by ion chromatography with amperometric detection at a silver-based carbon paste electrode. , 2008, Talanta.

[42]  R. Singhal,et al.  Health Risk Assessment for Bromate (BrO 3 – ) Traces in Ozonated Indian Bottled Water , 2011 .

[43]  Archana Jain,et al.  Salt-assisted liquid–liquid microextraction for the determination of iodine in table salt by high-performance liquid chromatography-diode array detection , 2011 .

[44]  A. S. Yazdi,et al.  Simultaneous derivatization and extraction of iodine from milk samples by hollow fiber liquid-phase microextraction followed by gas chromatography-electron capture detection , 2013, Journal of the Iranian Chemical Society.

[45]  Leo M.L. Nollet,et al.  Handbook of Water Analysis , 2013 .

[46]  Chien-chang Lin,et al.  Reassessment of Reactor Coolant and Iodine Chemistry under Accident Conditions , 2009 .

[47]  M. Urbánek,et al.  Determination of iodide in samples with complex matrices by hyphenation of capillary isotachophoresis and zone electrophoresis , 2007, Electrophoresis.